3100402 SPOOL AS Caterpillar parts
311F LRR, 312D, 312D L, 312E, 312E L, 314E CR, 314E LCR, 315D L, 316E L, 318E L
Rating:
Alternative (cross code) number:
CA3100402
310-0402
3100402
CA3100402
310-0402
3100402
Weight: 0.44 pounds 0 kg.
EXCAVATOR,
You can buy:
US$59.00
28 May 2025
FridayParts
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$51.55
08 Jun 2023
0.63[0.28] Pounds
CN: Notonparts Stor
Notonparts V-Ribbed Fan Belt 12PK2139 3100402 21189554 Compatible with Volvo Engine VN VNL ISX15
Notonparts Part Number: 12PK2139 3100402 21189554 || Compatible with Volvo Engine VN VNL ISX15 || Package Included: V-Ribbed Fan Belt x 1 || Strict Quality Standards And Superior Quality Parts. 100% Brand New And High Quality! || It Is a Replacement Part, Not Original Part. But It Can Work Good For You
Notonparts Part Number: 12PK2139 3100402 21189554 || Compatible with Volvo Engine VN VNL ISX15 || Package Included: V-Ribbed Fan Belt x 1 || Strict Quality Standards And Superior Quality Parts. 100% Brand New And High Quality! || It Is a Replacement Part, Not Original Part. But It Can Work Good For You
$52.55
06 Jun 2023
0.63[0.28] Pounds
CN: Notonparts Stor
Notonparts 12PK2139 21189554 3100402 V-Ribbed Fan Belt Compatible with Volvo Engine VNL ISX15 VN
Notonparts Part Number: 12PK2139 3100402 21189554 || Compatible with Volvo Engine VN VNL ISX15 || Item Weight: 0.63 Pound || Condition: High Quality, Well Packed || It Is a Replacement Part, Not Original Part. But It Can Work Good For You
Notonparts Part Number: 12PK2139 3100402 21189554 || Compatible with Volvo Engine VN VNL ISX15 || Item Weight: 0.63 Pound || Condition: High Quality, Well Packed || It Is a Replacement Part, Not Original Part. But It Can Work Good For You
$195.90
13 Jun 2022
3.1[1.40] Pounds
Amazon.com
3M Protecta 3100402 Self Retracting Lifeline Rebel 6' (18M) Web, Steel Rebar Hook (No Top Con), Black/Red
3M Compact and durable housing is designed to withstand the demands of challenging jobsites, it's built to last || Limits lifeline twisting for smoother operation and added worker satisfaction || Stops a falling worker within inches, providing more protection at low heights Designed for smooth consistent operation allowing the user to maintain normal work pace and not be interrupted with constant lock ups || Automatically locks and closes for added safety, and its 2-1/2" (625mm) large gate opening fits over larger anchorage structures || 6 ft (18 m) of 1" (25 cm) polyester web with steel rebar hook and swiveling anchorage || For industrial/occupational use only. Not for consumer sale or use
3M Compact and durable housing is designed to withstand the demands of challenging jobsites, it's built to last || Limits lifeline twisting for smoother operation and added worker satisfaction || Stops a falling worker within inches, providing more protection at low heights Designed for smooth consistent operation allowing the user to maintain normal work pace and not be interrupted with constant lock ups || Automatically locks and closes for added safety, and its 2-1/2" (625mm) large gate opening fits over larger anchorage structures || 6 ft (18 m) of 1" (25 cm) polyester web with steel rebar hook and swiveling anchorage || For industrial/occupational use only. Not for consumer sale or use
Compatible equipment models: 3100402:
Information:
General Installation Information
Caterpillar automatic transfer switches have been factory wired and tested. Installation requires mounting of the switch, connection of power source and load lines, connection of the automatic start/stop circuit, and connection of any options. Protect the transfer switch against excessive moisture, construction grit, metal chips or shavings at all times.Unpacking And Handling
1. Carefully unpack the transfer switch.2. Inspect for any damage that might have occurred during shipment. Never install a transfer switch that has been damaged or is defective in any way.3. Attach any lifting devices to enclosure mounting holes or channels only. Do not lift the switch at any other points. Protect the transfer switch against impact.Transfer Switch Mounting
Typical Example1. Typical switch mounting dimensions are shown in illustration above. For the actual dimensions see the subject "Transfer Switch Mounting Dimensions" in the Specifications section of this manual.2. Mount the switch enclosure vertically to a strong, rigid supporting structure.3. If necessary, level all mounting points by installing washers behind mounting holes (to prevent distortion).Power Source And Load Line Connections
Schematic Representation Of A Typical Transfer Switch Installation
Turn off both the normal and standby power supplies to the transfer switch before attempting to connect power source or load lines. Failure to turn off all power voltage supplies will result in extremely dangerous - possibly lethal - electrical shock.
