2212616 SPACER Caterpillar parts
773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777C, 777D, 777F, 777G, 844H, 844K, 854K, 990H, 990K, 992K, 993K, AD55B, AD60, C27, C32, CX35-P800, D10N, D10R, D10T, D10T2, D11R, D11T,...
Rating:
Alternative (cross code) number:
CA2212616
221-2616
2212616
CA2212616
221-2616
2212616
Weight: 0.20 pounds 0 kg.
GENERATOR SET, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2212616:
Information:
System Operation Description:This procedure checks for an open circuit or a short circuit in a Data Link. There are three data links associated with the EMCP 4.
Accessory CAN Data Link
Primary CAN Data Link
Modbus RS-485 SCADA Data Link Refer to Systems Operation, "General Information" for details on each data link. Note: Use the wiring diagram for your particular genset in order to troubleshoot the Data Links.Test Step 1. INSPECT THE ELECTRICAL CONNECTORS AND THE WIRING
Turn the keyswitch to the OFF position.
Thoroughly inspect the EMCP 4 connector, the service tool connector, and all other connectors in the circuit for the data link. Reference: Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - In order to troubleshoot the Modbus RS-485 SCADA Data Link, proceed to Test Step 2
OK - In order to troubleshoot the Primary CAN or the Accessory CAN Data Link, proceed to Test Step 4
Not OK - Repair: Repair the wiring or replace the wiring.STOPTest Step 2. CHECK FOR SHORTS IN THE MODBUS RS-485 SCADA DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Measure the resistance between (data link +) and data link -).
Measure the resistance between ( data link +) and chassis ground.
Measure the resistance between ( data link -) and chassis ground. Expected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - Proceed to Test Step 5
Not OK - There is a short circuit in the harness or connectors.Repair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 3. CHECK THE RESISTANCE THROUGH THE MODBUS RS-485 SCADA DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Use a suitable piece of wire to short (Data Link +) and ( Data Link -) at the EMCP 4.
Measure the resistance between (Data Link +) and (Data Link -) at all other connectors in the circuit for the data link. Expected Result:The resistance is less than 10 Ohms.Results:
OK - The Data Link is OK. Proceed to test step 5
Not OK - There is an open circuit or excessive resistance in the harness or connectors.Repair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 4. CHECK FOR SHORTS IN THE CAN DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Measure the resistance between (data link +) and data link -). Expected Result:The resistance is approximately 60 Ohms.Results:
OK - Proceed to Test Step 5.
Not OK - If the resistance is approximately 120 ohms, a termination resistor is missing. If the resistance is much greater than 120 ohms, both termination resistors are missing or there is an open data link circuit. if the resistance is much less than 60 ohms, there is a short circuitRepair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 5. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the
Accessory CAN Data Link
Primary CAN Data Link
Modbus RS-485 SCADA Data Link Refer to Systems Operation, "General Information" for details on each data link. Note: Use the wiring diagram for your particular genset in order to troubleshoot the Data Links.Test Step 1. INSPECT THE ELECTRICAL CONNECTORS AND THE WIRING
Turn the keyswitch to the OFF position.
Thoroughly inspect the EMCP 4 connector, the service tool connector, and all other connectors in the circuit for the data link. Reference: Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - In order to troubleshoot the Modbus RS-485 SCADA Data Link, proceed to Test Step 2
OK - In order to troubleshoot the Primary CAN or the Accessory CAN Data Link, proceed to Test Step 4
Not OK - Repair: Repair the wiring or replace the wiring.STOPTest Step 2. CHECK FOR SHORTS IN THE MODBUS RS-485 SCADA DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Measure the resistance between (data link +) and data link -).
Measure the resistance between ( data link +) and chassis ground.
Measure the resistance between ( data link -) and chassis ground. Expected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - Proceed to Test Step 5
Not OK - There is a short circuit in the harness or connectors.Repair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 3. CHECK THE RESISTANCE THROUGH THE MODBUS RS-485 SCADA DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Use a suitable piece of wire to short (Data Link +) and ( Data Link -) at the EMCP 4.
Measure the resistance between (Data Link +) and (Data Link -) at all other connectors in the circuit for the data link. Expected Result:The resistance is less than 10 Ohms.Results:
OK - The Data Link is OK. Proceed to test step 5
Not OK - There is an open circuit or excessive resistance in the harness or connectors.Repair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 4. CHECK FOR SHORTS IN THE CAN DATA LINK HARNESS
Disconnect all connectors from the suspected data link.
Measure the resistance between (data link +) and data link -). Expected Result:The resistance is approximately 60 Ohms.Results:
OK - Proceed to Test Step 5.
