Information:
Illustration 7 g03515942
Single-phase, two-wire, L2-L3, zig-zag configuration
Transformer Connections
In order to monitor the generator output voltages greater than 600V, potential transformers (PTs) must be used.Note: The EMCP 4 must be programmed when connecting external PTs. Reference: Systems Operation, "Setpoint Programming" and Testing and Adjusting, "Electronic Control Module (Generator Set) - Configure".Note: The wye configuration of external PTs is preferred for 4-wire wye generators because of the greater accuracy when loads are unbalanced. With the open delta configuration, some power parameters cannot be determined. These parameters are real power phase A, B, C, and power factor phase A, B, C. For maximum accuracy, the open delta configuration of external PTs should be used only for 3-wire delta generators.
Illustration 8 g02286873
Four-wire Wye (Star) configuration
Illustration 8 is a typical example of a Wye configuration of an external potential transformer for the four wire Wye generator.This configuration allows the accurate measurement of all power parameters by the EMCP 4 including when the loads are unbalanced and neutral current is present. All power parameters are shown on the display of the EMCP 4. The EMCP 4 configuration parameter " Generator Connection Configuration" should be set to WYE (or STAR).
Illustration 9 g02286876
Three-phase, three-wire, delta configuration
Open delta configuration of external potential transformers on the 3-wire delta generatorThis configuration allows the accurate measurement of power parameters by the EMCP 4 including when the loads are unbalanced and circulating current is present. The real power phase A, B, and C cannot be determined. The power factor phase A, B, and C cannot be determined. The phases are not shown on the EMCP 4 display. The EMCP 4 configuration parameter "Generator Connection Configuration" should be set to DELTA (3 WIRE).
Illustration 10 g02286877
Three-phase, four-wire, delta configuration
The three phase four-wire is also referred to as the open delta configuration for external potential transformers on the 4-wire wye generator.The three phase four wire configuration results in less accurate measurement of all power parameters by the EMCP 4. Less accurate measurement occurs when the loads are unbalanced and neutral current is present. Real power phase A, B, C and power factor phase A, B, C cannot be determined and are not shown on the EMCP 4 display. The EMCP 4 configuration parameter "Generator Connection Configuration" should be set to DELTA (3 WIRE).On 4-wire wye generators, three separate PTs are required for accurate power metering unless the loads are completely and continually balanced. Even if the loads are balanced, some power parameters cannot be determined. Real power phase A, B, C, and power factor phase A, B, C are not shown on the EMCP 4 display.On 3-wire delta generators, two PTs allow maximum accuracy for all load conditions. Real power phase A, B, C and power factor phase A, B, C cannot be determined and are not shown on the EMCP 4 display.
Table 1
Transformer Connections
Parameter Star 3-WIRE DELTA 4-WIRE DELTA 2-WIRE 1-PHASE 3-WIRE 1-PHASE
Generator Freq OK OK OK OK OK
VL-L AVG OK OK OK OK OK
VA-B OK OK OK OK OK
VB-C OK OK OK Invalid Invalid
VC-A OK OK
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts starting Caterpillar catalog:
1430539
STARTING MOTOR GP-ELECTRIC
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 3054C, 414E, 416C, 416D, 416E, 416F, 42...
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 3054C, 414E, 416C, 416D, 416E, 416F, 42...
2370024
STARTING MOTOR GP-ELECTRIC
3054C, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 442E, 444E, 444F
3054C, 414E, 416D, 416E, 416F, 420D, 420E, 420F, 422E, 422F, 424D, 428D, 428E, 428F, 430D, 430E, 430F, 432D, 432E, 432F, 434E, 434F, 442D, 442E, 444E, 444F
2349666
STARTING MOTOR GP-ELECTRIC
3054C, 3054E, C4.4, TH210, TH215
3054C, 3054E, C4.4, TH210, TH215
3644130
STARTING MOTOR GP-ELECTRIC
3054, 3054B, 3054C, 3054E, 3056, 3056E, AP-300, AP-300D, C3.3, C4.4, C6.6, CB-434D, CB-54, CB-64, CD-54, SPF343C, TH210, TH215
3054, 3054B, 3054C, 3054E, 3056, 3056E, AP-300, AP-300D, C3.3, C4.4, C6.6, CB-434D, CB-54, CB-64, CD-54, SPF343C, TH210, TH215
2253150
STARTING MOTOR GP-ELECTRIC
3054C, 3054E, 3056E, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 315C, 318D2 L, 420D, 420E, 564, 574B, 914G, AP-650B, AP-800D, AP555E, BB-760, BG500E, C4.4, C6.6, CP-433E, CP-44, CP-533E, CS-323C, CS-...
3054C, 3054E, 3056E, 312D2, 312D2 GC, 312D2 L, 313D2, 313D2 LGP, 315C, 318D2 L, 420D, 420E, 564, 574B, 914G, AP-650B, AP-800D, AP555E, BB-760, BG500E, C4.4, C6.6, CP-433E, CP-44, CP-533E, CS-323C, CS-...
3290290
STARTING MOTOR GP-ELECTRIC
3054C, C4.4
3054C, C4.4
4202433
STARTING MOTOR GP-ELECTRIC
320D GC, 320D L, 323D L
320D GC, 320D L, 323D L
2T3380
STARTING AID GP-ETHER
611, 615C
611, 615C
1130677
STARTING AID GP-ETHER
773D, 775D
773D, 775D
1714654
STARTING AID AR-ETHER
824G II, 825G II, 826G II
824G II, 825G II, 826G II
2679535
STARTING MOTOR GP-ELECTRIC
C13, CX31-C13I, TH35-C13I
C13, CX31-C13I, TH35-C13I
3849430
STARTING AR-COLD WEATHER
621H, 623H, 627H
621H, 623H, 627H