8H9181 SPRING-BUMPER Caterpillar parts
120, 16, 1673, 1673B, 1673C, 1674, 1676, 1693, 16G, 215, 245, 3304, 3306, 3406, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 561C, 589, 621, 621B, 621R, 623, 627, 631C, 631E, 633C, 637D, 637E, 641B, 650B, ...
Rating:
Alternative (cross code) number:
CA8H9181
8H-9181
8H9181
CA8H9181
8H-9181
8H9181
Weight: 0.01 pounds 0 kg.
Information:
HEIGHT
1.092
mm
ID/THREAD SIZE
7.925
LOAD WHEN FLAT
0
N
OD
19.05
mm
THICKNESS
.711
mm
COLD PLANER, WHEEL TRACTOR,
Compatible equipment models: 8H9181:
Information:
System Operation Description:The engine does not shut down when a shutdown fault occurs.
Illustration 1 g00445004
Fuel Control Relay For ETR Systems
Illustration 2 g00445005
System Schematic For Air Shutoff Relay (ASR)Note: It is extremely important that GSC+ setpoint P023 is correct for the engine application. Make certain setpoint P023 is programmed correctly for the engine application before continuing with this procedure. Note: It is extremely important that GSC+ setpoint P001 is correct for the engine. All generator sets packaged in Larne, Ireland covered by this manual must ALWAYS have this setpoint programmed to 0 (ETR fuel solenoid) for both fuel solenoid types (ETR or ETS). There are several possible causes why an engine is not shutting down when a shutdown fault occurs.
Operator Error: The operating conditions of the generator may not be understood by the operator. Ensure that the condition is one that should cause an engine shutdown.
Programming Error - Fault Is Overridden Or Disabled: It is possible to program the GSC+ in order to override certain shutdown faults. An overridden shutdown fault will be treated as an alarm fault. The YELLOW fault alarm indicator will be FLASHING instead of the RED fault shutdown indicator. If the GSC+ is programmed in order to disable a particular fault, there will not be any fault indicators or codes shown on the GSC+. In these cases, it is a good idea to check any setpoints related to that fault. For example, if a generator is not shutting down when an overvoltage fault occurs, make sure setpoint P104(Overvoltage shutdown enable) is programmed correctly.
Programming Error - Setpoints Incorrect For Application Or Customer Needs: It is possible to program the GSC+ setpoints to a value that does not allow the situation to be recognized by the GSC+ as a shutdown condition. In this case, check the appropriate setpoints for correct values. For example, if the generator is not shutting down when a high coolant temperature condition occurs, make sure setpoint P015 (High Water Temperature Shutdown) is correct for the application.
Faulty Component: Some examples of faulty components that could prevent the GSC+ from shutting down the engine are: GSC+ and a broken or shorted harness wire.. In this case, the GSC+ will be issuing a command to shut down the engine due to a diagnostic code, but the engine remains running. Test Step 1. CHECK FOR DIAGNOSTIC CODES
Check the GSC+ for a diagnostic code on the upper display.Expected Result:The GSC+ should show a diagnostic code on the upper display.Results:
YES - The GSC+ shows a diagnostic code on the upper display.Repair: See theTesting and Adjusting section of this book for the diagnostic code that is displayed on the GSC+. Stop.
NO - The GSC+ does NOT show a diagnostic code on the upper display. Proceed to Test Step 2.Test Step 2. CHECK THE YELLOW FAULT ALARM INDICATOR
Check the display area of the GSC+ for the yellow fault alarm indicator.Expected Result:The yellow fault alarm indicator should be illuminated CONTINUOUSLY.Results:
YES - The yellow fault alarm indicator is illuminated CONTINUOUSLY.Repair: The GSC+ has
Illustration 1 g00445004
Fuel Control Relay For ETR Systems
Illustration 2 g00445005
System Schematic For Air Shutoff Relay (ASR)Note: It is extremely important that GSC+ setpoint P023 is correct for the engine application. Make certain setpoint P023 is programmed correctly for the engine application before continuing with this procedure. Note: It is extremely important that GSC+ setpoint P001 is correct for the engine. All generator sets packaged in Larne, Ireland covered by this manual must ALWAYS have this setpoint programmed to 0 (ETR fuel solenoid) for both fuel solenoid types (ETR or ETS). There are several possible causes why an engine is not shutting down when a shutdown fault occurs.
Operator Error: The operating conditions of the generator may not be understood by the operator. Ensure that the condition is one that should cause an engine shutdown.
Programming Error - Fault Is Overridden Or Disabled: It is possible to program the GSC+ in order to override certain shutdown faults. An overridden shutdown fault will be treated as an alarm fault. The YELLOW fault alarm indicator will be FLASHING instead of the RED fault shutdown indicator. If the GSC+ is programmed in order to disable a particular fault, there will not be any fault indicators or codes shown on the GSC+. In these cases, it is a good idea to check any setpoints related to that fault. For example, if a generator is not shutting down when an overvoltage fault occurs, make sure setpoint P104(Overvoltage shutdown enable) is programmed correctly.
Programming Error - Setpoints Incorrect For Application Or Customer Needs: It is possible to program the GSC+ setpoints to a value that does not allow the situation to be recognized by the GSC+ as a shutdown condition. In this case, check the appropriate setpoints for correct values. For example, if the generator is not shutting down when a high coolant temperature condition occurs, make sure setpoint P015 (High Water Temperature Shutdown) is correct for the application.
