Illustration 1 g01124208
Schematic of the lift/tilt kickout set switch
This switch is a momentary contact double-pole, double throw switch connected to two switch-to-ground inputs of the ECM. The inputs to the ECM are normally open. This diagnostic code is recorded when the status of both the inputs to the ECM are grounded at the same time.The possible causes of this diagnostic code are listed:
The Lift/Lower input is shorted to ground while the Tilt input is grounded through the switch.
The circuits are shorted to ground in the harness.
The circuits are shorted together. The switch must be in one specific position.
The switch has failed.System Response:The machine response is listed:
The operator switch will not change the lift/lower or tilt kickout position.Note: Table 1 contains connector contacts. Use this information to troubleshoot the failed circuit.
Table 1
Lift/Tilt Kickout Set Switch Status
Switch Position J1-19
Lift/Lower KO Set Switch J1-20
Bucket KO Set Switch
Neutral Open Open
Tilt Kickout Set Open Closed
Lift Kickout Set Closed Open Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected.Note: Ensure that the diagnostic code indicator is active and that the diagnostic code is active.Test Step 1. CHECK THE SWITCH.
Observe ON/OFF status of the diagnostic code indicator.
Disconnect the connector of the switch from the harness. Expected Result:The diagnostic code indicator remains active.Results:
YES - The diagnostic code indicator remains active. The switch is not the cause of the diagnostic code. Proceed to test step 2.
NO - The diagnostic code indicator is inactive. The switch has failed or the harness has failed.Repair: Repeat this test in order to verify the failure of the switch. Repair the switch or replace the switch. Repair the harness or replace the harness.STOPTest Step 2. CHECK THE HARNESS CIRCUIT.
This test checks the continuity of the entire harness circuit that has failed. This test includes the switch that was previously checked.
Turn the disconnect switch to the OFF position.
Reconnect the switch that was disconnected in the previous step.
Disconnect the harness from the ECM.
Activate the switch. At the harness connector for the ECM, check the continuity to ground of both normally open contacts. Expected Result:The continuity agrees with Table 1.Results:
YES - The continuity agrees with the values in the preceding table. The harness circuit is correct.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this troubleshooting procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The continuity check DOES NOT agree with values in the preceding table.Repair: The harness circuit has failed. There is a short to ground in the harness between the ECM and the switch. Repair the harness or replace the harness.STOP
Parts software Caterpillar catalog:
3095776
SOFTWARE GP-
Caterpillar
Caterpillar
3095758
SOFTWARE GP-
Caterpillar
Caterpillar
3095756
SOFTWARE GP-
Caterpillar
Caterpillar
3095729
SOFTWARE GP-
Caterpillar
Caterpillar
3095727
SOFTWARE GP-
Caterpillar
Caterpillar
3095725
SOFTWARE GP-
Caterpillar
Caterpillar
3095830
SOFTWARE GP-
Caterpillar
Caterpillar
3095824
SOFTWARE GP-
Caterpillar
Caterpillar
3095816
SOFTWARE GP-
Caterpillar
Caterpillar
3095814
SOFTWARE GP-
Caterpillar
Caterpillar
3095811
SOFTWARE GP-
Caterpillar
Caterpillar
3095810
SOFTWARE GP-
Caterpillar
Caterpillar