4M5923 SPRING Caterpillar parts
594, 955H, 977H, 983, D10, D348, D349, D7F, D8H, D8K
Rating:
Alternative (cross code) number:
CA4M5923
4M-5923
4M5923
CA4M5923
4M-5923
4M5923
Weight: 0.13 pounds 0 kg.
Information:
ACTUAL RATE
6.15
N/MM
FREE LENGTH
111.252
mm
OD
20.574
mm
SOLID LENGTH
61.976
mm
WIRE DIAMETER
2.87
mm
INDUSTRIAL ENGINE, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$7.03
28 Apr 2022
Amazon.com
CTP 4M5923 Spring for Heavy Equipment
CTP Spring Only || Sold in each || Easy in-and-out fit
CTP Spring Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 4M5923:
Information:
System Operation Description:Use this procedure to troubleshoot the data link if a problem is suspected with the data link or if one of the diagnostic codes in Table 1 is active or easily repeated.
Table 1
Diagnostic Codes Table
CDL Code and Description Conditions which Generate this Code System Response
247-9
SAE J1939 Data Link:Abnormal Update Rate The SCR system ECM has lost communication with the engine ECM on the global CAN data link. The code is logged.
2348-9
SAE J1939 Data Link #2:Abnormal Update Rate The SCR system ECM has lost all communication on the local CAN data link The code is logged.
3002-6
Engine Exhaust NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3002-9
Engine Exhaust NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged.
3609-6
Aftertreatment #1 Outlet #1 NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3609-9
Aftertreatment #1 Outlet #1 NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged.
3610-6
Aftertreatment #1 Outlet #2 NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3610-9
Aftertreatment #1 Outlet #2 NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged. This procedure verifies the integrity of the global CAN data link between the SCR system ECM and the engine ECM.This procedure verifies the integrity of the local CAN data link between the SCR system ECM and the following components:
Intake #1 NOx Sensor
Outlet #1 NOx Sensor
Outlet #2 NOx SensorIf Caterpillar Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the engine ECM and to the service tool connector.The data links provide a communication link between the various control modules on the application.Cat ET may display the following error message:"The version of the ECM is not recognized and the integrity of the changed parameters and displayed data is not guaranteed."If this message is displayed, the flash file in the ECM may be newer than the version of Cat ET, or the latest version of Cat ET has not been installed. You must correct this condition prior to continuing with this procedure.Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the main disconnect switch to the OFF position.
Thoroughly inspect the ECM connector J1/P1 and J2/P2. Inspect all of the connectors to other modules on the data links. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 1 g02721158
P2 ECM connector
(P2-11) CAN data link −
(P2-12) CAN data
Table 1
Diagnostic Codes Table
CDL Code and Description Conditions which Generate this Code System Response
247-9
SAE J1939 Data Link:Abnormal Update Rate The SCR system ECM has lost communication with the engine ECM on the global CAN data link. The code is logged.
2348-9
SAE J1939 Data Link #2:Abnormal Update Rate The SCR system ECM has lost all communication on the local CAN data link The code is logged.
3002-6
Engine Exhaust NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3002-9
Engine Exhaust NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged.
3609-6
Aftertreatment #1 Outlet #1 NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3609-9
Aftertreatment #1 Outlet #1 NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged.
3610-6
Aftertreatment #1 Outlet #2 NOx Level Sensor:Current Above Normal The ECM detects a short in the power supply circuit for the sensor.
Troubleshoot this code before the 3216-9 The code is logged.
3610-9
Aftertreatment #1 Outlet #2 NOx Level Sensor:Abnormal Update Rate The SCR system ECM has lost communication with the sensor on the local CAN data link The code is logged. This procedure verifies the integrity of the global CAN data link between the SCR system ECM and the engine ECM.This procedure verifies the integrity of the local CAN data link between the SCR system ECM and the following components:
Intake #1 NOx Sensor
Outlet #1 NOx Sensor
Outlet #2 NOx SensorIf Caterpillar Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the engine ECM and to the service tool connector.The data links provide a communication link between the various control modules on the application.Cat ET may display the following error message:"The version of the ECM is not recognized and the integrity of the changed parameters and displayed data is not guaranteed."If this message is displayed, the flash file in the ECM may be newer than the version of Cat ET, or the latest version of Cat ET has not been installed. You must correct this condition prior to continuing with this procedure.Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the main disconnect switch to the OFF position.
