3876403 STRAINER Caterpillar parts
320D2, 320D2 GC, 320D2 L
Rating:
Alternative (cross code) number:
CA3876403
387-6403
3876403
CA3876403
387-6403
3876403
Weight: 0.01 pounds 0 kg.
EXCAVATOR,
Information:
Probable Causes
Configuration for the communications adapter
Electrical connectors
Communication adapter and/or cables
Electrical power supply to the service tool connector
Electronic service tool and related hardware
Electrical power supply to the Electronic Control Module (ECM)
Data LinkRecommended Actions
Start the engine. If the engine starts, but the ECM will not communicate with the electronic service tool, continue with this procedure. If the engine will not start, refer to Troubleshooting, "Engine Cranks but Will Not Start". If the engine will not crank, refer to Troubleshooting, "Engine Will Not Crank". Configuration for the Communications Adapter
Access "Preferences" under the "Utilities" menu on the electronic service tool.
Verify that the correct "Communications Interface Device" is selected.
Verify that the correct port is selected for use by the communication adapter. Note: The most commonly used port is "COM 1".
Check for any hardware that is utilizing the same port as the communications adapter. If any devices are configured to use the same port, exit or close the software programs for that device. Electrical Connectors
Check for correct installation of the P1/J1 ECM connector and of the diagnostic connector. Refer to Troubleshooting, "Electrical Connectors - Inspect".Communication Adapter and/or Cables
Make sure that the firmware and driver files are the most current files that are available for the type of communication adapter that is being used. If the firmware and driver files do not match, the communication adapter will not communicate with the electronic service tool.
Disconnect the communication adapter and the cables from the diagnostic connector. Reconnect the communication adapter to the diagnostic connector.
Verify that the correct cable is being used between the communication adapter and the diagnostic connector. Refer to Troubleshooting, "Electronic Service Tools".
If the laptop computer is using a Windows operating system, restart the laptop computer in order to eliminate the possibility of a conflict in the software. Electrical Power Supply to the Service Tool Connector
Verify that battery voltage is present between terminals A and B of the diagnostic connector. If the communication adapter is not receiving power, the LED display on the communication adapter will be blank.Electronic Service Tool and Related Hardware
In order to eliminate the electronic service tool and the related hardware as the problem, connect the electronic service tool to a different engine. If the same problem occurs on a different engine, check the electronic service tool and the related hardware in order to determine the cause of the fault.Electrical Power Supply to the Electronic Control Module (ECM)
Check power to the ECM. Refer to Systems Operation, Testing and Adjusting, "Charging System - Test".Note: If the ECM is not receiving battery voltage, the ECM will not communicate.Data Link
Troubleshoot the data link for possible faults. Refer to Troubleshooting, "Data Link Circuit - Test".
Configuration for the communications adapter
Electrical connectors
Communication adapter and/or cables
Electrical power supply to the service tool connector
Electronic service tool and related hardware
Electrical power supply to the Electronic Control Module (ECM)
Data LinkRecommended Actions
Start the engine. If the engine starts, but the ECM will not communicate with the electronic service tool, continue with this procedure. If the engine will not start, refer to Troubleshooting, "Engine Cranks but Will Not Start". If the engine will not crank, refer to Troubleshooting, "Engine Will Not Crank". Configuration for the Communications Adapter
Access "Preferences" under the "Utilities" menu on the electronic service tool.
Verify that the correct "Communications Interface Device" is selected.
Verify that the correct port is selected for use by the communication adapter. Note: The most commonly used port is "COM 1".
Check for any hardware that is utilizing the same port as the communications adapter. If any devices are configured to use the same port, exit or close the software programs for that device. Electrical Connectors
Check for correct installation of the P1/J1 ECM connector and of the diagnostic connector. Refer to Troubleshooting, "Electrical Connectors - Inspect".Communication Adapter and/or Cables
Make sure that the firmware and driver files are the most current files that are available for the type of communication adapter that is being used. If the firmware and driver files do not match, the communication adapter will not communicate with the electronic service tool.
Disconnect the communication adapter and the cables from the diagnostic connector. Reconnect the communication adapter to the diagnostic connector.
Verify that the correct cable is being used between the communication adapter and the diagnostic connector. Refer to Troubleshooting, "Electronic Service Tools".
If the laptop computer is using a Windows operating system, restart the laptop computer in order to eliminate the possibility of a conflict in the software. Electrical Power Supply to the Service Tool Connector
Verify that battery voltage is present between terminals A and B of the diagnostic connector. If the communication adapter is not receiving power, the LED display on the communication adapter will be blank.Electronic Service Tool and Related Hardware
In order to eliminate the electronic service tool and the related hardware as the problem, connect the electronic service tool to a different engine. If the same problem occurs on a different engine, check the electronic service tool and the related hardware in order to determine the cause of the fault.Electrical Power Supply to the Electronic Control Module (ECM)
Check power to the ECM. Refer to Systems Operation, Testing and Adjusting, "Charging System - Test".Note: If the ECM is not receiving battery voltage, the ECM will not communicate.Data Link
Troubleshoot the data link for possible faults. Refer to Troubleshooting, "Data Link Circuit - Test".
Cat SIS web machinery list:
Parts strainer Caterpillar catalog:
3039933
STRAINER AS-FUEL
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN, ...
311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D2 LGP, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN, ...
4516724
STRAINER
320D, 320D L, 320D LN, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323E L, 324D L, 325D L, 329D, 329D L, 330D L, 336D, 336D2, 336E, 336E LN, 349D, 349D L, 349E L VG, 374F L, 390F L
320D, 320D L, 320D LN, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323E L, 324D L, 325D L, 329D, 329D L, 330D L, 336D, 336D2, 336E, 336E LN, 349D, 349D L, 349E L VG, 374F L, 390F L
4516724
STRAINER
320D, 320D L, 320D LN, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323E L, 324D L, 325D L, 329D, 329D L, 330D L, 336D, 336D2, 336E, 336E LN, 349D, 349D L, 349E L VG, 374F L, 390F L
320D, 320D L, 320D LN, 320D2 L, 320E LN, 323D L, 323D LN, 323D SA, 323E L, 324D L, 325D L, 329D, 329D L, 330D L, 336D, 336D2, 336E, 336E LN, 349D, 349D L, 349E L VG, 374F L, 390F L
3655015
STRAINER
320D FM, HH44 DE
320D FM, HH44 DE
3725214
STRAINER
320D FM, HH44 DE, SAT223, SAT318T, SAT322
320D FM, HH44 DE, SAT223, SAT318T, SAT322
2502972
STRAINER
HA770, HA771, HA870, HA871, TK370, TK371, TK380, TK381
HA770, HA771, HA870, HA871, TK370, TK371, TK380, TK381
2041188
STRAINER AS
BA30
BA30
9S5035
STRAINER
D9G, D9H
D9G, D9H
1602045
STRAINER
320B U
320B U
2412295
STRAINER AS
320C FM
320C FM