2958128 SOLENOID Caterpillar parts
Rating:
Alternative (cross code) number:
CA2958128
295-8128
2958128
CA2958128
295-8128
2958128
Weight: 0.38 pounds 0 kg.
Information:
Illustration 1 g02034297
Schematic of the "Travel Straight" Solenoid
This diagnostic code is associated with the "Travel Straight" Solenoid. The FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above normal.The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The solenoid energizer circuit of the modulating valve is shorted to the +battery circuit.
The Machine ECM has failed but is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1525 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the Machine ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-43 (wire M740-PK(Pink)) to all contacts that are used in the machine harness connectors for the Machine ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-43 (M740-PK(Pink)) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1525 FMI 03 diagnostic code is active. Expected Result:The CID 1525 FMI 03 diagnostic code is active.Results:
YES - The CID 1525 FMI 03 diagnostic code is active. The problem has not been corrected. The Machine ECM may have failed.Repair: Is unlikely that the Machine ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1525 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection that was resolved when a harness connector was disconnected and reconnected. Resume normal machine operation.STOP
Parts solenoid Caterpillar catalog:
2943218
SOLENOID-VALVE
Caterpillar
Caterpillar
2834690
SOLENOID
Caterpillar
Caterpillar
2785527
SOLENOID AS-
Caterpillar
Caterpillar
2769585
SOLENOID GP-
Caterpillar
Caterpillar
2739650
SOLENOID VALVE
Caterpillar
Caterpillar
2713089
SOLENOID GP -
Caterpillar
Caterpillar
2I7335
SOLENOID
Caterpillar
Caterpillar
2I7100
SOLENOID
Caterpillar
Caterpillar
2I5399
SOLENOID VLV
Caterpillar
Caterpillar
2I5063
SOLENOID
Caterpillar
Caterpillar
2978495
SOLENOID
Caterpillar
Caterpillar
2970736
SOLENOID
Caterpillar
Caterpillar