4Z8796 STRAP Caterpillar parts
D8R, D8R II
Rating:
Alternative (cross code) number:
CA4Z8796
4Z-8796
4Z8796
CA4Z8796
4Z-8796
4Z8796
TRACK-TYPE TRACTOR,
Information:
Illustration 1 g01206575
Schematic of the Solenoid Valves (Ride Control)This diagnostic code is associated with ride control solenoid valve #1. The FMI 06 means that the ECM has determined that the current is above normal.The possible causes of this diagnostic code are listed:
The energizer circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. An ECM failure is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2129 - FMI 06 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, the ride control function will stick in a balance position. The other two ride control solenoids are not energized. The operator does not have ride control that is independent of the switch setting.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The FMI 06 changes to FMI 05 after the solenoid is disconnected.Results:
YES - The FMI 06 changes to FMI 05 after the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid has corrected the problem.STOP
NO - The FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
Ride Control Solenoid Valve #1 remains disconnected from the machine harness.
Disconnect the machine harness connectors from the ECM.
At the machine harness connector for the ECM, measure the resistance from J2-5 wire (976-OR) to all contacts that are used in the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
YES - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between the signal circuit for Ride Control Solenoid Valve #1 and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 2129 - FMI 06.Expected Result:The CID 2129 - FMI 06 is active.Results:
YES - The CID 2129 - FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: An ECM failure is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Refer to Testing and
Caterpillar parts catalog:
Parts strap Caterpillar catalog:
4Z8862
STRAP
D9R, D9T
D9R, D9T
6P7106
STRAP
D7G, D8K, D9H
D7G, D8K, D9H
0960091
STRAP
322B, E110B, E120B, E140, E200B, E300
322B, E110B, E120B, E140, E200B, E300
8I2673
STRAP
321B
321B
3X2093
STRAP
325B
325B
7K1171
STRAP
320C FM
320C FM
1081689
STRAP-SUPPORT
D7R, D7R II
D7R, D7R II
4Z9393
STRAP
D7R, D7R II
D7R, D7R II
4Z8891
STRAP-SUPPORT
D7R, D7R II
D7R, D7R II
4Z9407
STRAP
D10R, D10T
D10R, D10T
8E7793
STRAP
D10N, D10R, D11N, D11R, D9N, D9R
D10N, D10R, D11N, D11R, D9N, D9R
8E7792
STRAP
D10N, D10R, D11N, D11R, D9N, D9R
D10N, D10R, D11N, D11R, D9N, D9R