1365644 SUPPORT-END Caterpillar parts
834K
Rating:
Alternative (cross code) number:
CA1365644
136-5644
1365644
CA1365644
136-5644
1365644
Weight: 86 pounds 39 kg.
WHEEL DOZER,
Compatible equipment models: 1365644:
Information:
Illustration 1 g01507889
(1) Compressor
(2) Condenser
(3) In-line dryer
(4) Desiccant
(5) Orifice Tube
(6) Evaporator
(7) Accumulator
(A) High temperature high pressure refrigerant vapor
(B) High temperature, high pressure refrigerant liquid
(C) Low temperature, low pressure refrigerant liquid vapor mixture
(D) Low temperature low pressure refrigerant vapor The air conditioner refrigerant begins to flow in the air conditioning system at refrigerant compressor (1). The compressor is designed to change the air conditioner refrigerant from a vapor that has low pressure into a vapor that has high pressure. Also, the compressor changes the refrigerant from a vapor with low temperature to a vapor with high temperature. The increase in pressure causes the increase in temperature.The refrigerant is sent through condenser coil (2). In the condenser coil, heat is transferred from the refrigerant to the outside air. This changes the refrigerant to a high temperature and high pressure liquid.From condenser coil (2), the refrigerant moves to in-line dryer (3). In in-line dryer (3), moisture is removed from the refrigerant by desiccant (4). Some orifice tube systems will not contain an in-line dryer. In this case, the desiccant is located in accumulator (7).Next, the refrigerant flows to the orifice tube. When the refrigerant is at the orifice tube, the refrigerant is changed from a high pressure and high temperature liquid to a liquid vapor mixture that is low pressure and low temperature.The low pressure and low temperature refrigerant moves to evaporator coil (6). While the refrigerant is in the evaporator coil the refrigerant absorbs heat from the cab. This changes the refrigerant to a low pressure and low temperature vapor.After the evaporator coil, the refrigerant flows to the accumulator. The accumulator stores liquid refrigerant that is exiting the evaporator and the accumulator allows only vapor to continue to the compressor.The low pressure and low temperature vapor returns to the compressor. This marks the end of the cycle. The cycle is repeated continuously.
Caterpillar parts catalog:
Parts support Caterpillar catalog:
3659091
SUPPORT AS
824K, 825K, 826K, 834K, 836K, 988K
824K, 825K, 826K, 834K, 836K, 988K
3739947
SUPPORT AS
824K, 825K, 826K, 834K, 836K, 988K
824K, 825K, 826K, 834K, 836K, 988K
3688216
SUPPORT AS
824K, 825K, 826K, 834K, 836K, 988K
824K, 825K, 826K, 834K, 836K, 988K
1332202
SUPPORT AS-TRUNNION
834G, 834H, 834K
834G, 834H, 834K
2086035
SUPPORT AS
824G II, 824H, 824K, 825G II, 825H, 825K, 826G II, 826H, 826K, 834G, 834H, 834K, 836G, 836H, 836K
824G II, 824H, 824K, 825G II, 825H, 825K, 826G II, 826H, 826K, 834G, 834H, 834K, 836G, 836H, 836K
2086036
SUPPORT AS
824G II, 824H, 824K, 825G II, 825H, 825K, 826G II, 826H, 826K, 834G, 834H, 834K, 836G, 836H, 836K
824G II, 824H, 824K, 825G II, 825H, 825K, 826G II, 826H, 826K, 834G, 834H, 834K, 836G, 836H, 836K
3332023
SUPPORT AS
834H, 834K
834H, 834K
3332026
SUPPORT AS
834H, 834K
834H, 834K
3729082
SUPPORT AS
834K
834K
3784680
SUPPORT AS
834K
834K
1326259
SUPPORT-EDGE
834K
834K
3784680
SUPPORT AS
834K
834K
3729082
SUPPORT AS
834K
834K
3459832
SUPPORT AS
854K
854K
3641874
SUPPORT
D11R
D11R
3641873
SUPPORT
D11R
D11R
2507012
SUPPORT
14M, 16M, D8N
14M, 16M, D8N
3719459
SUPPORT AS
836K
836K
3719457
SUPPORT AS
836K
836K
3657897
SUPPORT AS
836K
836K
3657896
SUPPORT AS
836K
836K
1326259
SUPPORT-EDGE
834K
834K