9D0565 STEP Caterpillar parts
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA
Rating:
Alternative (cross code) number:
CA9D0565
9D-0565
9D0565
CA9D0565
9D-0565
9D0565
Weight: 2 pounds 1 kg.
MOTOR GRADER,
Compatible equipment models: 9D0565:
Information:
Illustration 1 g01388839
PMPE Generator wiring diagram for the family of 1800 frames
(CR1-C6) Diodes
(CR7) Varistor
(L1) Exciter stator
(L2) Exciter rotor
(L3) Main rotor
(L4) Main stator
(L5) Permanent magnet generator stator
(PM) Permanent magnet
(RFA) Rotating field assembly
(CT1) Optional voltage droop transformer
(T0, T1, T2, T3, T7, T8, T9) Generator terminals
Table 1
Quantity Needed Tool
1 Low ohmmeter Measure the resistance of the following windings: (L1), (L2), (L3), (L4) and (L5). The winding that is being tested must be disconnected from the other components before the resistance can be measured. Note: The winding temperature affects the resistance. When the winding temperature increases, the winding resistance increases. When the winding temperature decreases, the winding resistance decreases. Therefore, a correct measurement can be performed only when the winding is at room temperature.The following resistance measurements are approximations. If the measured value is not near the listed approximation, the winding is probably damaged. For a more precise resistance value, consult the Technical Marketing Information (TMI). Refer to the generator arrangement that is in question.The following windings have very little resistance: (L2), (L4) and (L5). The resistance of these windings will measure near 0 ohms. Use a milliohmmeter to measure the resistance of the windings.Exciter rotor (L2) - Refer to Table 2.Main stator (L4) - less than 0.1 ohmPilot exciter stator (L5) - less than 0.1 ohmUse a multimeter in order to measure the resistance of field windings (L1) and (L3).Exciter field (stator) (L1) - Refer to table 2.Main field (rotor) (L3) - approximately 0.35 ohms to 1.2 ohmsNote: There should be no continuity between any winding and ground. There should be no continuity between any winding and another winding.
Table 2
L1 Exciter Field L2 Exciter Rotor Main Field for the Rotor
1800 Frame 10.9 ohms 0.05 ohms .9 ohms
1600 Frame 10 ohms 0.06 ohms .5 ohms
1400 Frame 11 ohms 0.06 ohms .35 ohms
Cat SIS web machinery list:
Parts step Caterpillar catalog:
8X1030
STEP GP
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
9D1395
STEP GP
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
9D1405
STEP GP
14G
14G
8X1035
STEP GP
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
5R6344
STEP GROUP
130G
130G
4V9809
STEP AS
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
1987379
STEP AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
1250361
STEP AS
16H NA
16H NA
1250359
STEP AS
16H, 16H NA
16H, 16H NA
2803365
STEP AS
D7R II
D7R II
2100779
STEP ASSEM.
D7R II
D7R II
1245181
STEP AS
D7H, D7R, D9N
D7H, D7R, D9N
4E3587
STEP AS-LH
816B
816B
4E3584
STEP AS-RH
816B
816B
9W6033
STEP
D8L, D9N
D8L, D9N
5T7616
STEP AS
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
8W4389
STEP AS
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
2000494
STEP AS
323D L, 323D LN, 325D, 329D L, 330C, 330D, 330D L, 336D L, 336D LN, 336E, 345C L, 345D, 349D L, 365C L, OEMS
323D L, 323D LN, 325D, 329D L, 330C, 330D, 330D L, 336D L, 336D LN, 336E, 345C L, 345D, 349D L, 365C L, OEMS
2C8262
STEP AS-RH
120G, 12G, 130G, 140G
120G, 12G, 130G, 140G
2C8261
STEP AS-LH
120G, 12G, 130G, 140G
120G, 12G, 130G, 140G
1987379
STEP AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA