7E9454 STABILIZER AS Caterpillar parts
793, 793B, 793C, 797, 797B
Rating:
Alternative (cross code) number:
CA7E9454
7E-9454
7E9454
CA7E9454
7E-9454
7E9454
Weight: 12 pounds 5 kg.
TRUCK,
Information:
Illustration 10 g06175747
Install Tool (H) in adapter (14) in the vibratory motor.
Install Tool (E) from inlet side of Tool (B) onto Tool (H).
Install Tool (J) onto adapter (13).
Install Tool (E) from outlet side of Tool (B) onto Tool (J).
Move engine start switch (8) to the START position. Release the switch when the engine starts.
Operate the engine at low idle for a few minutes then place the engine in high idle.
Operate the hydraulic system until the oil temperature reaches the test temperature of 45 °C (113 °F).
Move parking brake switch (2) to the OFF position.
Illustration 11 g06170108
Use vibratory frequency switch (15) to set the vibratory system in the low frequency/high amplitude mode.Note: Two things indicate when the vibratory system is in the low frequency/high amplitude mode. First, "Vibe Frequency Mode Low" will appear on the display. Second, one LED next to vibratory frequency switch (15) will be illuminated.
Illustration 12 g06170114
If necessary, use drum select switch (16) to select both drums.Note: Two things indicate when the machine is in dual drum mode. First, "Vibe Drum Select Dual" will appear on the display. Second, both LEDs next to drum select switch (16) will be illuminated.
Set the vibratory system in the manual mode.
Illustration 13 g06148594
Select "Main Menu" (17) on the machine display.
Select "Machine Setup" (18).
Illustration 14 g06148596
Select "Vibe Turn On Speed" (19).
Illustration 15 g06148599
Select "Manual" mode (20).
Launch the Plus+1TM program on the computer to enable the vibe test mode.Note: First-time users need to perform the tasks in the Communication and Connections Wizard. This wizard allows the Windows® operating system to recognize the USB device. Follow the on-screen instructions.
Illustration 16 g06153168
Click "Status" icon (21).
Check for "Active Codes". Clear any open "Active Codes".
Click "Machine Control" (22).
Illustration 17 g06153171
Click "Hydraulics" (23).
Click "Vibe Test Modes" (24).
Illustration 18 g06163464
Click "Enable" icon (25) to enable the "Normal Vibe Test Mode".
When "Normal Vibe Test Mode" is in "Enabled" mode, the Plus+1TM program is launched.
Illustration 19 g06170121
Press vibratory control switch (26) on the propel lever. The vibratory control switch must be held in the ON position for at least 2 seconds for the vibratory system to actuate.
Read flow on Tool (B). The flow should be
Caterpillar parts catalog:
Parts stabilizer Caterpillar catalog:
1008025
STABILIZER AS
994, 994D
994, 994D
7E2715
STABILIZER AS
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 793C, 994
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 793C, 994
3749481
STABILIZER AS
795F AC, 795F XQ
795F AC, 795F XQ
3749479
STABILIZER AS
795F AC, 795F XQ
795F AC, 795F XQ
2881652
STABILIZER AS
789C, 789D, 795F AC, 795F XQ, 797F
789C, 789D, 795F AC, 795F XQ, 797F
1783314
STABILIZER AS
735, 740, D350E II, D400E II
735, 740, D350E II, D400E II
1783317
STABILIZER AS
D350E II, D400E II
D350E II, D400E II