20R1695 SPINDLE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA20R1695
20R-1695
20R1695
CA20R1695
20R-1695
20R1695
Weight: 8232 pounds 3733 kg.
Information:
Illustration 1 g01065488
Schematic for Detent Coil (Lower)This diagnostic code is associated with the Detent Coil ( Lower). The FMI 05 means that the ECM has determined that an open in the circuit exists. The possible causes of this diagnostic code are listed:
The signal circuit from the ECM to the detent coil is open.
The return circuit from the detent coil is open.
The internal windings for the detent coil have high impedance.
The internal windings for the detent coil are open.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0360 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The machine response is listed:The lower detent coil cannot be energized resulting in loss of lower kickout feature.The control is unable to hold lever in detent position.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire H715-PU) to contact 2 (wire H716-WH).
Observe the status of the CID 0360 FMI 05.Expected Result:The CID 0360 FMI 05 remains active. The FMI has not changed and the "05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem. Stop.Test Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J2-37 (wire H715-PU) to contact J1-7 (wire H716-WH).Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire H715-PU or in wire H716-WH of the machine harness. Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0360 FMI 05.Expected Result:The CID 0360 FMI 05 is active. Results:
YES - The CID 0360 FMI 05 is active. The diagnostic code has not been corrected. The
Parts spindle Caterpillar catalog:
2059072
SPINDLE-FRONT
Caterpillar
Caterpillar
2059071
SPINDLE-FRONT
Caterpillar
Caterpillar
1U5999
SPINDLE
Caterpillar
Caterpillar
1U5997
SPINDLE-COLLET
Caterpillar
Caterpillar
1U5748
SPINDLE-OUTPUT
Caterpillar
Caterpillar
1R9714
SPINDLE
Caterpillar
Caterpillar
20R1707
SPINDLE AS
Caterpillar
Caterpillar
20R1706
SPINDLE AS.
Caterpillar
Caterpillar
20R1702
SPINDLE AS
Caterpillar
Caterpillar
20R1700
SPINDLE AS
Caterpillar
Caterpillar
20R1699
SPINDLE AS
Caterpillar
Caterpillar
20R1697
SPINDLE AS
Caterpillar
Caterpillar