Information:
Engine3512E (S/N: MR21-UP; MD31-UP; MR31-UP; MR41-UP; MR71-UP; MR81-UP)3516E (S/N: MD51-UP; MR91-UP; MRC1-UP; MRN1-UP; MRY1-UP)Introduction
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Download and Store the ECM History File
Illustration 1 g06274453Reference: Operation & Maintenance Manual, M0065584, Connect to the PLE601 EPA Datalogger for instructions on how to retrieve the history file.Note: Print and retain the contents of the file and keep on the vessel for a period no less than one year.Checking DCU Firmware
Illustration 2 g06274499
Connect to the DCU following the instructions from LEBM0063 starting on page 9.
Click "Version" on the left side.
Illustration 3 g06274508
Verify that the DCU is 3.5 P2 or newer.Loading New Firmware to DCU
Illustration 4 g06274513
Download the 541-0882 Monitor Software Gp (3.6) or latest firmware from SIS web.
Illustration 5 g06274514
Navigate to "DCU" to "File" to "Upload to DCU".
Illustration 6 g06274517
Click "Firmware" on the left side.
Select the firmware that was saved to the PC from SIS web.
Click the "Upgrade" button.Adding a Screen to the DCU for Accumulative Counters
Illustration 7 g06274521
Make sure that the Accumulative Counters (SPN’s 6817, 8327, and 6818) are configured for use on the DCU/RP.
Navigate to "DCU" to "I/O Configuration" to "J1939/J1939#2" and search for the Accumulative Counters.
Illustration 8 g06274531
Set the "Channel Use" to "DCU + RP" if it is not already.
Click the "Submit" button.
Repeat the previous steps for remaining SPN’s for both J1939#1 and J1939#2.
Illustration 9 g06274633
Click "User Interface".
Illustration 10 g06274634
Click "Pages"
Click "Insert Page".
Illustration 11 g06274638
Using template 24, add the Accumulative Counters to Page shown in Illustration 11.
Click "Submit".
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.Safety Section
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.
Download and Store the ECM History File
Illustration 1 g06274453Reference: Operation & Maintenance Manual, M0065584, Connect to the PLE601 EPA Datalogger for instructions on how to retrieve the history file.Note: Print and retain the contents of the file and keep on the vessel for a period no less than one year.Checking DCU Firmware
Illustration 2 g06274499
Connect to the DCU following the instructions from LEBM0063 starting on page 9.
Click "Version" on the left side.
Illustration 3 g06274508
Verify that the DCU is 3.5 P2 or newer.Loading New Firmware to DCU
Illustration 4 g06274513
Download the 541-0882 Monitor Software Gp (3.6) or latest firmware from SIS web.
Illustration 5 g06274514
Navigate to "DCU" to "File" to "Upload to DCU".
Illustration 6 g06274517
Click "Firmware" on the left side.
Select the firmware that was saved to the PC from SIS web.
Click the "Upgrade" button.Adding a Screen to the DCU for Accumulative Counters
Illustration 7 g06274521
Make sure that the Accumulative Counters (SPN’s 6817, 8327, and 6818) are configured for use on the DCU/RP.
Navigate to "DCU" to "I/O Configuration" to "J1939/J1939#2" and search for the Accumulative Counters.
Illustration 8 g06274531
Set the "Channel Use" to "DCU + RP" if it is not already.
Click the "Submit" button.
Repeat the previous steps for remaining SPN’s for both J1939#1 and J1939#2.
Illustration 9 g06274633
Click "User Interface".
Illustration 10 g06274634
Click "Pages"
Click "Insert Page".
Illustration 11 g06274638
Using template 24, add the Accumulative Counters to Page shown in Illustration 11.
Click "Submit".
Parts sprocket Caterpillar catalog:
5J9253
SPROCKET
Caterpillar
Caterpillar
5J3836
SPROCKET
Caterpillar
Caterpillar
5J3833
SPROCKET
Caterpillar
Caterpillar
5I4900
SPROCKET
Caterpillar
Caterpillar
5I4746
SPROCKET
Caterpillar
Caterpillar
5H7835
SPROCKET A.
Caterpillar
Caterpillar
5M7747
SPROCKET A.
Caterpillar
Caterpillar
5M6635
SPROCKET A.
Caterpillar
Caterpillar
5M6634
SPROCKET
Caterpillar
Caterpillar
5K5857
SPROCKET G.
Caterpillar
Caterpillar
5K5618
SPROCKET
Caterpillar
Caterpillar
5K3433
SPROCKET
Caterpillar
Caterpillar