4446016 SPRING AS-GAS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4446016
444-6016
4446016
CA4446016
444-6016
4446016
Weight: 0.48 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Illustration 1 g02238794
Schematic of the Counterbalance Lock SolenoidThe Counterbalance Lock Solenoid is located behind the LH Machine side panel. The solenoid is part of the bank of nine solenoids.
Illustration 2 g02211494
Machine LH Side Panel Open
Illustration 3 g02211358
Solenoid Bank behind LH side panel
Illustration 4 g02219353
View from below of the Solenoid bank (1) Park Brake Solenoid (Wire 374-PK) (2) Counterbalance Lock Solenoid (Wire X771-YL) (3) Auger Raise Solenoid (Wire 787-WH) (4) Screed Float Solenoid (Wire A905-GN) (5) Screed Raise Solenoid (Wire F742-PU) (6) Counterbalance Solenoid (Wire T841-PK) (7) Counterbalance Standby Solenoid (Wire T840-PU) (8) Auger Lower Solenoid (Wire 781-PK) (9) Propel Mode (Gear) Shift Solenoid (Wire 334-BU)This diagnostic code is associated with the Counterbalance Lock Solenoid (2). The FMI 03 means that the LH Operator ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Note: The LH Operator ECM is located under the LH Operator Platform.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This situation is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. System Response:When this diagnostic code is active, the following occurs:
Screed raise lock is active until fault is fixed. Screed will not raise.
Operator station fault lamp is active.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the disconnect switch and the key start switch to
Caterpillar parts catalog:
Parts spring Caterpillar catalog:
4429962
SPRING-RETAINER
Caterpillar
Caterpillar
4429960
SPRING-RETURN
Caterpillar
Caterpillar
4386971
SPRING AS-GAS
Caterpillar
Caterpillar
4209810
SPRING-RECOIL
Caterpillar
Caterpillar
4185961
SPRING GP-GAS
Caterpillar
Caterpillar
3952950
SPRING
Caterpillar
Caterpillar
4769049
SPRING AS-GAS
Caterpillar
Caterpillar
4741925
SPRING AS-GAS
Caterpillar
Caterpillar
4645080
SPRING
Caterpillar
Caterpillar
4547672
SPRING
Caterpillar
Caterpillar
4528031
SPRING AS-GAS
Caterpillar
Caterpillar
4523704
SPRING AS-GAS
Caterpillar
Caterpillar