3D2871 STUD-TAPERLOCK Caterpillar parts
120, 120B, 12E, 140, 140B, 14E, 16, 1673, 24H, 3192, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3456, 3512, 3516, 561C, 572G, 589, 621, 623, 623B, 627, 637D, 641, 641B, 650B, 651, 657, 657B, 657E, 666, 7...
Rating:
Alternative (cross code) number:
CA3D2871
3D-2871
3D2871
CA3D2871
3D-2871
3D2871
Weight: 0.04 pounds 0 kg.
Information:
LENGTH
37.5
mm
NUT THREAD LENGTH
0
mm
STUD THREAD LENGTH
0
mm
STUD THREAD SIZE
.38-16
TYPE
FULL LG
ARTICULATED TRUCK, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 3D2871 Stud for Heavy Equipment
CTP Stud Only || Sold in each || Easy in-and-out fit
CTP Stud Only || Sold in each || Easy in-and-out fit
$6.82
24 Mar 2024
Amazon.com
CTP 3D2871 Stud for Heavy Equipment
CTP Stud Only || Sold in each || Easy in-and-out fit
CTP Stud Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 3D2871:
Information:
The purpose of this section is to aid the operator in solving common problems with the M5X communication protocol. This section should only be used for the M5X programming troubleshooting.
Table 1
M5X COMMUNICATION TROUBLESHOOTING    
Problem    Possible Explanation    Action Required    
CCM shows error codes E02 and E08 when receiving data from the PC and will not communicate.     1. There is a protocol error.
2. The data is not in ASCII format.
3. An incorrect checksum was sent.
4. Baud rate of the CCM and PC not matched.     Correct the message being sent to the CCM    
RS-232 receive lights are not lighted, and the CCM will not communicate with the PC even though no error codes are appearing.     Hardware connection between the PC and CCM is corrupted or disconnected.     Using the CCM PC software, connect to the CCM and determine if the connection to the PC is valid.    
Cannot log into the CCM     Connection problem exists or using the wrong M5X protocol for logging in.     Use a read request (PID $F0 $12) to verify that the PC is available to communicate with the CCM. If a valid response is returned, proceed to log in as described in the Logging in section of this manual. If the password has been forgotten, call the CCM Help Desk.    
Cannot get data from the electronic controller.     1. The electronic controller specified is not available.
2. The logged in security level is not high enough to support the request.
3. The electronic controller does not support the PID.     1. Verify that the electronic controller and the CCM are connected on the same data link.
2. Verify that the logged in security level is high enough to support the request.
3. Verify that the electronic controller supports the PID being requested.    
Multiple responses are being generated from a single electronic controller     Multiple electronic controllers have the same MID.     Program the engine number of the electronic controller. Refer to the CCM/Data Link Guidelines section and Programming the Engine Number section in this manual.    
An entire broadcast list is not returned.     1. The electronic controller specified is not available.
2. The electronic controller does not support any one of the PID's.
3. The PID contains greater than two bytes of data.     Refer to the CCM Customized System section, IID 10 and IID 13 in this manual    
A broadcast list update rate is too slow or inconsistent.     1. Too many parameters are being requested.
2. RS-232 baud rate is slow.     1. Verify that the RS-232 and modem baud rates are at least 9600 baud. CCM can not broadcast more than 40 parameters per second. Use IID 13, Byte 7 to slow the update rate for stable parameters such as hour meter, atmospheric pressure, temperature, diagnostics, etc. Use a faster rate for more dynamic parameters such as engine speed, oil pressure, etc. Refer to the RS-232 Communication Protocol for Customized Systems section in this manual for
Table 1
M5X COMMUNICATION TROUBLESHOOTING    
Problem    Possible Explanation    Action Required    
CCM shows error codes E02 and E08 when receiving data from the PC and will not communicate.     1. There is a protocol error.
