If pump speed is not within TMI specifications, adjust height of screw (1) on swivel lever. Tightening the adjusting screw decreases speed droop and loosening increases speed droop.Note: Adjusting screw (1) can be loosened a maximum of 20 notches (clicks) or approximately five turns from a tightened position. Loosening the screw further may disengage the adjusting screw from the swivel lever, resulting in damage to the governor. Always tighten adjusting screw until at least one click is heard.
Illustration 62 g02807941
Remove the plug
Remove plug (2) .
Illustration 63 g02807956
Set speed by turning adjusting screw
Adjust speed. If Ng exceeds TMI specifications, tighten the adjusting screw. If Ng is less than the specified value, loosen the adjusting screw.
Illustration 64 g02807957
Adjust the maximum-speed stopper bolt
Adjust the maximum-speed stopper bolt until the speed at the start of high-speed control is Nf.
Check that the no-load maximum speed is Ng (described in Step 1). Continue adjustment until the specified value is obtained.
Illustration 65 g02807958
Increase pump speed to make sure that the control rack position reaches Ra.
Illustration 66 g02807959
Full-load Adjustment
Illustration 67 g02807997
Install the cover and adjust full-load stopper bolt
Install cover (3) on governor using bolts and lockwashers (2). Use caution when installing the cover to make sure that the O-ring seal is in the seal groove.
Illustration 68 g02807999
Position the control lever at maximum-speed position.
Adjust full-load stopper bolt (1) to the f"ull-load fuel injection quantity" position. See TMI for the specifications (Point A).
Install cap.Control Lever Angle Measurement
Illustration 69 g02808016
Measuring control lever angle at the "full-speed" and "idling" positions.
Measuring the control lever angle at the "idling" and "full" positions.
If the angle is not as specified by TMI, replace the shifters shim. If the control lever is positioned toward the "full" position, replace the shifters shim with a thicker one. When control lever is toward the "idling" position, replace the shim with a thinner one.Check Starting Delivery
Illustration 70 g02808018
Remove measurement adapter
Remove measurement adapter (1) .
Illustration 71 g02808038
Cap must be installed to check delivery rate
Install cap (2) .
Run pump at speed specified in TMI.
Check delivery rate with specifications listed in TMI.
Stop pump rotation.
Illustration 72 g02808058
Adjusting screw for setting fuel flow
If delivery rate does not meet TMI specifications, remove cap (2), loosen lock nut, and adjust screw (3). Adjusting screw outward decreases fuel flow and inward increases fuel flow.
Install cap (2) and recheck delivery rate. Repeat Steps 2 through 6 until delivery rate is at specified value.Lockwiring Caps of Adjustment Screws
All adjustment stops (screws) that directly affect engine performance should be lockwired after adjustment. Do not readjust any stop without using the test stand can adversely affect the engine and engine performance.
Parts spider Caterpillar catalog:
6B9752
SPIDER A.-FAN
Caterpillar
Caterpillar
6B9674
SPIDER A
Caterpillar
Caterpillar
6B7277
SPIDER A.-FAN
Caterpillar
Caterpillar
6B7136
SPIDER A.
Caterpillar
Caterpillar
6B6697
SPIDER A.
Caterpillar
Caterpillar
6B6696
SPIDER
Caterpillar
Caterpillar
6G3234
SPIDER
Caterpillar
Caterpillar
6F9310
SPIDER A.
Caterpillar
Caterpillar
6F7770
SPIDER A
Caterpillar
Caterpillar
6F1280
SPIDER A.
Caterpillar
Caterpillar
6F1279
SPIDER
Caterpillar
Caterpillar
6F0013
SPIDER & BRG.A
Caterpillar
Caterpillar