Schematic of the solenoid valve (ride control)
This diagnostic code is associated with the solenoid valve (ride control). The FMI 05 means that the ECM has determined that the current of the solenoid is below normal. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open
The return circuit of the solenoid is open
The solenoid has failed
The ECM may have failed, but is unlikelyNote: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0363 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, the ride control function is inoperable.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoids, place a jumper wire from contact 1 (wire 976-OR(Orange)) to contact 2 (wire 200-BK(Black)).
Observe the status of the CID 0363 FMI 05. Expected Result:The CID 0363 FMI 05 remains active. The FMI has not changed and the "05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J1-67 (wire 976-OR(Orange)) to frame ground (wire 200-BK(Black)). Expected Result:The resistance is less than 5 ohms.Results:
YES - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step 3.
NO - The resistance is greater than 5 ohms. The resistance measurement is not correct.Repair: The problem is in wire 976-OR(Orange) or in wire 200-BK(Black) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0363 FMI 05. Expected Result:The CID 0363 FMI 05 is active. Results:
YES - The CID 0363 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: The ECM is unlikely to have failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts sprocket Caterpillar catalog:
8P8121
SPROCKET GP
983, 983B
983, 983B
6P8688
SPROCKET SEGMENT GROUP
977K, D7G
977K, D7G
2004196
SPROCKET GP-NONSEGMENTED
322C, 324D FM, OEMS
322C, 324D FM, OEMS
2047171
SPROCKET GP
345B, 345C
345B, 345C
8P8170
SPROCKET GP-SEGMENTED
571G, 572G, D7G
571G, 572G, D7G
2589802
SPROCKET
953C
953C
6I7549
SPROCKET GP
5230, 5230B
5230, 5230B
6I7229
SPROCKET GP
5130, 5130B
5130, 5130B
1074897
SPROCKET GP-NONSEGMENTED
322 FM L, 325 FM L, 325 L
322 FM L, 325 FM L, 325 L