Thoroughly inspect the ECM connector J1/P1 and J2/P2. Inspect all of the connectors to other modules on the data links. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 1 g02721158
P2 ECM connector
(P2-11) CAN data link −
(P2-12) CAN data
Cat SIS web machinery list:
Parts spring Caterpillar catalog:
2P9666
SPRING
583K, D8H, D8K
583K, D8H, D8K
5M2058
SPRING
572G, 983B, D7F, D7G
572G, 983B, D7F, D7G
9H5536
SPRING
14E, 572G, D7F, D7G, D7G2, D8H
14E, 572G, D7F, D7G, D7G2, D8H
1M4593
SPRING
583H, 583K, D8H, D8K
583H, 583K, D8H, D8K
1A8096
SPRING-VALVE
120B, 12E, 12F, 12G, 140B, 140G, 14E, 16, 16G, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 826C, 834B, 836, 931B, 936, 950, 950F, 950F II, 950G, 950G II, 950H, 950K, 955H, 960F, 962G, 962G II, ...
120B, 12E, 12F, 12G, 140B, 140G, 14E, 16, 16G, 814F, 814F II, 815B, 815F, 815F II, 816F, 816F II, 826C, 834B, 836, 931B, 936, 950, 950F, 950F II, 950G, 950G II, 950H, 950K, 955H, 960F, 962G, 962G II, ...
1J9533
SPRING
163, 183, 623, 631C, 633C, 633D, 637D, 639D, 641, 641B, 651, 657, 814, 824B, 824C, 834, 834B, 950, 966C, 966D, 966F, 966F II, 970F, 977H, 980B, 980C, 980F, 988, 988B, 988F, 988F II, 992, 992C, 992D, A...
163, 183, 623, 631C, 633C, 633D, 637D, 639D, 641, 641B, 651, 657, 814, 824B, 824C, 834, 834B, 950, 966C, 966D, 966F, 966F II, 970F, 977H, 980B, 980C, 980F, 988, 988B, 988F, 988F II, 992, 992C, 992D, A...
5H8673
SPRING
583H, D8H
583H, D8H
8H6507
SPRING ASSEM.
583H, D8H
583H, D8H
2B2254
SPRING
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 633C, 633D, 955C, 955H
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 633C, 633D, 955C, 955H
3J0712
SPRING
163, 955H, 977D
163, 955H, 977D
5H9474
SPRING
977D, 977H
977D, 977H
7M2923
SPRING (OUTER)
621, 631C, 651, 657, 824B, 834, 977H, 988
621, 631C, 651, 657, 824B, 834, 977H, 988
7B4970
SPRING
D348, D349
D348, D349
2J4045
SPRING
12F, 140, 141, 14E, 153, 16, 163, 172, 191, 225, 572G, 583H, 594H, 631C, 641, 641B, 816, 941, 943, 951B, 963, D348, D349, D379, D379B, D398, D398A, D399
12F, 140, 141, 14E, 153, 16, 163, 172, 191, 225, 572G, 583H, 594H, 631C, 641, 641B, 816, 941, 943, 951B, 963, D348, D349, D379, D379B, D398, D398A, D399
2F6689
SPRING
D342, D342C, D348, D353C, D379B, D399, G399
D342, D342C, D348, D353C, D379B, D399, G399
3N3366
SPRING ASSEM.
D342, D342C, D348, D353C, D399
D342, D342C, D348, D353C, D399
2F6761
SPRING
3512, 3516, D342, D342C, D348, D353C, D399
3512, 3516, D342, D342C, D348, D353C, D399
6L5417
SPRING
D342, D342C, D348, D349, D353C, D379B, G399
D342, D342C, D348, D349, D353C, D379B, G399
4B4899
SPRING
3406, 824C, 826C, 938F, 966D, 977L, 980C, 983B, D343, D353C, IT38F
3406, 824C, 826C, 938F, 966D, 977L, 980C, 983B, D343, D353C, IT38F
8L8951
SPRING
D379, D379B
D379, D379B
1N8291
SPRING AND FORK ASSEM.
3304, 3306, D320A, G342C
3304, 3306, D320A, G342C
6L3991
SPRING
3304, 3306, 3406, D320A, D343, G342C
3304, 3306, 3406, D320A, D343, G342C
7H3856
SPRING
D320A, D330A, D333A
D320A, D330A, D333A
3N4316
SPRING
3512, D346, D348, D349, D379A, D379B, D399
3512, D346, D348, D349, D379A, D379B, D399