1664113 STEP Caterpillar parts
D10N, D10R, D10T, D10T2, D11R, D11T, D7E LGP, D9T
Rating:
Alternative (cross code) number:
CA1664113
166-4113
1664113
CA1664113
166-4113
1664113
Weight: 39 pounds 18 kg.
TRACK-TYPE TRACTOR,
This part in 4 request:
Show.
This information for suppliers only!
2024-06-26
2020-08-20
2020-05-13
2020-01-30
Compatible equipment models: 1664113:
Information:
Starting the Fault Diagnosis
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Illustration 1 g02338096
Control Panel (1a) Temperature select switch (increase) (1b) Temperature select switch (decrease) (2) Air inlet select switch (3) Main power On/Off switch (4) Display of set temperature (5) Defrost switch
Turn the engine start switch to ON.
Turn main power switch (3) of the air conditioner to OFF.
Depress temperature select switch (increase) (1a) and the temperature select switch (decrease) (1b) on the control panel at the same time. Hold both switches down for at least 3 seconds.
The diagnosis procedure shall start. If any error is memorized, the smallest error code is displayed on display (4) . If no problems exist, "E-.-" is displayed.
When the temperature select switch (increase) (1a) is depressed, error codes are displayed. The error codes are displayed in ascending order from "E11" to "E45". When the temperature select switch (decrease) (1b) is depressed, error codes are displayed. The error codes are displayed in descending order from "E45" to "E11".Note: When only one error code exists, the same display is repeated. A flashing display means that the error code is continuing from the past. A non-flashing display means that the error code was found in the past, but the error code is not found now.
When the fault diagnosis is running, the control of each function is altered.
All outputs from the control panel except error codes are turned OFF.
The panel light turns ON.
Clear the error codes. Depress air inlet select switch (2) and defrost switch (5 ) on the control panel at the same time. Hold both switches down for at least 3 seconds.Note: Clear any error codes when the equivalent problems have been repaired. Make sure that the same error code is not displayed again. When a problem has not yet been repaired, the equivalent error code should be displayed again.Ending the Fault Diagnosis
There are two ways to end the fault diagnosis.
Press main power switch (3) .
Turn the engine start switch to OFF.Error Codes
Table 1
Control Panel Diagnostic Error Codes    
Code    Problem Area    Problem    
"E11"     Intake air temperature sensor     Open circuit    
"E12"     Intake air temperature sensor     Short circuit    
"E13"     Ambient air temperature sensor     Open circuit    
"E14"     Ambient air temperature sensor     Short circuit    
"E15"     Water temperature sensor     Open circuit    
"E16"     Water temperature sensor     Short circuit    
"E21"     Evaporator sensor     Open circuit    
"E22"     Evaporator sensor     Short circuit    
"E33"     Air outlet motor     Open/Short circuit    
"E34"     Air blend motor     Open/Short circuit    
"E35"     Air inlet motor     Open/Short circuit    
"E43"     Damper for air outlet     No movement    
"E44"     Damper for air blend     No movement    
"E45"     Damper for air inlet     No movement    
"E51"     Refrigerant Pressure     High/Low error    Inspecting a Wiring Harness
Electrical problems are often caused by faulty electrical wires that have either an open circuit or a short circuit. The following procedures explain the test
Cat SIS web machinery list:
Parts step Caterpillar catalog:
7T5140
STEP
14G, D10N, D11N, D11R, D6T LGP, D6T XL, D7E, D8N, D8R, D8R II, D8T, D9N, D9R, D9T
14G, D10N, D11N, D11R, D6T LGP, D6T XL, D7E, D8N, D8R, D8R II, D8T, D9N, D9R, D9T
3654168
STEP AS
D7E, D7E LGP
D7E, D7E LGP
3769890
STEP
D7E, D7E LGP
D7E, D7E LGP
3374149
STEP
D9T
D9T
3374148
STEP
D9T
D9T
3552889
STEP AS
D9T
D9T
3681351
STEP AS
D9T
D9T
3722430
STEP AS
D11T
D11T
3760301
STEP AS
D11T
D11T
3760377
STEP AS
D11T
D11T
3795594
STEP AS
D10T2
D10T2
3796458
STEP AS
D10T2
D10T2
9W0451
STEP
D10N
D10N
9N4897
STEP AS
D4HTSK III
D4HTSK III
9N4898
STEP AS
D4HTSK III
D4HTSK III
8E7156
STEP AS
D5HTSK II
D5HTSK II
8E7155
STEP AS
D5HTSK II
D5HTSK II
8E7152
STEP AS
D5HTSK II
D5HTSK II
8V4744
STEP AS
24H, 834B
24H, 834B
1213025
STEP AS
816F, 816F II
816F, 816F II
2922714
STEP
815F, 815F II
815F, 815F II
1204322
STEP AS
814F, 814F II, 815F, 815F II, 816F, 816F II
814F, 814F II, 815F, 815F II, 816F, 816F II
9W8152
STEP
D9R
D9R
9W8151
STEP
D9R
D9R