Information:
Illustration 1 g01923084
Schematic of the "Stick Cylinder Retract" solenoid
This diagnostic code is associated with the "Stick Cylinder Retract" solenoid. The FMI 05 diagnostic code means that the ECM has determined that an open in the circuit exists. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. A failure of the Machine ECM is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1140 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire K928-GN(Green)) to contact 2 (wire K927-BU(Blue)).
Observe the status of the CID 1140 FMI 05 diagnostic code. Expected Result:The CID 1140 FMI 05 diagnostic code remains active. Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-40 (wire K928-GN(Green)) to contact J2-19 (wire K927-BU(Blue)). Expected Result:The resistance is less than 5 ohms.Results:
OK - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire K928-GN(Green) or in wire K927-BU(Blue) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1140 FMI 05 diagnostic code. Expected Result:The CID 1140 FMI 05 diagnostic code is active. Results:
YES - The CID 1140 FMI 05 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: A failure of the ECM is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is
Caterpillar parts catalog:
Parts solenoid Caterpillar catalog:
7C9458
SOLENOID GP-SHUTOFF
3114, 3116, 3126, 550, 570, 574, 580, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434
3114, 3116, 3126, 550, 570, 574, 580, AP-1000B, AP-1055B, AP-900B, BG-2455C, BG-245C, CB-434
9X5524
SOLENOID AS
205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 320 L, 325 LN, 613C, 910E, 950F, CB-434, CP-563, D250D, E200B, IT12B, IT14B
205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 320 L, 325 LN, 613C, 910E, 950F, CB-434, CP-563, D250D, E200B, IT12B, IT14B
7C4028
SOLENOID GP-SHUTOFF
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 3126, 320 L, 320B, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 322C FM, 325, 325 L, 325 LN, 325B, 3...
120H, 120H ES, 120H NA, 135H, 135H NA, 205B, 206B, 211B, 212B, 213B, 214B, 224B, 3114, 3116, 3126, 320 L, 320B, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 322C FM, 325, 325 L, 325 LN, 325B, 3...
7X1955
SOLENOID AS
214B, 3116, E240C
214B, 3116, E240C
6T4124
SOLENOID
3208
3208
4448241
SOLENOID
3512, 3512B
3512, 3512B
3802679
SOLENOID
C1.5, C2.2, CB22B, CB24B, CB32B, CB34B, CB34B XW, CC24B, CC34B
C1.5, C2.2, CB22B, CB24B, CB32B, CB34B, CB34B XW, CC24B, CC34B
2427979
SOLENOID AS
3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, 3606, C175-16, C175-20
3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, 3606, C175-16, C175-20
3653339
SOLENOID
3011C, 3013C, C1.5, C1.6, C2.2, CB-14, CB-334E
3011C, 3013C, C1.5, C1.6, C2.2, CB-14, CB-334E
1631547
SOLENOID
3306, 3306C, 3406B, 3406C
3306, 3306C, 3406B, 3406C
2Y8068
SOLENOID-SHUT-OFF
3304, 3304B, 3306, 3306B
3304, 3304B, 3306, 3306B
8C3663
SOLENOID AS-MAGNETIC
214B, 325, 325 LN, 325B, 613C, 950G
214B, 325, 325 LN, 325B, 613C, 950G
6T4122
SOLENOID
3304, 375, 916, 936, 950B, 966D, 966F, 980F, D250B, D25C, D300B, D30C, D350C, D35C
3304, 375, 916, 936, 950B, 966D, 966F, 980F, D250B, D25C, D300B, D30C, D350C, D35C
7T2007
SOLENOID
3114, 3116
3114, 3116