Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Check for Diagnostic Codes that are Active
A. Establish communication between Cat® ET and the Electronic Control Module (ECM). Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check and record any event codes that are active or logged.
   
Diagnostic Code
   
Result: A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 diagnostic code is present, proceed to Test Step 2.
Result: A E993 (3) or 3703-31 diagnostic code is present, proceed to Test Step 3.
Result: A E1040 (2) or 3530-31 diagnostic code is present, proceed to Test Step 4.
Result: An E1300 (1), E1300 (2), 3716-15 or 3716-31 diagnostic code is present, proceed to Test Step 5.
Result: A E1301 (1) or 3712-15 diagnostic code is present, proceed to Test Step 6.
Result: A E1302 (1) or 3750-15 diagnostic code is present, proceed to Test Step 7.
Result: A E1305 (1) or 3483-11 diagnostic code is present, proceed to Test Step 8.
   
2. A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 Diagnostic Code is Present.
A. The operator did not allow a regeneration to occur or an automatic regeneration did not occur within the required time limit. The operator must respond when the DPF lamp is illuminated.
B. Perform a "Forced Regeneration" by pressing the "Regeneration Force Switch" button.
   
Forced Regeneration
   
Result: The "Forced Regeneration" was successful.
Return the unit to service.
Result: The "Forced Regeneration" was not successful.
Repair: Troubleshoot the active diagnostic codes.
   
3. A E993 (3) or 3703-31 Diagnostic Code is Present.
A. The operator has disabled the regeneration system and a regeneration is necessary.
   
Disabled Regeneration
   
Result: Perform a regeneration. Refer to the Operation and Maintenance Manual, "Diesel Particulate Filter Regeneration" for the proper operation of the regeneration system.
Return the unit to service.
   
4. A E1040 (2) or 3530-31 Diagnostic Code is Present.
A. The regeneration system is disabled by Cat ET.
   
Regeneration Disabled by Cat ET.
   
Result: Establish communication between Cat ET and the engine ECM. Set the value of the "Aftertreatment Regeneration Device" from "Disabled" to "Enabled".
Return the unit to service.
   
5. Aftertreatment Regeneration Cannot Start Due To Low Engine Temperature
A. The engine temperature is too low for an aftertreatment regeneration.
   
Low Engine Temperature
   
Result: Raise the coolant temperature above
40° C (104° F ) and the Diesel Particulate Filter inlet temperature above
50° C (122° F). If the ambient temperature is
-15° C (5° F) or below, the coolant temperature must be above
60° C (140° F) for an active regeneration to begin.
Return the unit to service.
   
6. Aftertreatment Regeneration Cannot Start Due to System Fault
A. Establish communication between the Caterpillar Electronic Technician (ET) and the engine Electronic Control Module (ECM).
B. Check for active faults related to the ARD combustion air system, ARD fuel system,
Table 2
Troubleshooting Test Steps    Values    Results    
1. Check for Diagnostic Codes that are Active
A. Establish communication between Cat® ET and the Electronic Control Module (ECM). Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check and record any event codes that are active or logged.
   
Diagnostic Code
   
Result: A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 diagnostic code is present, proceed to Test Step 2.
Result: A E993 (3) or 3703-31 diagnostic code is present, proceed to Test Step 3.
Result: A E1040 (2) or 3530-31 diagnostic code is present, proceed to Test Step 4.
Result: An E1300 (1), E1300 (2), 3716-15 or 3716-31 diagnostic code is present, proceed to Test Step 5.
Result: A E1301 (1) or 3712-15 diagnostic code is present, proceed to Test Step 6.
Result: A E1302 (1) or 3750-15 diagnostic code is present, proceed to Test Step 7.
Result: A E1305 (1) or 3483-11 diagnostic code is present, proceed to Test Step 8.
   
2. A E1239 (1), E1239 (2), E1239 (3), 3750-31, 3750-17 or 3750-18 Diagnostic Code is Present.
A. The operator did not allow a regeneration to occur or an automatic regeneration did not occur within the required time limit. The operator must respond when the DPF lamp is illuminated.
B. Perform a "Forced Regeneration" by pressing the "Regeneration Force Switch" button.
   
Forced Regeneration
   
Result: The "Forced Regeneration" was successful.
Return the unit to service.
Result: The "Forced Regeneration" was not successful.
Repair: Troubleshoot the active diagnostic codes.
   
3. A E993 (3) or 3703-31 Diagnostic Code is Present.
A. The operator has disabled the regeneration system and a regeneration is necessary.
   
Disabled Regeneration
   
Result: Perform a regeneration. Refer to the Operation and Maintenance Manual, "Diesel Particulate Filter Regeneration" for the proper operation of the regeneration system.
Return the unit to service.
   
4. A E1040 (2) or 3530-31 Diagnostic Code is Present.
A. The regeneration system is disabled by Cat ET.
   
Regeneration Disabled by Cat ET.
   
Result: Establish communication between Cat ET and the engine ECM. Set the value of the "Aftertreatment Regeneration Device" from "Disabled" to "Enabled".
Return the unit to service.
   
5. Aftertreatment Regeneration Cannot Start Due To Low Engine Temperature
A. The engine temperature is too low for an aftertreatment regeneration.
   
