7M5865 SPRING Caterpillar parts
16, 215, 245, 611, 615, 615C, 621, 657, 666, 769, 772, 777, 824, 834, 988, D250B, D25C, D300B, R1700 II
Rating:
Alternative (cross code) number:
CA7M5865
7M-5865
7M5865
CA7M5865
7M-5865
7M5865
Weight: 0.05 pounds 0 kg.
Information:
ACTUAL RATE
5.533
N/MM
FREE LENGTH
77.724
mm
OD
15.138
mm
SOLID LENGTH
44.704
mm
WIRE DIAMETER
2.184
mm
ARTICULATED TRUCK, WHEEL TRACTOR,
Compatible equipment models: 7M5865:
Information:
Refer to SEBU6617, the 3304B Generator Set Engine Operation and Maintenance Manual, for basic engine start/stop/operation procedures.Perform these checks before operating the engine and generator.
Typical fuel gauge, located in the base inside of the enclosure.* Check the fuel level. The fuel tank capacity of the XQ125 Rental Generator Set is 530.6 L (140 US gal). The full load maximum fuel consumption for the XQ125 Rental Generator Set is approximately 38 L/hour (10 US gal/hour). Refer to SEBU6617, the 3304B Operation and Maintenance Manual, for the proper lubrication oil and coolant.
Coolant filler cap (1), oil filler cap (2), and oil level gauge (dipstick) (3). * Check the oil level with the engine stopped. The oil level should be between the ADD and FULL marks on the ENGINE STOPPED side of the dipstick. If necessary, remove the oil filler cap and add oil. Ensure that the oil level is not above the FULL mark. Clean the oil filler cap. Clean the cap receptacle. Install the cap.* Check the coolant level with the engine stopped and cool. Remove the coolant filler cap slowly to relieve any pressure. Maintain the coolant level within 13 mm (1/2 inch) below the bottom of the fill pipe. Clean the coolant filler cap. Inspect the cap. Replace the cap if the gaskets are damaged. Clean the coolant filler cap receptacle. Install the cap.Load Connection Procedure
Distribution Panels
Dual voltage distribution panel (1), single voltage distribution panel (2).The dual voltage distribution panel (240V and 480V) is equipped with HIGH and LOW voltage main circuit breakers. This panel is equipped with HIGH and LOW voltage main load connections. The main load connections do not require changeover or switching.The single voltage distribution panel (600V) is equipped with a single voltage main circuit breaker and a single voltage main load connection.
Contact with loose connectors can result in electrical shock and may cause injury or death.
Verify the correct load phase rotation with the generator prior to connecting the output power cables.
The load connection procedure is illustrated with a dual voltage distribution panel. All of the instructions are typical for both the dual voltage distribution panel and the single voltage distribution panel.
Circuit breakers (1), receptacles (2), buss bars (3), reinforcement bar (4), remote start/stop connection points (5), ground connection (6).1. Ensure that the generator set is not operating. Place main circuit breaker(s) (1) in the OFF (open) position.For dual voltage distribution panels, determine HIGH (480V) or LOW (240V) voltage use. Select the applicable receptacles (2), or buss bars (3).2. Connect the output power cables to receptacles (2) or to buss bars (3).If it is necessary to connect the output power cables to the buss bars:2a. A clear plastic shield covers the buss bars. Remove the clear plastic shield. Removing the shield activates the shutoff switch. Remove reinforcement bar (4).2b. Connect the output power cables to buss bars (3).2c. Install reinforcement bar (4). Install the clear plastic shield. The unit will not operate unless the shield is properly installed. Torque all of the bolts
Typical fuel gauge, located in the base inside of the enclosure.* Check the fuel level. The fuel tank capacity of the XQ125 Rental Generator Set is 530.6 L (140 US gal). The full load maximum fuel consumption for the XQ125 Rental Generator Set is approximately 38 L/hour (10 US gal/hour). Refer to SEBU6617, the 3304B Operation and Maintenance Manual, for the proper lubrication oil and coolant.
Coolant filler cap (1), oil filler cap (2), and oil level gauge (dipstick) (3). * Check the oil level with the engine stopped. The oil level should be between the ADD and FULL marks on the ENGINE STOPPED side of the dipstick. If necessary, remove the oil filler cap and add oil. Ensure that the oil level is not above the FULL mark. Clean the oil filler cap. Clean the cap receptacle. Install the cap.* Check the coolant level with the engine stopped and cool. Remove the coolant filler cap slowly to relieve any pressure. Maintain the coolant level within 13 mm (1/2 inch) below the bottom of the fill pipe. Clean the coolant filler cap. Inspect the cap. Replace the cap if the gaskets are damaged. Clean the coolant filler cap receptacle. Install the cap.Load Connection Procedure
Distribution Panels
Dual voltage distribution panel (1), single voltage distribution panel (2).The dual voltage distribution panel (240V and 480V) is equipped with HIGH and LOW voltage main circuit breakers. This panel is equipped with HIGH and LOW voltage main load connections. The main load connections do not require changeover or switching.The single voltage distribution panel (600V) is equipped with a single voltage main circuit breaker and a single voltage main load connection.
Contact with loose connectors can result in electrical shock and may cause injury or death.
Verify the correct load phase rotation with the generator prior to connecting the output power cables.
The load connection procedure is illustrated with a dual voltage distribution panel. All of the instructions are typical for both the dual voltage distribution panel and the single voltage distribution panel.
Circuit breakers (1), receptacles (2), buss bars (3), reinforcement bar (4), remote start/stop connection points (5), ground connection (6).1. Ensure that the generator set is not operating. Place main circuit breaker(s) (1) in the OFF (open) position.For dual voltage distribution panels, determine HIGH (480V) or LOW (240V) voltage use. Select the applicable receptacles (2), or buss bars (3).2. Connect the output power cables to receptacles (2) or to buss bars (3).If it is necessary to connect the output power cables to the buss bars:2a. A clear plastic shield covers the buss bars. Remove the clear plastic shield. Removing the shield activates the shutoff switch. Remove reinforcement bar (4).2b. Connect the output power cables to buss bars (3).2c. Install reinforcement bar (4). Install the clear plastic shield. The unit will not operate unless the shield is properly installed. Torque all of the bolts
Cat SIS web machinery list:
Parts spring Caterpillar catalog:
8J4479
SPRING
225, 245, D6H
225, 245, D6H
6P1837
SPRING
235
235
6N3547
SPRING
621B
621B
4J5731
SPRING
129, 245, 245B
129, 245, 245B
8J0438
SPRING
231D, 235, 235D, 245, 920, 943, 953, 953B, 955L, 963, 963B, 973, 977L, 983B
231D, 235, 235D, 245, 920, 943, 953, 953B, 955L, 963, 963B, 973, 977L, 983B
4J4790
SPRING
12F, 140B, 14E, 173B, 183B, 225, 769, 931B, 988, D10, D11N, D11R, D11T, D6C, D7G, D8K, D9H
12F, 140B, 14E, 173B, 183B, 225, 769, 931B, 988, D10, D11N, D11R, D11T, D6C, D7G, D8K, D9H
2J6246
SPRING
235, 235C, 245, 245B
235, 235C, 245, 245B
8J6241
SPRING
235, 245
235, 245
3G0752
SPRING
215, 225
215, 225
8J1630
SPRING
120G, 12G, 130G, 140G, 14G, 160G, 16G, 215, 225, 245
120G, 12G, 130G, 140G, 14G, 160G, 16G, 215, 225, 245