6N7249 SUPPORT-SUCTION BELL Caterpillar parts
16G, 3406, 3406B, 3406C, 3406E, 3456, 621, 621B, 623B, 627B, 631D, 637D, 657B, 657E, 657G, 735, 740, 980C, 980F, C-15, C-16, C15, C18, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3406, HT400, PM-465,...
Rating:
Alternative (cross code) number:
CA6N7249
6N-7249
6N7249
CA6N7249
6N-7249
6N7249
Weight: 1 pounds 0 kg.
ARTICULATED TRUCK, WHEEL TRACTOR,
Compatible equipment models: 6N7249:
Information:
Conditions Which Generate This Code:
Illustration 1 g00721914
System Schematic For The Programmable Spare Relay ("PSR1" & "PSR2").The GSC+ uses the programmable spare relay (PSR) in order to activate the customer equipment. See Systems Operation, "Spare Input/Output Programming OP6".Note: Whenever the GSC+ activates or the GSC+ attempts to activate the PSR, K8 is shown on the lower display. When the PSR is not activated, K8 is not shown.The possible cause of a CID 0448 FMI 12 is an open coil or a shorted coil of the PSR.The system responses to these diagnostic codes are listed below.
If a CID 0448 FMI 12 occurs and the PSR is active, any customer equipment on RM-25 (normally open) will be deactivated. Any customer equipment on RM-26 (normally closed) will remain activated.
If a CID 0448 FMI 12 occurs while the PSR is inactive, any customer equipment on RM-25 (normally open output) will remain deactivated and any customer equipment on RM-26 (normally closed) will remain activated.The GSC+ treats a CID 0448 FMI 12 as an alarm fault. Active alarm faults are shown on the display when the "Alarm Codes" key is pressed and the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.This troubleshooting procedure is for an active CID 0448 or the troubleshooting procedure is for an inactive CID 448 FMI 12.Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "Alarm Codes" key.
Observe the upper display. Check that the CID 0448 FMI 12 is active.
If the diagnostic code is not active, enter the Service Mode. View the fault log for a OP1. Check that the diagnostic code is inactive.Expected Result:A CID 0448 FMI 12 is displayed as an active diagnostic code or CID 0448 FMI 12 is displayed as an inactive diagnostic code.Results:
OK - The CID 0448 FMI 12 is active or the CID 0448 FMI 12 is inactive. Proceed to test step 2.
NOT OK - The CID 0448 FMI 12 has not occurred. The diagnostic code is not active and the diagnostic code is not inactive.STOPTest Step 2. CHECK THE INTERNAL CABLE OF THE RELAY MODULE.Note: Only open the relay module in a dry environment. If the inspection and repair takes more than approximately twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to the OFF/RESET position.
Disconnect the battery negative cable.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+.Expected Result:The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged.Results:
OK - The cable is firmly seated in the connector. The clamp is in place. The cable is not damaged. Reassemble the relay module to the GSC+. Proceed to test step 3.
NOT OK - One or more of the
Illustration 1 g00721914
System Schematic For The Programmable Spare Relay ("PSR1" & "PSR2").The GSC+ uses the programmable spare relay (PSR) in order to activate the customer equipment. See Systems Operation, "Spare Input/Output Programming OP6".Note: Whenever the GSC+ activates or the GSC+ attempts to activate the PSR, K8 is shown on the lower display. When the PSR is not activated, K8 is not shown.The possible cause of a CID 0448 FMI 12 is an open coil or a shorted coil of the PSR.The system responses to these diagnostic codes are listed below.
If a CID 0448 FMI 12 occurs and the PSR is active, any customer equipment on RM-25 (normally open) will be deactivated. Any customer equipment on RM-26 (normally closed) will remain activated.
If a CID 0448 FMI 12 occurs while the PSR is inactive, any customer equipment on RM-25 (normally open output) will remain deactivated and any customer equipment on RM-26 (normally closed) will remain activated.The GSC+ treats a CID 0448 FMI 12 as an alarm fault. Active alarm faults are shown on the display when the "Alarm Codes" key is pressed and the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.This troubleshooting procedure is for an active CID 0448 or the troubleshooting procedure is for an inactive CID 448 FMI 12.Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "Alarm Codes" key.
Observe the upper display. Check that the CID 0448 FMI 12 is active.
