1417231 STEM AS-LIFT Caterpillar parts
D6R
Rating:
Alternative (cross code) number:
CA1417231
141-7231
1417231
CA1417231
141-7231
1417231
Weight: 1 pounds 0 kg.
TRACK-TYPE TRACTOR,
Compatible equipment models: 1417231:
Information:
Checking Before Start-Up
Check the battery charger for proper operation. If the batteries are properly charged, the needle of the ammeter will register near "0" (zero).The battery charger must not produce excessive current during start-up. Alternatively, automatically disconnect the charger for start-up.Charging the Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
Perform the following procedure to charge the battery:
Ensure that the charger is turned OFF.
Adjust the voltage of the charger in order to match the voltage of the battery.
Connect the POSITIVE "+" lead of the charger to the POSITIVE "+" battery terminal. Connect the NEGATIVE "-" lead of the charger to the NEGATIVE "-" battery terminal.
Turn ON the battery charger. Overcharging of Batteries
Overcharging reduces the service life of batteries. Use a battery charger that will not overcharge the battery. DO NOT charge the battery if the meter of the battery charger is in the RED zone.Overcharging is indicated by the following symptoms:
The battery is warm to the touch.
A strong odor of acid is present.
The battery emits smoke or a dense vapor (gas).Perform one of the following procedures if the battery shows symptoms of overcharging:
Reduce the rate of charging by a significant amount. Complete the charging at the reduced rate.
Turn OFF the charger.Table 1 describes the effects of overcharging on different types of batteries.
Table 1
Effects of Overcharging Batteries
Type of Battery Effect
Caterpillar General Service Batteries
Caterpillar Premium High Output Batteries All of the battery cells have a low level of electrolyte.
When the plates of the battery are inspected through the filler holes, the plates may appear to be warped. This condition is caused by an excessive temperature.
The battery may not pass a load test.
Caterpillar Maintenance Free Batteries The battery may not accept a charging current.
The battery may not pass a load test. Checking After Stopping
Ensure that the battery charger is connected properly. Observe the meter of the charger. Record the amperage.
Check the battery charger for proper operation. If the batteries are properly charged, the needle of the ammeter will register near "0" (zero).The battery charger must not produce excessive current during start-up. Alternatively, automatically disconnect the charger for start-up.Charging the Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
Perform the following procedure to charge the battery:
Ensure that the charger is turned OFF.
Adjust the voltage of the charger in order to match the voltage of the battery.
Connect the POSITIVE "+" lead of the charger to the POSITIVE "+" battery terminal. Connect the NEGATIVE "-" lead of the charger to the NEGATIVE "-" battery terminal.
Turn ON the battery charger. Overcharging of Batteries
Overcharging reduces the service life of batteries. Use a battery charger that will not overcharge the battery. DO NOT charge the battery if the meter of the battery charger is in the RED zone.Overcharging is indicated by the following symptoms:
The battery is warm to the touch.
A strong odor of acid is present.
The battery emits smoke or a dense vapor (gas).Perform one of the following procedures if the battery shows symptoms of overcharging:
Reduce the rate of charging by a significant amount. Complete the charging at the reduced rate.
Turn OFF the charger.Table 1 describes the effects of overcharging on different types of batteries.
Table 1
Effects of Overcharging Batteries
Type of Battery Effect
Caterpillar General Service Batteries
Caterpillar Premium High Output Batteries All of the battery cells have a low level of electrolyte.
When the plates of the battery are inspected through the filler holes, the plates may appear to be warped. This condition is caused by an excessive temperature.
The battery may not pass a load test.
Caterpillar Maintenance Free Batteries The battery may not accept a charging current.
The battery may not pass a load test. Checking After Stopping
Ensure that the battery charger is connected properly. Observe the meter of the charger. Record the amperage.
Caterpillar parts catalog:
Parts stem Caterpillar catalog:
1K2591
STEM
943, 963, 973
943, 963, 973
3G8447
STEM
943, 953, 963, 963B, 973
943, 953, 963, 963B, 973
2Y4986
STEM
977, D4E, D4E SR
977, D4E, D4E SR
6S3168
STEM
D3, D4E, D4E SR
D3, D4E, D4E SR
8Y5339
STEM
931C, 933
931C, 933
1465707
STEM
D3C III, D5C III
D3C III, D5C III
2547184
STEM
D6K LGP, D6K XL, D6K2, D6K2 LGP
D6K LGP, D6K XL, D6K2, D6K2 LGP
2547185
STEM AS
D6K LGP, D6K XL, D6K2, D6K2 LGP
D6K LGP, D6K XL, D6K2, D6K2 LGP
1U2073
STEM
D6N, D6T
D6N, D6T
2327334
STEM-TILT
973C
973C
7N8294
STEM
16H NA, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824G, 825G, 826C, 826G, 980C, 980G, D350E, D400, D400E, D8N, D8R, D8R II
16H NA, 578, 583R, 587R, 621F, 623E, 623F, 627B, 627F, 814B, 824G, 825G, 826C, 826G, 980C, 980G, D350E, D400, D400E, D8N, D8R, D8R II
2327333
STEM-TILT
963C
963C