1034867 SPRING Caterpillar parts
416B, 416C, 416D, 420D, 424D, 426B, 426C, 428B, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 446B, 446D
Rating:
Alternative (cross code) number:
CA1034867
103-4867
1034867
CA1034867
103-4867
1034867
Weight: 0.75 pounds 0 kg.
Information:
END CONFIGURATION
2
INITIAL TENSION
445
N
LENGTH
153
mm
OD
33
mm
SPRING RATE
33
BACKHOE LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Cornelius 1034867 GASKET MAGNETIC GA-230-B FOGEL (1034867)
Cornelius
Cornelius
Cornelius 1034867 GASKET MAGNETIC GA-230-B FOGEL (1034867)
Cornelius
Cornelius
Compatible equipment models: 1034867:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Periodically, use 300-8648 Insulation Testing Group to check the insulation resistance of the main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for A Periodic Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Isolate the stator windings of the generator by disconnecting all other leads and cables from the generator terminals. This includes connections to the voltage regulator, the control panel, the switchgear, or other devices.
Connect the insulation RED of the insulation tester lead to ground.
Connect the insulation BLACK lead of the tester to the wye point or star point of the generator windings.
For units that are 600 V or less, set the voltage to 500 V. For units that are more than 600 V, set the voltage to
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Periodically, use 300-8648 Insulation Testing Group to check the insulation resistance of the main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for A Periodic Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Isolate the stator windings of the generator by disconnecting all other leads and cables from the generator terminals. This includes connections to the voltage regulator, the control panel, the switchgear, or other devices.
Connect the insulation RED of the insulation tester lead to ground.
Connect the insulation BLACK lead of the tester to the wye point or star point of the generator windings.
For units that are 600 V or less, set the voltage to 500 V. For units that are more than 600 V, set the voltage to
Cat SIS web machinery list:
Parts spring Caterpillar catalog:
2S2596
SPRING
307B, 312B L, 312C, 315B L, 315C, 317B LN, 318B, 318C, 319C, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D...
307B, 312B L, 312C, 315B L, 315C, 317B LN, 318B, 318C, 319C, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D...
9T7750
SPRING
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
1418287
SPRING
120H ES, 120H NA, 135H NA, 30/30, 3114, 3116, 3126, 322 FM L, 446B, 446D, 45, 613C II, 924F, 928G, 938F, 938G, 950F, 950F II, 950G, 960F, 962G, 963B, AP-1000, AP-1050, BG-2455C, BG-245C, CB-634, CB-63...
120H ES, 120H NA, 135H NA, 30/30, 3114, 3116, 3126, 322 FM L, 446B, 446D, 45, 613C II, 924F, 928G, 938F, 938G, 950F, 950F II, 950G, 960F, 962G, 963B, AP-1000, AP-1050, BG-2455C, BG-245C, CB-634, CB-63...
2064127
SPRING-VALVE
3054, 3054B, 3056, 3056E, 312B L, 312C, 315B L, 416C, 416D, 420D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 550B, 554, 560B, 564, 574B, 908, 924G, 924GZ, 930G, AP-655C, AP-800C, BB-760, BG...
3054, 3054B, 3056, 3056E, 312B L, 312C, 315B L, 416C, 416D, 420D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 550B, 554, 560B, 564, 574B, 908, 924G, 924GZ, 930G, AP-655C, AP-800C, BB-760, BG...
1730126
SPRING
3054, 3054B, 312, 312B L, 312C, 315, 315B L, 317, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 554, 908, 914G, CB-434C, CB-534B, CB-534C, CB-535B, CP-433C, CP-433E, CS...
3054, 3054B, 312, 312B L, 312C, 315, 315B L, 317, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 554, 908, 914G, CB-434C, CB-534B, CB-534C, CB-535B, CP-433C, CP-433E, CS...
1210709
SPRING
416C, 426C, 428C, 436C, 438C
416C, 426C, 428C, 436C, 438C
1148861
SPRING AS-GAS
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
1594269
SPRING GP-GAS
414E, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 426C, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436C, 438C, 438D, 442D, 442E, 444E, 444F, 446D, 450E, 45...
414E, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 426C, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436C, 438C, 438D, 442D, 442E, 444E, 444F, 446D, 450E, 45...
