8S3406 SPOOL-RATIO Caterpillar parts
518, 518C, 814, 920, 930, 941, 950, D4D
Rating:
Alternative (cross code) number:
CA8S3406
8S-3406
8S3406
CA8S3406
8S-3406
8S3406
Weight: 0.20 pounds 0 kg.
TRACK LOADER, WHEEL SKIDDER,
Compatible equipment models: 8S3406:
Information:
Procedure
1. Start the engine of the generator set prior to initiating the upgrade procedure. Verify that all systems are operational. Repair any faults that are logged prior to the conversion.2. Shut down the generator set. Record all set point information for reprogramming of the EMCP II+ Genset Control, including current hour meter reading. Disconnect the battery system by either turning OFF the battery disconnect switch or removing the ground wire from the negative terminal of the batteries.
Illustration 3. AC Transformer Box + (ATB+) (Front View): (a) H21. (b) H22. (c) H23. (27) T1-GEN T1/U. (28) T11-SLR1-A (L1). (29) T2-GEN T2/V. (30) T3-GEN T3/W. (31) T13-SLR2-A (L3). (32) TO-GEN-TO. (33) 50-TS1-50. (34) 51-TS1-51. (35) 52-TS1-52. (36) 53-TS1-53. (37) 80-VRTS-6. (38) 80-VAR-1. (39) 82-VRTS-7. (40) 82-VAR-2. (41) Pigtail and Deutsch plug with 8 wire harness: 1 P10-GSC-10 (VAN OUT),2 P11-GSC-11 (VBN OUT),3 P12-GSC-12 (VCN OUT),4 P4-GSC-4 (1A OUT),5 P5-GSC-5 (1B OUT),6 P6-GSC-6 (1C OUT),7 P16-GSC-16 (AC GROUND),8 NC. T11 and T13 connect to the synchronizing light resistors (SLR1, SLR2) of the optional synchronizing light module (SLM). For the Delta connected generators, DO NOT provide "TO" connection for the Delta generators.3. Disconnect all AC wiring and the 8-Pin Deutsch connector on the AC Transformer Box. Remove the ATB by removing the four locknuts securing the ATB to the EMCP II Sub Panel. A straight blade screwdriver, 7/16 inch socket, extension, and ratchet wrench are needed.Install the new ATB+ (13) into the same location. (Refer to Illustration 3.) Verify that all four locknuts are installed and tightened to 5.7 to 8.2 N m (50 to 73 lb in). Reconnect the AC wiring to the ATB+ (13) at the same points as on the original ATB. Install three fuses into the fuse block at the ATB+ (13). (If possible, use the fuses from the original ATB.)If an optional Synchronizing Light Module (SLM) (6) is installed in the Panel, remove the L1 wire (28) and L3 wire (31) connected to the TS1 in the generator terminal box and provide direct connection from TS1 to SS-4 and SS-6, respectively, on the SLM (6). If no SLM (6) is installed in the Panel, isolate and insulate the unused L1 wire (28) and L3 wire (31) for possible future use. If the generator wiring is a Wye configuration, a connection from the ATB+ (13) terminal strip location H21-H22-H23 (a-b-c) to the generator neutral (TO) must be made. The wire should be a minimum of 16 gauge. If the generator is wired in a Delta configuration, the additional wire should NOT be added. Ignore the ATB+ (13) chassis ground wire on Pin-8 Deutsch to Pin-17 GSC because it is not used on the EMCP II+. Remember to insulate and protect wires L1 (28) and L3 (31) because they are not used.4. Document and label the wiring scheme on the GSC Relay Module (10). Disconnect all wiring to the GSC Relay Module (10). Loosen and disconnect the 40-Pin connector plug. A 4 mm Hex wrench, straight blade screwdriver and
1. Start the engine of the generator set prior to initiating the upgrade procedure. Verify that all systems are operational. Repair any faults that are logged prior to the conversion.2. Shut down the generator set. Record all set point information for reprogramming of the EMCP II+ Genset Control, including current hour meter reading. Disconnect the battery system by either turning OFF the battery disconnect switch or removing the ground wire from the negative terminal of the batteries.