Low Engine Temperature
   
Result: Raise the coolant temperature above
40° C (104° F ) and the Diesel Particulate Filter inlet temperature above
50° C (122° F). If the ambient temperature is
-15° C (5° F) or below, the coolant temperature must be above
60° C (140° F) for an active regeneration to begin.
Return the unit to service.
   
6. Aftertreatment Regeneration Cannot Start Due to System Fault
A. Establish communication between the Caterpillar Electronic Technician (ET) and the engine Electronic Control Module (ECM).
B. Check for active faults related to the ARD combustion air system, ARD fuel system,
Caterpillar parts catalog:
Parts support Caterpillar catalog:
1116281
SUPPORT GP-SEAT
307B, 311B, 312B, 312B L, 315B, 315B FM L, 315B L, 317B LN, 318B, 320B, 320B FM LL, 320B L, 320B U, 322B, 322B L, 322B LN, 325B, 325B L, 330B, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II,...
307B, 311B, 312B, 312B L, 315B, 315B FM L, 315B L, 317B LN, 318B, 320B, 320B FM LL, 320B L, 320B U, 322B, 322B L, 322B LN, 325B, 325B L, 330B, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II,...
0855738
SUPPORT AS
311, 311B, 311C, 312, 312B, 312B L, 313B, E110B, E120B
311, 311B, 311C, 312, 312B, 312B L, 313B, E110B, E120B
6I6456
SUPPORT
311, 311B, 312, 312B, 312B L, 313B
311, 311B, 312, 312B, 312B L, 313B
5I8760
SUPPORT
308E, 308E CR, 308E SR, 311, 311B, 312, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317, 317B LN, 318B
308E, 308E CR, 308E SR, 311, 311B, 312, 312B, 312B L, 315, 315B, 315B FM L, 315B L, 317, 317B LN, 318B
6C8795
SUPPORT AS
307, 312, 312B L, 315, 315B L, 317, 317B LN, 318B, 320 L, 320B, 322B LN, 325 L, 325B L, 330B L, 345B II, 345B L, 350, 365B, 365B II, 375, 385B, 5090B
307, 312, 312B L, 315, 315B L, 317, 317B LN, 318B, 320 L, 320B, 322B LN, 325 L, 325B L, 330B L, 345B II, 345B L, 350, 365B, 365B II, 375, 385B, 5090B
1225500
SUPPORT AS
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 314C, 314D CR, 314D LCR, 315C, 315D L, 320C, 321C
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 312E, 312E L, 313B, 314C, 314D CR, 314D LCR, 315C, 315D L, 320C, 321C
1576381
SUPPORT
312B L
312B L
1229622
SUPPORT
307B, 308C, 311B, 312B L, 314C, 315B L, 317B LN, 318B, 320B, 320B FM LL, 320B L, 321B, 321C, 322B L, 322B LN, 325B, 325B L, 325C, 330B, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L...
307B, 308C, 311B, 312B L, 314C, 315B L, 317B LN, 318B, 320B, 320B FM LL, 320B L, 321B, 321C, 322B L, 322B LN, 325B, 325B L, 325C, 330B, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L...
1276794
SUPPORT AS
307B, 311B, 312B, 312B L, 315B L, 317B LN, 318B, 320B, 320B L, 322B LN, 322C, 325B, 325B L, 330B L, 345B II, 345B L, 375
307B, 311B, 312B, 312B L, 315B L, 317B LN, 318B, 320B, 320B L, 322B LN, 322C, 325B, 325B L, 330B L, 345B II, 345B L, 375
1351578
SUPPORT AS
312B L
312B L
1218961
SUPPORT AS
311B, 312B, 312B L
311B, 312B, 312B L
1506546
SUPPORT AS
312B L
312B L
1391613
SUPPORT AS
312B L
312B L
1729276
SUPPORT
312B L
312B L
1448808
SUPPORT AS
312B L, 315B L, 317B LN, 318B
312B L, 315B L, 317B LN, 318B
1737604
SUPPORT
312B L
312B L
1176270
SUPPORT AS
307B, 308C, 311B, 312B L, 314C, 315B L, 317B LN, 318B, 320B, 321C, 322B L, 322B LN, 325B, 325B L, 325C, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 385B, 5090B, 5110B, 539, M325B...
307B, 308C, 311B, 312B L, 314C, 315B L, 317B LN, 318B, 320B, 321C, 322B L, 322B LN, 325B, 325B L, 325C, 330B L, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 385B, 5090B, 5110B, 539, M325B...
2356666
SUPPORT
312B L
312B L
1351574
SUPPORT AS
312B L
312B L
1218957
SUPPORT AS
311B, 312B, 312B L
311B, 312B, 312B L
7I1418
SUPPORT AS
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 315B, 315B L, 315C, 317B LN, 318B, 318C, 319C, 320, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320D LN, 320D LRR, 320D RR, 322B, 322B L, 322B LN,...
311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 315B, 315B L, 315C, 317B LN, 318B, 318C, 319C, 320, 320 L, 320B, 320B FM LL, 320B U, 320C, 320C FM, 320D LN, 320D LRR, 320D RR, 322B, 322B L, 322B LN,...