Not OK - If the resistance is approximately 120 ohms, a termination resistor is missing. If the resistance is much greater than 120 ohms, both termination resistors are missing or there is an open data link circuit. if the resistance is much less than 60 ohms, there is a short circuitRepair: Repair the wiring or replace the wiring.Proceed to Test Step 5Test Step 5. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the
Cat SIS web machinery list:
Parts spacer Caterpillar catalog:
1087638
SPACER
725, 730, 735, 735B, 740, 740B, 938F, 938G, AD55, AD55B, AD60, D250E, D250E II, D300D, D300E, D300E II, D350E II, D400E II, IT38F, IT38G, SE60 V XW
725, 730, 735, 735B, 740, 740B, 938F, 938G, AD55, AD55B, AD60, D250E, D250E II, D300D, D300E, D300E II, D350E II, D400E II, IT38F, IT38G, SE60 V XW
3V7729
SPACER
936F, 938F, 938G, 950F II, 960F, 966D, 966F II, 970F, 980C, 980F, 980F II, 980G, 980G II, 980H, AD30, AD45B, AD55, AD55B, AD60, AE40, IT38F
936F, 938F, 938G, 950F II, 960F, 966D, 966F II, 970F, 980C, 980F, 980F II, 980G, 980G II, 980H, AD30, AD45B, AD55, AD55B, AD60, AE40, IT38F
1V8443
SPACER
844, 844H, 844K, 854G, 854K, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K
844, 844H, 844K, 854G, 854K, 990, 990 II, 990H, 990K, 992C, 992D, 992G, 992K
8K0067
SPACER
834B, 834G, 834H, 836, 836G, 988B, 988F, 988F II, 988G, AD55, AD55B, AD60
834B, 834G, 834H, 836, 836G, 988B, 988F, 988F II, 988G, AD55, AD55B, AD60
9K0803
SPACER
834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 986H, 988B, 988F, 988F II, 988G, 988H, 988K, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, R2900, R2900G, R3000H
834B, 834G, 834H, 834K, 836, 836G, 836H, 836K, 986H, 988B, 988F, 988F II, 988G, 988H, 988K, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, R2900, R2900G, R3000H
8X9564
SPACER
24H, 24M, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F
24H, 24M, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F
7D2955
SPACER
770, 772, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 775B, 775D, 775E, 775F, 775G, 775G LRC, AD40, AD45, AD55, AD55B, AD60
770, 772, 773, 773B, 773D, 773E, 773F, 773G, 773G LRC, 775B, 775D, 775E, 775F, 775G, 775G LRC, AD40, AD45, AD55, AD55B, AD60
6I0977
SPACER
D10N, D10R, D9R
D10N, D10R, D9R
9W5556
SPACER
D11N, D11R, D11T
D11N, D11R, D11T
1311574
SPACER
D11N, D11R, D11T
D11N, D11R, D11T
3T7794
SPACER
D11N, D11R, D11T
D11N, D11R, D11T
3T7793
SPACER
D11N, D11R, D11T
D11N, D11R, D11T
2319230
SPACER
906, 906H, 907H, 908, 908H, C32, CX35-C18I, D6T LGP, D6T LGPPAT, D6T XL, M313D, M315D, M315D 2, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH, M330D
906, 906H, 907H, 908, 908H, C32, CX35-C18I, D6T LGP, D6T LGPPAT, D6T XL, M313D, M315D, M315D 2, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH, M330D
2844292
SPACER
C32
C32
3733375
SPACER
C32
C32
3733374
SPACER
C32
C32
2468834
SPACER
C32
C32
2914869
SPACER
C4.4
C4.4
2665355
SPACER
C4.4
C4.4
2656533
SPACER
C4.4, C6.6
C4.4, C6.6
1738073
SPACER
312D, 314E CR, 314E LCR, 315D L, 318C, 318D L, 319D, 319D L, 319D LN, 320C, 320C L, 320D, 320D FM, 320D L, 322C, 323D L, 325C, 374F L, 390F L, 950H, 953D, 962H, C7.1, C9, IT62H
312D, 314E CR, 314E LCR, 315D L, 318C, 318D L, 319D, 319D L, 319D LN, 320C, 320C L, 320D, 320D FM, 320D L, 322C, 323D L, 325C, 374F L, 390F L, 950H, 953D, 962H, C7.1, C9, IT62H
2302549
SPACER
3126B, C-9, C11, C13, C7, C9, CX31-C13I, CX31-C9I, SPP101, TH31-E61, TH35-C11I, TH35-C13I
3126B, C-9, C11, C13, C7, C9, CX31-C13I, CX31-C9I, SPP101, TH31-E61, TH35-C11I, TH35-C13I