8M5000 SPROCKET ASSEM. (SNOW) Caterpillar parts
977H
Rating:
Alternative (cross code) number:
CA8M5000
8M-5000
8M5000
CA8M5000
8M-5000
8M5000
Weight: 32 pounds 14 kg.
TRACK LOADER,
Compatible equipment models: 8M5000:
Information:
1N9406 30 or 32V (Delco-Remy Number 1117237)
Polarity is negative ground.Circuit ... BSpeed for testing ... 5000 rpmRotation can be either direction.Output when cold:Fasten carbon pile to battery to get maximum output ... 54 ARated output, hot ... 50 AField current at 32 V and 80°F (27°C) ... 1.6 to 1.7 AVoltage regulator:Voltage setting range ... 33.7 to 37.7 VAdjust voltage setting to: for 32 V operation ... 36.7 Vfor 30 V operation ... 34.7 Vthen increase speed to get maximum output ... 50 A(1) Torque for nut holding pulley ... 75 5 lb. ft.(100 7 N m)(2) Torque for output terminal ... 10 1 lb. ft.(14 1 N m)Torque for "ground" terminal on top of alternator ... 50 to 60 lb. in.(5.7 to 6.8 N m)5S9088 24V (Delco-Remy Number 1117226 or 1117236)
Polarity is negative ground.Circuit ... BSpeed for testing ... 5000 rpmRotation can be either direction.Output when cold: Fasten carbon pile to battery to get maximum output ... 54 ARated output, hot ... 50 AField current at 24 V and 80°F (27°C) ... 2.5 to 2.9 AVoltage regulator: Voltage setting range ... 26 to 30 VAdjust voltage setting to ... 28 Vthen increase speed to get maximum output ... 50 A(1) Torque for nut holding pulley ... 75 5 lb. ft.(100 7 N m)(2) Torque for output terminal ... 10 1 lb. ft.(14 1 N m)Torque for bolts holding bottom of alternator to bracket ... 24 3 lb. ft.(30 4 N m)Torque for bolt holding top of alternator to adjusting strap ... 56 7 lb. ft.(75 10 N m)
Polarity is negative ground.Circuit ... BSpeed for testing ... 5000 rpmRotation can be either direction.Output when cold:Fasten carbon pile to battery to get maximum output ... 54 ARated output, hot ... 50 AField current at 32 V and 80°F (27°C) ... 1.6 to 1.7 AVoltage regulator:Voltage setting range ... 33.7 to 37.7 VAdjust voltage setting to: for 32 V operation ... 36.7 Vfor 30 V operation ... 34.7 Vthen increase speed to get maximum output ... 50 A(1) Torque for nut holding pulley ... 75 5 lb. ft.(100 7 N m)(2) Torque for output terminal ... 10 1 lb. ft.(14 1 N m)Torque for "ground" terminal on top of alternator ... 50 to 60 lb. in.(5.7 to 6.8 N m)5S9088 24V (Delco-Remy Number 1117226 or 1117236)
Polarity is negative ground.Circuit ... BSpeed for testing ... 5000 rpmRotation can be either direction.Output when cold: Fasten carbon pile to battery to get maximum output ... 54 ARated output, hot ... 50 AField current at 24 V and 80°F (27°C) ... 2.5 to 2.9 AVoltage regulator: Voltage setting range ... 26 to 30 VAdjust voltage setting to ... 28 Vthen increase speed to get maximum output ... 50 A(1) Torque for nut holding pulley ... 75 5 lb. ft.(100 7 N m)(2) Torque for output terminal ... 10 1 lb. ft.(14 1 N m)Torque for bolts holding bottom of alternator to bracket ... 24 3 lb. ft.(30 4 N m)Torque for bolt holding top of alternator to adjusting strap ... 56 7 lb. ft.(75 10 N m)
Caterpillar parts catalog:
Parts sprocket Caterpillar catalog:
5M9163
SPROCKET
12E, 824, 955H, 977H
12E, 824, 955H, 977H
5S0727
SPROCKET GROUP
561C, D5
561C, D5
6S3169
SPROCKET
931, D3
931, D3
2K5165
SPROCKET
572G, 583H, 583K, 594, 594H
572G, 583H, 583K, 594, 594H
2K1678
SPROCKET (11T)
572G, 583H, 594, 594H
572G, 583H, 594, 594H
1K3379
SPROCKET
561C, 571G
561C, 571G
6K1735
SPROCKET ASSEM.
955K, 955L
955K, 955L