1219748
SPRING AS
416C, 426C, 428C, 436C, 438C
416C, 426C, 428C, 436C, 438C
6E3265
SPRING
416C, 416D, 420D, 426C, 430D, 436C, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 784C, 785C, 785D, 834K...
416C, 416D, 420D, 426C, 430D, 436C, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 784C, 785C, 785D, 834K...
1641328
SPRING AS-GAS
414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 424D, 428D, 428E, 430D, 430E, 430F, 432D, 432E, 434E, 438D, 442D, 442E, 444E, 446D, 450E, 450F
414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 424D, 428D, 428E, 430D, 430E, 430F, 432D, 432E, 434E, 438D, 442D, 442E, 444E, 446D, 450E, 450F
3199512
SPRING AS-GAS
416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D, 446D, CB-434D, CB-534D, CB-564D, CW-34
416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D, 446D, CB-434D, CB-534D, CB-564D, CW-34
9R2486
SPRING
416, 416B, 416C, 416D, 420D, 424D, 426, 426B, 426C, 428, 428B, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 446, 446B, 446D
416, 416B, 416C, 416D, 420D, 424D, 426, 426B, 426C, 428, 428B, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 446, 446B, 446D
1167106
SPRING
3054, 416B, 428B, 436B, TH62, TH63, TH82
3054, 416B, 428B, 436B, TH62, TH63, TH82
1167095
SPRING
3054, 3056, 416B, 428B, TH62, TH63, TH82
3054, 3056, 416B, 428B, TH62, TH63, TH82
5D0998
SPRING-DISC
120, 120G, 12G, 130G, 140, 140G, 14E, 14G, 16, 160G, 16G, 215, 216, 225, 235, 236, 245, 416B, 416C, 426B, 426C, 428, 428B, 428C, 436C, 438C, 446, 446B, 793F, 793F CMD, 793F OEM, 795F AC, 797F, 824, 83...
120, 120G, 12G, 130G, 140, 140G, 14E, 14G, 16, 160G, 16G, 215, 216, 225, 235, 236, 245, 416B, 416C, 426B, 426C, 428, 428B, 428C, 436C, 438C, 446, 446B, 793F, 793F CMD, 793F OEM, 795F AC, 797F, 824, 83...
3C8727
SPRING
416B, 416C, 426B, 426C, 428B, 428C, 436C, 438C
416B, 416C, 426B, 426C, 428B, 428C, 436C, 438C
6I0786
SPRING
3054, 307, 416B, 416C, 426B, 426C, 428B, 428C, 436C, 438C, 554, AP-800C, BG-225B, BG-225C, CB-434B, CB-434C, CB-534B, CB-534C, CB-535B, CB-544, CB-545, CP-433C, CP-433E, CS-431C, M312, M315, PF-290B, ...
3054, 307, 416B, 416C, 426B, 426C, 428B, 428C, 436C, 438C, 554, AP-800C, BG-225B, BG-225C, CB-434B, CB-434C, CB-534B, CB-534C, CB-535B, CB-544, CB-545, CP-433C, CP-433E, CS-431C, M312, M315, PF-290B, ...
6Y2038
SPRING-GUIDE
416, 416B, 426B, 428, 428B, 436
416, 416B, 426B, 428, 428B, 436
6Y1341
SPRING
414E, 416, 416B, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424B, 424B HD, 424D, 426, 426B, 426C, 428, 428B, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436, 436...
414E, 416, 416B, 416C, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424B, 424B HD, 424D, 426, 426B, 426C, 428, 428B, 428C, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 436, 436...
7T3122
SPRING AS
416, 416B, 426, 426B, 428, 428B, 436, RT50
416, 416B, 426, 426B, 428, 428B, 436, RT50
8E9322
SPRING
416B, 426, 426B, 428, 428B
416B, 426, 426B, 428, 428B
7T2674
SPRING
416, 416B, 426, 426B, 428, 436, RT50
416, 416B, 426, 426B, 428, 436, RT50
7T3129
SPRING
416, 416B, 426, 426B, 428, 428B, 436, RT50
416, 416B, 426, 426B, 428, 428B, 436, RT50