0019422 SPACER Caterpillar parts
Rating:
Alternative (cross code) number:
CA0019422
001-9422
0019422
CA0019422
001-9422
0019422
Weight: 0.80 pounds 0 kg.
Information:
Illustration 1 g01376568
Connections of the blade angle right solenoidThis diagnostic code is associated with the blade angle right solenoid. The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1934 FMI 06 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The FMI 06 changes to FMI 05 after the solenoid is disconnected.Results:
YES - The FMI 06 changes to FMI 05 after the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J1-66 (wire 752-YL) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-66 (wire 752-YL) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the diagnostic code.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active. The diagnostic code has not been corrected.Repair: Check the circuit again. It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Prior to replacing an ECM,
Parts spacer Caterpillar catalog:
0019417
SPACER
Caterpillar
Caterpillar
0019063
SPACER
Caterpillar
Caterpillar
0019040
SPACER
Caterpillar
Caterpillar
0018935
SPACER
Caterpillar
Caterpillar
0018583
SPACER
Caterpillar
Caterpillar
0018529
SPACER
Caterpillar
Caterpillar
0021415
SPACER
Caterpillar
Caterpillar
0021413
SPACER
Caterpillar
Caterpillar
0021194
SPACER
Caterpillar
Caterpillar
0021097
SPACER
Caterpillar
Caterpillar
0020705
SPACER
Caterpillar
Caterpillar
0020428
SPACER
Caterpillar
Caterpillar