Conductors - Conductors must be properly supported, protected by approved conduit, have approved insulation qualities, and be of the correct wire gauge size in accordance with applicable codes. All conductors should enter the switch enclosure adjacent to their respective terminal lugs. Transfer Mechanism Terminal Lugs - The transfer mechanism may be either a 3 or a 4-pole type. A neutral block may be provided for connection of 3-phase neutral lines. The neutral block is not required when the neutral line is to be switched on a 4-pole, 3-phase installation.1. Connect normal power source 3-phase lines to terminal lugs N1, N2 and N3.2. Connect standby power source 3-phase lines to terminals E1, E2 and E3.3. Connect load lines to terminals T1, T2 and T3. See illustration below. 4. Before connecting lines to the proper terminal lugs, remove surface oxides from the conductors with a wire brush. If aluminum wires are used, apply joint compound to the stripped end of the conductor. After tightening the terminal lug, wipe away excess joint compound.Tighten terminal lugs to 5.7 N m (50 lb in) for units rated 100 amperes; to 28.3 N m (250 lb in) for all other units.2-Wire Start Terminal Strip
Connect suitable, approved wiring to transfer switch terminals 178 and 183 and to the proper terminals in the standby generator set. Closure of this circuit by transfer switch circuit board action must result in automatic cranking and startup of the standby generator. Recommended wire gauge sizes for this wiring depends on the length of the wire and should be as recommended below: Standard Auxiliary Contacts
Auxiliary Switches - Right Side Of Transfer SwitchA standard transfer switch has two single-pole dual-throw (SPDT) switches which provide the
Caterpillar automatic transfer switches have been factory wired and tested. Installation requires mounting of the switch, connection of power source and load lines, connection of the automatic start/stop circuit, and connection of any options. Protect the transfer switch against excessive moisture, construction grit, metal chips or shavings at all times.Unpacking And Handling
1. Carefully unpack the transfer switch.2. Inspect for any damage that might have occurred during shipment. Never install a transfer switch that has been damaged or is defective in any way.3. Attach any lifting devices to enclosure mounting holes or channels only. Do not lift the switch at any other points. Protect the transfer switch against impact.Transfer Switch Mounting
Typical Example1. Typical switch mounting dimensions are shown in illustration above. For the actual dimensions see the subject "Transfer Switch Mounting Dimensions" in the Specifications section of this manual.2. Mount the switch enclosure vertically to a strong, rigid supporting structure.3. If necessary, level all mounting points by installing washers behind mounting holes (to prevent distortion).Power Source And Load Line Connections
Schematic Representation Of A Typical Transfer Switch Installation
Turn off both the normal and standby power supplies to the transfer switch before attempting to connect power source or load lines. Failure to turn off all power voltage supplies will result in extremely dangerous - possibly lethal - electrical shock.