2. The data is not in ASCII format.
3. An incorrect checksum was sent.
4. Baud rate of the CCM and PC not matched.     Correct the message being sent to the CCM    
RS-232 receive lights are not lighted, and the CCM will not communicate with the PC even though no error codes are appearing.     Hardware connection between the PC and CCM is corrupted or disconnected.     Using the CCM PC software, connect to the CCM and determine if the connection to the PC is valid.    
Cannot log into the CCM     Connection problem exists or using the wrong M5X protocol for logging in.     Use a read request (PID $F0 $12) to verify that the PC is available to communicate with the CCM. If a valid response is returned, proceed to log in as described in the Logging in section of this manual. If the password has been forgotten, call the CCM Help Desk.    
Cannot get data from the electronic controller.     1. The electronic controller specified is not available.
2. The logged in security level is not high enough to support the request.
3. The electronic controller does not support the PID.     1. Verify that the electronic controller and the CCM are connected on the same data link.
2. Verify that the logged in security level is high enough to support the request.
3. Verify that the electronic controller supports the PID being requested.    
Multiple responses are being generated from a single electronic controller     Multiple electronic controllers have the same MID.     Program the engine number of the electronic controller. Refer to the CCM/Data Link Guidelines section and Programming the Engine Number section in this manual.    
An entire broadcast list is not returned.     1. The electronic controller specified is not available.
2. The electronic controller does not support any one of the PID's.
3. The PID contains greater than two bytes of data.     Refer to the CCM Customized System section, IID 10 and IID 13 in this manual    
A broadcast list update rate is too slow or inconsistent.     1. Too many parameters are being requested.
2. RS-232 baud rate is slow.     1. Verify that the RS-232 and modem baud rates are at least 9600 baud. CCM can not broadcast more than 40 parameters per second. Use IID 13, Byte 7 to slow the update rate for stable parameters such as hour meter, atmospheric pressure, temperature, diagnostics, etc. Use a faster rate for more dynamic parameters such as engine speed, oil pressure, etc. Refer to the RS-232 Communication Protocol for Customized Systems section in this manual for
Cat SIS web machinery list:
Parts stud Caterpillar catalog:
4D1315
STUD
666
666
2P1303
STUD
988B, 992
988B, 992
9K7807
STUD
825C, 826C, 834B, 836, 988, 988B, 988F, R2900, R2900G, R3000H
825C, 826C, 834B, 836, 988, 988B, 988F, R2900, R2900G, R3000H
3K1865
STUD
950
950
8X9620
STUD-BALL
789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
789, 789B, 789C, 789D, 793, 793B, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ
8X2560
STUD
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
8X2561
STUD
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
784B, 784C, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D
2269404
STUD
784B, 784C, 785C
784B, 784C, 785C
7D1292
STUD-BALL
772, 772B, 773, 773B, 773D, 775B, 775D, 777, 777B
772, 772B, 773, 773B, 773D, 775B, 775D, 777, 777B
2215305
STUD-BALL
24H, 24M, PM-201, PM-565, PM-565B
24H, 24M, PM-201, PM-565, PM-565B
3D2088
STUD-TAPERLOCK
120B, 120G, 12E, 12G, 130G, 140, 140G, 14G, 160G
120B, 120G, 12E, 12G, 130G, 140, 140G, 14G, 160G
6D4671
STUD-BALL
12G, 130G, 140G, 16, 160G
12G, 130G, 140G, 16, 160G
6V5699
STUD-TAPERLOCK
3408, 3412, 651E, 657E, 773B, 992C, 992D, G3412, PR-750B
3408, 3412, 651E, 657E, 773B, 992C, 992D, G3412, PR-750B
7C7407
STUD
24H, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 5110B, 589, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 84...
24H, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 5110B, 589, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 84...
7M1599
STUD-TAPERLOCK
1140, 1145, 1150, 1160, 3145, 3160, 3408, 3408C, 3412, 3412C, 3412D, 3512, 3512B, 3512C, 3516B, 613, 637D, 651E, 657E, 769C, 773B, 988B, 992C, D343, D8L, G3306, G3408, SPF343C
1140, 1145, 1150, 1160, 3145, 3160, 3408, 3408C, 3412, 3412C, 3412D, 3512, 3512B, 3512C, 3516B, 613, 637D, 651E, 657E, 769C, 773B, 988B, 992C, D343, D8L, G3306, G3408, SPF343C
3K3256
STUD-TAPERLOCK
16G, 16H NA, 245B, 24H, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 583R, 587R, 589, 594, 621B, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 631D, 631E, 6...
