Illustration 1 g01065561
Schematic of the Detent Coil (Tilt Back)This diagnostic code is associated with the Detent Coil (Tiltback). The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit. The possible causes of this diagnostic code are listed:
The internal windings for the detent coil have low impedance.
The internal windings for the detent coil are shorted.
The signal circuit from the ECM to the detent coil is shorted to ground.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0361 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The tiltback detent coil cannot be energized resulting in loss of tiltback kickout feature.The control is unable to hold lever in detent position.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 0361 FMI 06 changes to CID 0361 FMI 05 when the solenoid is disconnected.Results:
YES - CID 0361 FMI 06 changes to CID 0361 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Stop.
NO - CID 0361 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-13 (wire H720-BU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-13 (wire H720-BU) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0361 FMI 06. Expected Result:The CID 0361 FMI 06 is active. Results:
YES - The CID 0361 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is
Parts spindle Caterpillar catalog:
20R1700
SPINDLE AS
Caterpillar
Caterpillar
20R1699
SPINDLE AS
Caterpillar
Caterpillar
20R1697
SPINDLE AS
Caterpillar
Caterpillar
20R1695
SPINDLE AS
Caterpillar
Caterpillar
2059072
SPINDLE-FRONT
Caterpillar
Caterpillar
2059071
SPINDLE-FRONT
Caterpillar
Caterpillar
2234817
SPINDLE-CLASSI
Caterpillar
Caterpillar
2217602
SPINDLE
Caterpillar
Caterpillar
2202361
SPINDLE AS
Caterpillar
Caterpillar
20R2082
SPINDLE-REAR
Caterpillar
Caterpillar
20R1707
SPINDLE AS
Caterpillar
Caterpillar
20R1706
SPINDLE AS.
Caterpillar
Caterpillar