Conductors - Conductors must be properly supported, protected by approved conduit, have approved insulation qualities, and be of the correct wire gauge size in accordance with applicable codes. All conductors should enter the switch enclosure adjacent to their respective terminal lugs. Transfer Mechanism Terminal Lugs - The transfer mechanism may be either a 3 or a 4-pole type. A neutral block may be provided for connection of 3-phase neutral lines. The neutral block is not required when the neutral line is to be switched on a 4-pole, 3-phase installation.1. Connect normal power source 3-phase lines to terminal lugs N1, N2 and N3.2. Connect standby power source 3-phase lines to terminals E1, E2 and E3.3. Connect load lines to terminals T1, T2 and T3. See illustration below. 4. Before connecting lines to the proper terminal lugs, remove surface oxides from the conductors with a wire brush. If aluminum wires are used, apply joint compound to the stripped end of the conductor. After tightening the terminal lug, wipe away excess joint compound.Tighten terminal lugs to 5.7 N m (50 lb in) for units rated 100 amperes; to 28.3 N m (250 lb in) for all other units.2-Wire Start Terminal Strip
Connect suitable, approved wiring to transfer switch terminals 178 and 183 and to the proper terminals in the standby generator set. Closure of this circuit by transfer switch circuit board action must result in automatic cranking and startup of the standby generator. Recommended wire gauge sizes for this wiring depends on the length of the wire and should be as recommended below: Standard Auxiliary Contacts
Auxiliary Switches - Right Side Of Transfer SwitchA standard transfer switch has two single-pole dual-throw (SPDT) switches which provide the
Cat SIS web machinery list:
Parts spool Caterpillar catalog:
1970220
SPOOL
311C, 312C, 312C L, 314C, 315C, 315D L, 318D L, 318D2 L
311C, 312C, 312C L, 314C, 315C, 315D L, 318D L, 318D2 L
2019271
SPOOL AS
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L
2291086
SPOOL
315C, 315D L, 316E L, 318D L, 318D2 L, 318E L
315C, 315D L, 316E L, 318D L, 318D2 L, 318E L
2597867
SPOOL
315C, 315D L, 318D L
315C, 315D L, 318D L
1970210
SPOOL
311C, 311F LRR, 312C, 312E, 312E L, 314C, 314E CR, 314E LCR, 316E L, 318E L, 325C
311C, 311F LRR, 312C, 312E, 312E L, 314C, 314E CR, 314E LCR, 316E L, 318E L, 325C
3376461
SPOOL
311D LRR, 311F LRR, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 314D CR, 314D LCR, 314E CR, 314E LCR
311D LRR, 311F LRR, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 314D CR, 314D LCR, 314E CR, 314E LCR
2671626
SPOOL AS
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN
2970686
SPOOL AS
311F LRR, 312D, 312D L, 312E, 312E L, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L
311F LRR, 312D, 312D L, 312E, 312E L, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L
3099960
SPOOL AS
315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN
315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN
2970687
SPOOL AS
311D LRR, 312D, 312D L, 312E, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318E L, 325D L
311D LRR, 312D, 312D L, 312E, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318E L, 325D L
3100406
SPOOL AS
311D LRR, 312D, 312D L, 314D CR, 314D LCR
311D LRR, 312D, 312D L, 314D CR, 314D LCR
2487869
SPOOL
314C, 314D CR, 314D LCR, 314E CR, 314E LCR
314C, 314D CR, 314D LCR, 314E CR, 314E LCR
3100406
SPOOL AS
311D LRR, 312D, 312D L, 314D CR, 314D LCR
311D LRR, 312D, 312D L, 314D CR, 314D LCR
3249573
SPOOL AS-VALVE
M313D, M315D 2
M313D, M315D 2
3249575
SPOOL AS-VALVE
M313D, M315D 2
M313D, M315D 2
3249574
SPOOL AS-VALVE
M313D, M315D 2
M313D, M315D 2
3232394
SPOOL
M313D
M313D
3232393
SPOOL
M313D
M313D
3746142
SPOOL AS
M316D
M316D
3661894
SPOOL
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH
2487869
SPOOL
314C, 314D CR, 314D LCR, 314E CR, 314E LCR
314C, 314D CR, 314D LCR, 314E CR, 314E LCR
2154876
SPOOL
314C, 314D CR, 314D LCR
314C, 314D CR, 314D LCR
2154874
SPOOL
314C, 314D CR, 314D LCR
314C, 314D CR, 314D LCR
2063348
SPOOL
314C, 314D CR, 314D LCR
314C, 314D CR, 314D LCR