1461815 STRAP AS Caterpillar parts
302.5C, 3456, 3516C, 420E, 430E, C13, C15, C175-16, C32, CP-44, CP-56, CP-64, CP-76, CS-44, CS-54, CS-64, CS-74, G3512E, G3516C, G3516E, G3520B, G3520C, G3520E, G3606, G3606B, G3608, G3612, G3616, PMG...
Rating:
Alternative (cross code) number:
CA1461815
146-1815
1461815
CA1461815
146-1815
1461815
Weight: 0.05 pounds 0 kg.
Information:
GAGE
10
HOLE SPACING
135
mm
LARGE HOLE DIAMETER
9
mm
SMALL HOLE DIAMETER
9
mm
BACKHOE LOADER, VIBRATORY COMPACTOR,
Compatible equipment models: 1461815:
Information:
OP8 is the option for programming the calibration value of the voltmeter and ammeter. When the GSC or the AC transformer box (ATB) is replaced, the calibration values, written on the ATB bar code sticker, must be programmed into the GSC in order to ensure accurate voltage values and accurate current values. There are five transformers in the ATB that the GSC monitors for information on voltage and current. Each transformer has individual characteristics that affect the voltage and current measurements by the GSC. At the factory, these characteristics are measured, assigned a calibration value and recorded on the bar code sticker which is located on the lower left side of the ATB. When the generator set is assembled at the factory, the calibration values on the bar code sticker are programmed into the GSC. The calibration value of a transformer is from 0 to 255 in increments of 1.The setpoints for the calibration value of the voltmeter and ammeter are in the following list.AC01 - "A-B" Voltage Calibration. The value is selectable from 0 to 255.AC02 - "B-C" Voltage Calibration. The value is selectable from 0 to 255.AC03 - "C-A" Voltage Calibration. The value is selectable from 0 to 255. AC04 - "A" Current Calibration. The value is selectable from 0 to 255.AC05 - "B" Current Calibration. The value is selectable from 0 to 255. AC06 - "C" Current Calibration. The value is selectable from 0 to 255.Procedure For Voltmeter/Ammeter Programming
Note: Service mode cannot be entered when the ECS is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See the Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key seven times. "OP 8" is showing on the lower display.
Press "SELECT" key. "AC01" is showing. The value of the setpoint is also showing. The value will range from 0 to 255.
Press "SELECT" key. The value of the setpoint is flashing.
Press "SCROLL UP" or "SCROLL DOWN" key to adjust the value of the AC01 setpoint to match the value shown on the ATB for "A-B" voltage.
Press "ENTER" key. The value of the setpoint stops flashing.
Press "SCROLL UP" key. Repeat steps 3,
Note: Service mode cannot be entered when the ECS is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP 1" is showing on lower display. See Systems Operation, "Service Mode" for more information. See the Systems Operation, "Password Entry OP3" for more information.
Press "SCROLL UP" key seven times. "OP 8" is showing on the lower display.
Press "SELECT" key. "AC01" is showing. The value of the setpoint is also showing. The value will range from 0 to 255.
Press "SELECT" key. The value of the setpoint is flashing.
Press "SCROLL UP" or "SCROLL DOWN" key to adjust the value of the AC01 setpoint to match the value shown on the ATB for "A-B" voltage.
Press "ENTER" key. The value of the setpoint stops flashing.
Press "SCROLL UP" key. Repeat steps 3,
Cat SIS web machinery list:
Parts strap Caterpillar catalog:
2794738
STRAP-CABLE
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, 428E, ...
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, 428E, ...
2794737
STRAP-CABLE
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, 428E, ...
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, 428E, ...
2794735
STRAP-CABLE
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, ...
303.5C, 303.5D, 303.5E, 303C CR, 303E CR, 304C CR, 304D CR, 304E, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306E, 307D, 307E, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 416E, 416F, 420E, 420F, 422E, 422F, ...
2354644
STRAP AS
TH210, TH215
TH210, TH215
2359059
STRAP
TH210, TH215
TH210, TH215
2186642
STRAP AS
267B
267B
2901993
STRAP-CABLE
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 2384C, 2484C, 24M, 2570C, 2670C, 2864C, 312E, 312E L, 314E CR, 314E LCR, 320E, 320E L, 320E LN, 320E LRR, 320E ...
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 2384C, 2484C, 24M, 2570C, 2670C, 2864C, 312E, 312E L, 314E CR, 314E LCR, 320E, 320E L, 320E LN, 320E LRR, 320E ...
3541224
STRAP AS
312E, 312E L, 314E CR, 314E LCR, 416F, 420F, 428F, 432F, 434F, 444F, D3K2 LGP, D4K2 XL, D5K2 XL
312E, 312E L, 314E CR, 314E LCR, 416F, 420F, 428F, 432F, 434F, 444F, D3K2 LGP, D4K2 XL, D5K2 XL
3895295
STRAP
272D, 272D XHP, 299D, 299D XHP, 910K, 914K
272D, 272D XHP, 299D, 299D XHP, 910K, 914K
3895678
STRAP AS
420F, 428F, 430F, 432F, 434F, 444F, 450F
420F, 428F, 430F, 432F, 434F, 444F, 450F
1343355
STRAP AS
120H, 120M, 120M 2, 12H, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16H, 16M, 24M, 305.5E, 306E, 311F LRR...
120H, 120M, 120M 2, 12H, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 140H, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16H, 16M, 24M, 305.5E, 306E, 311F LRR...
1933973
STRAP-CABLE
1090, 1190, 1190T, 1290T, 1390, 16M, 216B, 226B, 2290, 232B, 2390, 2391, 242B, 247B, 2491, 257B, 2590, 320D, 320D L, 320D LN, 320D LRR, 320D RR, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D2, 33...
1090, 1190, 1190T, 1290T, 1390, 16M, 216B, 226B, 2290, 232B, 2390, 2391, 242B, 247B, 2491, 257B, 2590, 320D, 320D L, 320D LN, 320D LRR, 320D RR, 330D, 330D FM, 330D L, 330D MH, 336D, 336D L, 336D2, 33...