3N4565 SUPPORT-PANEL Caterpillar parts
3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508C, 3512, 3516, 3516B, C-15, C-16, C15, C18, C27, C30, C32, CX31-C15I, CX35-P800, D348, G3508, G3512, G3516, TH...
Rating:
Alternative (cross code) number:
CA3N4565
3N-4565
3N4565
CA3N4565
3N-4565
3N4565
Weight: 1 pounds 0 kg.
GAS ENGINE, PETROLEUM TRANSMISSION,
Compatible equipment models: 3N4565:
Information:
OP5-0 is the option for programming the engine/generator setpoints. The engine/generator setpoints affect the proper operation and serviceability of the engine, and the accuracy of information shown on the display. The setpoints are programmed in the GSC+ at the factory.The setpoints may require changing when the GSC+ is moved from one engine to another engine. The setpoints may also require changing in order to satisfy the customer's requirements. The setpoints that are stored in the GSC+ must match the specified setpoints of the particular generator set. The setpoints are P001 to P033 and the setpoints are programmable. The setpoints are described in the OP5-0 Setpoints. Refer to Table 1.Procedure For Engine/Generator Programming
Note: Service Mode cannot be entered when the engine control switch (ECS) is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. When a shutdown fault is active, a shutdown indicator is FLASHING. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must be no longer occurring. The fault must be corrected and the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in the OFF/RESET position and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP4" is showing on the lower display. For more information, see Systems Operation, "Password Entry OP3".
Press "SCROLL UP" key again. "OP5-0" is showing on the lower display.
Press "SELECT" key again. "P001" is showing on the display. "P001" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the value of the setpoint. Repeat this step until the desired setpoint is showing.
Press the "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" key or press the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: Press and hold the appropriate "SCROLL" key in order to rapidly scroll through a large range of values.
Press the "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6, and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display will return to the normal mode.
Table 1
OP5-0 Setpoints - Engine/Generator Programming (1)    
Setpoint    Name    Description    Range Of Value    Factory Default    
P001     Fuel Solenoid Type     Type of fuel system solenoid used on the generator set. All Larne-built generators covered by this manual are ALWAYS programmed as ETR (0), even if the generator has an ETS fuel solenoid.     0 -
Note: Service Mode cannot be entered when the engine control switch (ECS) is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. When a shutdown fault is active, a shutdown indicator is FLASHING. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the shutdown fault must be no longer occurring. The fault must be corrected and the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, the GSC+ does not power up in the OFF/RESET position and any active shutdown fault must be corrected before entering service mode.
Turn the ECS to the STOP position in order to shut down the engine. Enter service mode and enter the password. "OP4" is showing on the lower display. For more information, see Systems Operation, "Password Entry OP3".
Press "SCROLL UP" key again. "OP5-0" is showing on the lower display.
Press "SELECT" key again. "P001" is showing on the display. "P001" is followed by the value of the setpoint.
Press the "SCROLL UP" key or the "SCROLL DOWN" key. The next setpoint is showing with the value of the setpoint. Repeat this step until the desired setpoint is showing.
Press the "SELECT" key. The value of the setpoint is flashing.
Press the "SCROLL UP" key or press the "SCROLL DOWN" key in order to adjust the value of the setpoint.Note: Press and hold the appropriate "SCROLL" key in order to rapidly scroll through a large range of values.
Press the "ENTER" key. The value of the setpoint stops flashing. Repeat steps 4, 5, 6, and 7 until all the desired setpoints are adjusted.
Press "EXIT" key. "OP 1" is showing on the lower display.
Press "EXIT" key. The display will return to the normal mode.
Table 1
OP5-0 Setpoints - Engine/Generator Programming (1)    
Setpoint    Name    Description    Range Of Value    Factory Default    
P001     Fuel Solenoid Type     Type of fuel system solenoid used on the generator set. All Larne-built generators covered by this manual are ALWAYS programmed as ETR (0), even if the generator has an ETS fuel solenoid.     0 -
Cat SIS web machinery list:
Parts support Caterpillar catalog:
6N6732
SUPPORT-HOUSING
3408, 3408B, 3408C, 589, 631E, 637D, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, G3408, G3408B, G3408C, PM-565, PR-450, PR-450C
3408, 3408B, 3408C, 589, 631E, 637D, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, G3408, G3408B, G3408C, PM-565, PR-450, PR-450C
4N1010
SUPPORT-ELBOW
245, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 992C, C-15, C-16, HT400, PM-465, PM3412, PM3456, RM-250C, RR-250, RR-250B, SS-250
245, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 992C, C-15, C-16, HT400, PM-465, PM3412, PM3456, RM-250C, RR-250, RR-250B, SS-250
8N2002
SUPPORT
3516
3516
7N8648
SUPPORT AS
3508
3508
7N8647
SUPPORT AS
3508
3508
7N8644
SUPPORT AS
3508, 3508B, 3508C, G3508, G3508B
3508, 3508B, 3508C, G3508, G3508B
7N8643
SUPPORT AS
3508, 3508B, 3508C, G3508, G3508B
3508, 3508B, 3508C, G3508, G3508B
1W1276
SUPPORT AS
3508
3508
1W1275
SUPPORT AS
3508
3508
7W1363
SUPPORT-ENGINE
3512, 3516
3512, 3516
4W8697
SUPPORT-ENGINE
3512, 3516
3512, 3516
2W3406
SUPPORT-SWITCH
3508, 3512, 3512B, 3516, 3516B, 3516C, G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B, PMG3516
3508, 3512, 3512B, 3516, 3516B, 3516C, G3508, G3508B, G3512, G3512B, G3516, G3516B, G3520B, PMG3516
1W8133
SUPPORT
3508, 3508C, 3512, 3512B, 3516, 3516B, G3508, G3512, G3516
3508, 3508C, 3512, 3512B, 3516, 3516B, G3508, G3512, G3516
2W8811
SUPPORT
3508, 3508C, 3512, 3516, 3516B
3508, 3508C, 3512, 3516, 3516B
5N2195
SUPPORT-PANEL
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608