Information:
Illustration 1 g02164545
Schematic of the Counterbalance Standby SolenoidThe Counterbalance Standby Solenoid is located behind the LH Machine side panel. The solenoid is part of the bank of nine solenoids.
Illustration 2 g02211494
Machine LH Side Panel Open
Illustration 3 g02211358
Solenoid Bank behind LH side panel
Illustration 4 g02219353
View from below of the Solenoid bank (1) Park Brake Solenoid (Wire 374-PK) (2) Counterbalance Lock Solenoid (Wire X771-YL) (3) Auger Raise Solenoid (Wire 787-WH) (4) Screed Float Solenoid (Wire A905-GN) (5) Screed Raise Solenoid (Wire F742-PU) (6) Counterbalance Solenoid (Wire T841-PK) (7) Counterbalance Standby Solenoid (Wire T840-PU) (8) Auger Lower Solenoid (Wire 781-PK) (9) Propel Mode (Gear) Shift Solenoid (Wire 334-BU)This diagnostic code is associated with the Counterbalance Standby Solenoid (7). The FMI 06 code means that the LH Operator ECM has detected that the current for the solenoid circuit is above normal. Note: The LH Operator ECM is located under the LH Operator Platform.The conditions which cause the activation of this diagnostic code include the following:
The energize circuit of the solenoid is shorted to a ground source.
The solenoid has failed.
The ECM has failed. This situation is unlikely. System Response:When this diagnostic code is active, the following occurs:
Counterbalance system is disabled.
Operator station fault lamp is active.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the circuit are clean, that the connections are secure, and that the connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the machine harness at the solenoid. Expected Result:The active CID 2591 FMI 06 diagnostic code changes to a CID 2591 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 2591 FMI 06 diagnostic code changes to a CID 2591 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F). Replace the solenoid.STOP
NO - The CID 2591 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUNDThe solenoid remains disconnected from the machine
Caterpillar parts catalog:
Parts spring Caterpillar catalog:
4185961
SPRING GP-GAS
Caterpillar
Caterpillar
3952950
SPRING
Caterpillar
Caterpillar
5489005
SPRING
Caterpillar
Caterpillar
5217892
SPRING AS
Caterpillar
Caterpillar
4937529
SPRING
Caterpillar
Caterpillar
4932622
SPRING
Caterpillar
Caterpillar
4528031
SPRING AS-GAS
Caterpillar
Caterpillar
4523704
SPRING AS-GAS
Caterpillar
Caterpillar
4446016
SPRING AS-GAS
Caterpillar
Caterpillar
4429962
SPRING-RETAINER
Caterpillar
Caterpillar
4429960
SPRING-RETURN
Caterpillar
Caterpillar
4386971
SPRING AS-GAS
Caterpillar
Caterpillar