AVSPARE.COM
parts catalog

SPRING-COIL 0000036 - Caterpillar



0000036 SPRING-COIL Caterpillar parts SPRING
Rating:
46
Alternative (cross code) number:
CA0000036
000-0036
0000036
Caterpillar 0000036 SPRING-COIL
Weight: 0.98 pounds 0 kg.

Buy SPRING-COIL 0000036 Caterpillar genuine, new aftermarket tractor parts with delivery

You can buy parts: .

$5.99

12 May 2021

US: Nitrous Outlet
Nitrous Outlet .036 Jet
Nitrous Outlet
  For full view, you need register

Information:

Digital Sensor Inp #x Type Configuration
Illustration 1 g00663492
The digital sensor type configuration informs the system how to interpret the data from the attached sensor. To configure this value, highlight it and select "Change" at the lower left corner of the screen. You can also select the value by double-clicking the row. The current value will appear along with a pull-down menu to select the new value as shown in illustration 1. The choices are as follows:
Normally Closed - This type of sensor is normally at a closed (or ground) state and is open (or high) when active.
Normally Open - This type of sensor is normally at a open (or high) state and is closed (or ground) when active.
Not Configured - This is the default setting signifying that there is no sensor attached at this time.
Not Installed - This value is not currently allowed, but is included for possible future usage. If this is selected, the Product Link module will default the value to "Not Configured".Digital Sensor Input #x Description
Illustration 2 g00663490
This is a 24-character field used to describe what the sensor is monitoring. An example is "TRACK TENSION SENSOR". The text can be entered in lower or upper case, but will be displayed in upper case only. This value is used in the office software to display the sensor status. The default is "DIGITAL INPUT 1". To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 2.Digital Sensor Inp #x Delay Time
Illustration 3 g00663477
Each installed sensor uses this parameter to program the delay time before it goes active. This value can be between 0.1 to 1200 seconds. It is important to set this time correctly so spurious alarms are not set or activation is missed. The default value is 30.0 seconds. To configure this value, highlight it and select "Change" at the lower left corner of the screen. The new value may be entered as shown in illustration 3.


Parts spring Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.