Illustration 3. AC Transformer Box + (ATB+) (Front View): (a) H21. (b) H22. (c) H23. (27) T1-GEN T1/U. (28) T11-SLR1-A (L1). (29) T2-GEN T2/V. (30) T3-GEN T3/W. (31) T13-SLR2-A (L3). (32) TO-GEN-TO. (33) 50-TS1-50. (34) 51-TS1-51. (35) 52-TS1-52. (36) 53-TS1-53. (37) 80-VRTS-6. (38) 80-VAR-1. (39) 82-VRTS-7. (40) 82-VAR-2. (41) Pigtail and Deutsch plug with 8 wire harness: 1 P10-GSC-10 (VAN OUT),2 P11-GSC-11 (VBN OUT),3 P12-GSC-12 (VCN OUT),4 P4-GSC-4 (1A OUT),5 P5-GSC-5 (1B OUT),6 P6-GSC-6 (1C OUT),7 P16-GSC-16 (AC GROUND),8 NC. T11 and T13 connect to the synchronizing light resistors (SLR1, SLR2) of the optional synchronizing light module (SLM). For the Delta connected generators, DO NOT provide "TO" connection for the Delta generators.3. Disconnect all AC wiring and the 8-Pin Deutsch connector on the AC Transformer Box. Remove the ATB by removing the four locknuts securing the ATB to the EMCP II Sub Panel. A straight blade screwdriver, 7/16 inch socket, extension, and ratchet wrench are needed.Install the new ATB+ (13) into the same location. (Refer to Illustration 3.) Verify that all four locknuts are installed and tightened to 5.7 to 8.2 N m (50 to 73 lb in). Reconnect the AC wiring to the ATB+ (13) at the same points as on the original ATB. Install three fuses into the fuse block at the ATB+ (13). (If possible, use the fuses from the original ATB.)If an optional Synchronizing Light Module (SLM) (6) is installed in the Panel, remove the L1 wire (28) and L3 wire (31) connected to the TS1 in the generator terminal box and provide direct connection from TS1 to SS-4 and SS-6, respectively, on the SLM (6). If no SLM (6) is installed in the Panel, isolate and insulate the unused L1 wire (28) and L3 wire (31) for possible future use. If the generator wiring is a Wye configuration, a connection from the ATB+ (13) terminal strip location H21-H22-H23 (a-b-c) to the generator neutral (TO) must be made. The wire should be a minimum of 16 gauge. If the generator is wired in a Delta configuration, the additional wire should NOT be added. Ignore the ATB+ (13) chassis ground wire on Pin-8 Deutsch to Pin-17 GSC because it is not used on the EMCP II+. Remember to insulate and protect wires L1 (28) and L3 (31) because they are not used.4. Document and label the wiring scheme on the GSC Relay Module (10). Disconnect all wiring to the GSC Relay Module (10). Loosen and disconnect the 40-Pin connector plug. A 4 mm Hex wrench, straight blade screwdriver and
Caterpillar parts catalog:
Parts spool Caterpillar catalog:
7S8496
SPOOL
518, 518C, 528, 528B, 530B, 920, 930
518, 518C, 528, 528B, 530B, 920, 930
7S8487
SPOOL
518, 518C, 528, 528B, 530B, 920, 930
518, 518C, 528, 528B, 530B, 920, 930
7S8488
SPOOL
518, 528, 920, 930
518, 528, 920, 930
9G9406
SPOOL
518, 518C, 528, 528B, 530B, 920
518, 518C, 528, 528B, 530B, 920
8S3388
SPOOL
814, 950, 966C
814, 950, 966C
2P9271
SPOOL
517, 518, 527, 769C, 773B, 777, D4HTSK II, D4HTSK III, D5HTSK II
517, 518, 527, 769C, 773B, 777, D4HTSK II, D4HTSK III, D5HTSK II
6T3206
SPOOL
518, D4HTSK II
518, D4HTSK II
6Y0750
SPOOL
518
518
9S8440
SPOOL ASSEM.
941, D4D
941, D4D
1P0561
SPOOL
120G, 12G, 130G, 140G, 14E, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 518, 518C, 528, 528B, 530B, 613, 613B, 814, 920, 930, 941, 950, 966C, D4D
120G, 12G, 130G, 140G, 14E, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 518, 518C, 528, 528B, 530B, 613, 613B, 814, 920, 930, 941, 950, 966C, D4D
9S9602
SPOOL
D8H
D8H
9M2047
SPOOL
D6C, D7G
D6C, D7G
1P4180
SPOOL ASSEM.
983, D8H
983, D8H
1P3594
SPOOL
583K, D8K, D9H
583K, D8K, D9H
7M5907
SPOOL
955H, 977H
955H, 977H
6S3165
SPOOL
D3
D3
5M9656
SPOOL
955H, 955K, 955L, D5, D5B
955H, 955K, 955L, D5, D5B
3S0061
SPOOL
955K, 955L
955K, 955L
3S0059
SPOOL
955K, 955L
955K, 955L
2P9177
SPOOL-SELECTOR
941, D4D
941, D4D