2337564 STATOR-CONVERTER Caterpillar parts
24M, 735, 735B, 740, 740B, 769C, 769D, 770, 770G, 770G OEM, 771C, 771D, 772, 772G, 772G OEM, 773D, 773E, 773F, 773G LRC, 773G OEM, 775E, 775F, 775G LRC, 775G OEM
Rating:
Alternative (cross code) number:
CA2337564
233-7564
2337564
CA2337564
233-7564
2337564
Weight: 8 pounds 4 kg.
ARTICULATED TRUCK, TRUCK,
This part in 2 request:
Show.
This information for suppliers only!
2020-07-17
2020-04-23
Compatible equipment models: 2337564:
Information:
Jump sources higher than system voltage of the stalled engine are sometimes thought to give better cranking speeds and subsequent startability. Higher-than-rated jump sources cause damage to starters, batteries, and other electrical components. Batteries can also explode causing personal injury. NEVER jump with a source higher than the system of the stalled engine. Use a 12V source on a 12V system and 24V on 24V system, etc.
2. When the alternator voltage regulator is shorted, causing full (rated) charging current, AND an open circuit or loose connection exists in the charging circuit.The regulator adjusts alternator output by varying field current to maintain correct system voltage. Regulators have, mainly, two failure modes: open or shorted. When open, there is no field current and no alternator output. If shorted, field current is maximum causing maximum rated, uncontrolled, output current, provided the engine is running at or above about 75% of rated engine speed.
Batteries serve two main functions in ANY electrical system:
1. Provide energy for cranking the engine.2. Act as an accumulator to provide a "smoothing" effect for electrical system voltage variations.Alternators serve two main functions in ANY electrical system:
1. To recharge batteries after an engine startup.2. To supply ALL electrical system requirements after the engine is running.If all connections are tight, full alternator output will, first, cause battery damage. Batteries become the "load" for a runaway alternator. They absorb alternator current that is above what is required for normal machine operation. This high current causes battery damage from excessive: electrolyte temperatures, plate warping, and water loss. As the electrolyte level (water) drops, the chance of battery explosion increases and system voltage will also increase out of control. The result is damage to other electrical system components like relays, lighting and electronic controls.
Full alternator output with loose or poor connections in the charging circuit (even with batteries in good condition) can cause immediate high voltage damage to electrical system components. Loose or poor connections, such as at the battery terminals, can cause short periods of an "open circuit," which has the same result as batteries with low electrolyte. Opening the disconnect during an overcharging condition also has the same effect as a loose connection.
The following are clues to high charging system voltage due to voltage regulator failure:
1. More than one lighting component blackened or dead. One or more electronic controls dead.2. Electrolyte level low in ALL cells of ALL batteries.3. If engine is operational, charging voltage measures over 29.0 volts (or over 15.0 volts for 12V systems). The following are clues to incorrect jump starting:
1. More than one lighting component blackened or dead. One or more electronic controls functioning incorrectly.2. One or more batteries exploded. Electrolyte level in undamaged cells appears normal.3. If engine is operational, charging voltage appears normal. If alternator was damaged by reverse hookup of jump source, the most likely failure would be low or no alternator output.
Cat SIS web machinery list:
Parts stator Caterpillar catalog:
9S2004
STATOR AS
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
7T6418
STATOR AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 245, 3114, 3116, ...
3T1886
STATOR AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 245, 3114, 3116, 3126,...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 245, 3114, 3116, 3126,...
1900065
STATOR AS-ALTERNATOR
120H, 120H ES, 12G, 12H, 12H ES, 135H, 135H NA, 140G, 140H ES, 16G, 16H NA, 3114, 3116, 3126B, 3176C, 3208, 330, 3304, 3306, 3306B, 330B L, 3406C, 3412, 3412C, 345B, 527, 528B, 530B, 583R, 587R, 589, ...
120H, 120H ES, 12G, 12H, 12H ES, 135H, 135H NA, 140G, 140H ES, 16G, 16H NA, 3114, 3116, 3126B, 3176C, 3208, 330, 3304, 3306, 3306B, 330B L, 3406C, 3412, 3412C, 345B, 527, 528B, 530B, 583R, 587R, 589, ...
2028647
STATOR AS
120H, 12H, 135H, 140H, 143H, 14H, 160H, 163H, 16H, 3126B, 3516B, 621B, 621G, 623G, 627F, 627G, 631D, 631E, 631G, 637D, 637E, 637G, 651B, 657B, 657E, 657G, 725, 730, 735B, 740, 740B, 826G II, AP-655C, ...
120H, 12H, 135H, 140H, 143H, 14H, 160H, 163H, 16H, 3126B, 3516B, 621B, 621G, 623G, 627F, 627G, 631D, 631E, 631G, 637D, 637E, 637G, 651B, 657B, 657E, 657G, 725, 730, 735B, 740, 740B, 826G II, AP-655C, ...
1852642
STATOR AS
3126B, 322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330C, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406E, 34...
3126B, 322C, 324D, 324D L, 324D LN, 325C, 325D, 325D L, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330C, 330C L, 330C MH, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3406E, 34...
2050626
STATOR AS-ALTERNATOR
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 1390, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 16...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 1390, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 16...
1567239
STATOR
583T, 725, 725C, 730, 735, C9, D8R II, D8T, PL83, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
583T, 725, 725C, 730, 735, C9, D8R II, D8T, PL83, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
1482974
STATOR-CONVERTER
24H, 24M, 651E, 657E, 657G, 988F II, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II
24H, 24M, 651E, 657E, 657G, 988F II, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II
1T0943
STATOR
657B, 769C, 773B, 824B, 834, 992
657B, 769C, 773B, 824B, 834, 992
1480885
STATOR-CONVERTER
69D, 740, 769C, 773B, 773D, 773E, 775B, 775D, D350E, D350E II, D400E, D400E II
69D, 740, 769C, 773B, 773D, 773E, 775B, 775D, D350E, D350E II, D400E, D400E II
1T1752
STATOR-CONVERTER
769C, 773B, D35HP, D400, D40D
769C, 773B, D35HP, D400, D40D
1480885
STATOR-CONVERTER
69D, 740, 769C, 773B, 773D, 773E, 775B, 775D, D350E, D350E II, D400E, D400E II
69D, 740, 769C, 773B, 773D, 773E, 775B, 775D, D350E, D350E II, D400E, D400E II
1T1938
STATOR-CONVERTER
784B, 784C, 785, 785B, 785C
784B, 784C, 785, 785B, 785C
1T1937
STATOR-CONVERTER
776C, 776D, 777B, 777D
776C, 776D, 777B, 777D
9U9599
STATOR-CONVERTER
789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
789D, 793, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ
1T1834
STATOR
24H, 988F II
24H, 988F II
3840711
STATOR
824K, 825K, 826K, 982M
824K, 825K, 826K, 982M
3007742
STATOR AS
795F AC, 795F XQ
795F AC, 795F XQ
2836763
STATOR AS
795F AC, 795F XQ
795F AC, 795F XQ
1396166
STATOR-CONVERTER
797, 797B, 797F
797, 797B, 797F
1409957
STATOR AS
725, 725C, 730
725, 725C, 730
1482972
STATOR-CONVERTER
784C, 785C, 785D
784C, 785C, 785D
9W7641
STATOR-RETARDER
D250D, D250E, D250E II, D25C, D25D, D300E, D300E II, D350E, D400E, D40D
D250D, D250E, D250E II, D25C, D25D, D300E, D300E II, D350E, D400E, D40D