Faulty Component: Some examples of faulty components that could prevent the GSC+ from shutting down the engine are: GSC+ and a broken or shorted harness wire.. In this case, the GSC+ will be issuing a command to shut down the engine due to a diagnostic code, but the engine remains running. Test Step 1. CHECK FOR DIAGNOSTIC CODES
Check the GSC+ for a diagnostic code on the upper display.Expected Result:The GSC+ should show a diagnostic code on the upper display.Results:
YES - The GSC+ shows a diagnostic code on the upper display.Repair: See theTesting and Adjusting section of this book for the diagnostic code that is displayed on the GSC+. Stop.
NO - The GSC+ does NOT show a diagnostic code on the upper display. Proceed to Test Step 2.Test Step 2. CHECK THE YELLOW FAULT ALARM INDICATOR
Check the display area of the GSC+ for the yellow fault alarm indicator.Expected Result:The yellow fault alarm indicator should be illuminated CONTINUOUSLY.Results:
YES - The yellow fault alarm indicator is illuminated CONTINUOUSLY.Repair: The GSC+ has
Cat SIS web machinery list:
Parts spring Caterpillar catalog:
7S2128
SPRING
824B, 826B, 834, 988, 992
824B, 826B, 834, 988, 992
5K2334
SPRING
950
950
4K3635
SPRING
950
950
2P5700
SPRING
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 772B, 773B, 776, 784B, 785, 785B, 789B, 793B
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 772B, 773B, 776, 784B, 785, 785B, 789B, 793B
1S8478
SPRING
120G, 12G, 130G, 140G, 160G, 769, 772
120G, 12G, 130G, 140G, 160G, 769, 772
4D4221
SPRING
120, 120B, 12E, 140, 140B, 14E, 777, D300D
120, 120B, 12E, 140, 140B, 14E, 777, D300D
3P0812
SPRING
120G, 12G, 130G, 140G, 160G, D9R, D9T
120G, 12G, 130G, 140G, 160G, D9R, D9T
2D2125
SPRING
120B, 12E, 140B, D8H
120B, 12E, 140B, D8H
3P0817
SPRING-DISC
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
2P5701
SPRING
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA
6G6122
SPRING-DISC
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
4D1605
SPRING
120, 120B, 12E, 140, 140B, 14E
120, 120B, 12E, 140, 140B, 14E
6N4164
SPRING
3408, 3408B, 3412, 631E, 637D, 637E, 651E, 657E, 769C, 771C, 834B, PM-565
3408, 3408B, 3412, 631E, 637D, 637E, 651E, 657E, 769C, 771C, 834B, PM-565
7M7316
SPRING
12E, 16, 1673, 1673B, 1673C, 1674, 1676, 1693, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 561B, 561C, 578, 583R, 589, 621, 627, 631E, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 768C, 769C, 771C, 772, 772B...
12E, 16, 1673, 1673B, 1673C, 1674, 1676, 1693, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 561B, 561C, 578, 583R, 589, 621, 627, 631E, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 768C, 769C, 771C, 772, 772B...
2S3992
SPRING
1674, 1676, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3606, 3608, 3612, 3616, 621, 650B, 772, 773, 777, 980, 992, C15, C18, C30, C32, C4.4, C9, D346...
1674, 1676, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3606, 3608, 3612, 3616, 621, 650B, 772, 773, 777, 980, 992, C15, C18, C30, C32, C4.4, C9, D346...
9N5078
SPRING
3408, 3408C, 3412, 3412C, 3412D, 637D, 657E, 992C, PM-565
3408, 3408C, 3412, 3412C, 3412D, 637D, 657E, 992C, PM-565
9N5077
SPRING
3408, 3408C, 3412, 3412C, 3412D, 3608, 637D, 657E, 992C, PM-565
3408, 3408C, 3412, 3412C, 3412D, 3608, 637D, 657E, 992C, PM-565
8N9000
SPRING
3412, 824G, 824G II, 824H, 825G, 825G II, 825H, 826G, 826G II, 826H, 836G, 836H, 950G, 962G, 980G, 980G II, 980H, AD55B, AD60
3412, 824G, 824G II, 824H, 825G, 825G II, 825H, 826G, 826G II, 826H, 836G, 836H, 950G, 962G, 980G, 980G II, 980H, AD55B, AD60
5N4112
SPRING-TORSION
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
3N5723
SPRING
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
7N6052
SPRING AS-SPEED
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
3304, 3306, 3406, 3406B, 3408, 3408B, 3412, G3306, G3406, G3408, G3412, G342C
9S4982
SPRING
120G, 14G, 245, 3408, 3408B, 3412, D10, D353C, D4D, D6C, D7F, D9H, D9L
120G, 14G, 245, 3408, 3408B, 3412, D10, D353C, D4D, D6C, D7F, D9H, D9L
8M8403
SPRING-GUIDE
120, 16, 1673C, 1674, 1676, 1693, 16G, 245, 3304, 3306, 3406, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 561C, 589, 621, 621B, 621R, 623, 627, 631C, 631E, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 769C, ...
120, 16, 1673C, 1674, 1676, 1693, 16G, 245, 3304, 3306, 3406, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 561C, 589, 621, 621B, 621R, 623, 627, 631C, 631E, 637D, 637E, 641B, 650B, 651E, 657B, 657E, 769C, ...
6N8793
SPRING
3408, 3408B, 3408C, 3412, 3412C, 3412D, 589, 631E, 637D, 637E, 651E, 657E, 769C, 771C, 772B, 773B, 775B, 834B, 988B, 988F, 990, 992C, 992D, D10N, D8L, D9L, D9N, D9R, PM-565, PR-1000, PR-450C, PR-750B
3408, 3408B, 3408C, 3412, 3412C, 3412D, 589, 631E, 637D, 637E, 651E, 657E, 769C, 771C, 772B, 773B, 775B, 834B, 988B, 988F, 990, 992C, 992D, D10N, D8L, D9L, D9N, D9R, PM-565, PR-1000, PR-450C, PR-750B