16G, 16H NA, 245B, 24H, 3406B, 3406C, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 375, 375 L, 5080, 5110B, 583R, 587R, 589, 594, 621B, 621E, 621F, 623E, 623F, 627B, 627E, 627F, 631D, 631E, 6...
0L0659
STUD
16, 1673C, 1674, 1676, 215, 25, 3304, 3306, 3408, 3408B, 3412, 3412E, 561B, 561C, 561D, 571G, 572G, 583H, 583K, 594, 594H, 621, 621B, 621E, 621R, 623B, 627B, 627E, 637, 650B, 651, 657, 772, 773, 777, ...
16, 1673C, 1674, 1676, 215, 25, 3304, 3306, 3408, 3408B, 3412, 3412E, 561B, 561C, 561D, 571G, 572G, 583H, 583K, 594, 594H, 621, 621B, 621E, 621R, 623B, 627B, 627E, 637, 650B, 651, 657, 772, 773, 777, ...
0L1392
STUD
129, 1673C, 24, 3304, 3306, 3408, 3412, 41, 651, 657, 941, 951B, 992, D348, D353C, D4D, D4E, D4E SR, G3408, G3412
129, 1673C, 24, 3304, 3306, 3408, 3412, 41, 651, 657, 941, 951B, 992, D348, D353C, D4D, D4E, D4E SR, G3408, G3412
9M5082
STUD-TAPERLOCK
3208, 3408, 3412, 3508, 3508C, 3512, 3516, 768B, 769, 769C, 772, 773, 773B, D6D, D6G, D6G2 LGP, D6G2 XL, PR-1000, PS-500
3208, 3408, 3412, 3508, 3508C, 3512, 3516, 768B, 769, 769C, 772, 773, 773B, D6D, D6G, D6G2 LGP, D6G2 XL, PR-1000, PS-500
1345573
STUD
3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, G3408, G3408B, G3412
3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, G3408, G3408B, G3412
9S1398
STUD
130G, 14G, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B, 777, G3408, G3408B, G3412, G399
130G, 14G, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508B, 3512, 3512B, 3516, 3516B, 777, G3408, G3408B, G3412, G399
5L1719
STUD-TAPERLOCK
235B, 3412, 3412C, 3412D, 3412E, 572R, 651E, 657E, 992C, C30, C32, D7G, D7G2, D7R, D9L
235B, 3412, 3412C, 3412D, 3412E, 572R, 651E, 657E, 992C, C30, C32, D7G, D7G2, D7R, D9L
8M1047
STUD-TAPERLOCK
120G, 12E, 12G, 130G, 1673, 245B, 3406B, 3408, 3408B, 3412, 3412D, 3412E, 374F L, 390F L, 561B, 57, 578, 58, 594H, 621G, 623B, 623E, 623G, 627B, 627G, 633D, 641B, 650B, 651E, 657E, 657G, 69D, 735B, 74...
120G, 12E, 12G, 130G, 1673, 245B, 3406B, 3408, 3408B, 3412, 3412D, 3412E, 374F L, 390F L, 561B, 57, 578, 58, 594H, 621G, 623B, 623E, 623G, 627B, 627G, 633D, 641B, 650B, 651E, 657E, 657G, 69D, 735B, 74...
8T5409
STUD-TAPERLOCK
3116, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 773F, 775F, 785C, 785D, C15, C18, C27, C32, G3306, G3306B, G3406, G3408, G3408B, G3412, PM-200,...
3116, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 773F, 775F, 785C, 785D, C15, C18, C27, C32, G3306, G3306B, G3406, G3408, G3408B, G3412, PM-200,...