If the diagnostic code is not active, enter the Service Mode. View the fault log for a OP1. Check that the diagnostic code is inactive.Expected Result:A CID 0448 FMI 12 is displayed as an active diagnostic code or CID 0448 FMI 12 is displayed as an inactive diagnostic code.Results:
OK - The CID 0448 FMI 12 is active or the CID 0448 FMI 12 is inactive. Proceed to test step 2.
NOT OK - The CID 0448 FMI 12 has not occurred. The diagnostic code is not active and the diagnostic code is not inactive.STOPTest Step 2. CHECK THE INTERNAL CABLE OF THE RELAY MODULE.Note: Only open the relay module in a dry environment. If the inspection and repair takes more than approximately twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to the OFF/RESET position.
Disconnect the battery negative cable.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+.Expected Result:The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged.Results:
OK - The cable is firmly seated in the connector. The clamp is in place. The cable is not damaged. Reassemble the relay module to the GSC+. Proceed to test step 3.
NOT OK - One or more of the
Cat SIS web machinery list:
Parts support Caterpillar catalog:
6N6732
SUPPORT-HOUSING
3408, 3408B, 3408C, 589, 631E, 637D, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, G3408, G3408B, G3408C, PM-565, PR-450, PR-450C
3408, 3408B, 3408C, 589, 631E, 637D, 637E, 657E, 768C, 769C, 771C, 834B, 988B, 988F, D8L, D9N, D9R, G3408, G3408B, G3408C, PM-565, PR-450, PR-450C
4N1010
SUPPORT-ELBOW
245, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 992C, C-15, C-16, HT400, PM-465, PM3412, PM3456, RM-250C, RR-250, RR-250B, SS-250
245, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 992C, C-15, C-16, HT400, PM-465, PM3412, PM3456, RM-250C, RR-250, RR-250B, SS-250
8X1032
SUPPORT-STEP
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 561...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 561...
1T1348
SUPPORT AS-CARRIAGE
621, 621B, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631E, 631G, 633E II, 637D, 637E, 637G, 657B, 657E, 657G
621, 621B, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631E, 631G, 633E II, 637D, 637E, 637G, 657B, 657E, 657G
6N9743
SUPPORT-MUFFLER
623F, 824C, 826C, 980C, 980F
623F, 824C, 826C, 980C, 980F
7N6381
SUPPORT
824C, 826C, 980C, 980F
824C, 826C, 980C, 980F
5K4305
SUPPORT AS
824C, 980, 980B, 980C, 980F, R1700 II
824C, 980, 980B, 980C, 980F, R1700 II
9V7860
SUPPORT AS-FRONT
980C, R1700 II
980C, R1700 II
3P2769
SUPPORT AS
14G, 16G
14G, 16G
3510913
SUPPORT
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3456, C-15, C-16, C13, C15, C18, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3406, HT400, PM3456, TH35-C15I
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3456, C-15, C-16, C13, C15, C18, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3406, HT400, PM3456, TH35-C15I
4W5074
SUPPORT-REAR
3176B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C15, C18, C27, C32, CG137-08, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3406, G3408, G3408B, G3408C, G341...
3176B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C15, C18, C27, C32, CG137-08, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3406, G3408, G3408B, G3408C, G341...
6N0500
SUPPORT AS-FRONT
3406, 3406B, 3406C, 3408, 3408C
3406, 3406B, 3406C, 3408, 3408C
9Y5904
SUPPORT AS
3304B, 3306, 3306B
3304B, 3306, 3306B
8N3236
SUPPORT AS-RACK
3304, 3304B, 3306, 3306B
3304, 3304B, 3306, 3306B
1975514
SUPPORT AS
3508, 3508B, 3508C, G3508, G3516, PM3508
3508, 3508B, 3508C, G3508, G3516, PM3508
4W0661
SUPPORT-RADIATOR-LH
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406
4W0662
SUPPORT-RADIATOR-RH
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406
4W0663
SUPPORT-RADIATOR
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406
4W0660
SUPPORT-RADIATOR
3406, 3406B, 3406C, G3406
3406, 3406B, 3406C, G3406
5N4487
SUPPORT AS
3406, 3406B, 3406C, 3408, 3412, G3406
3406, 3406B, 3406C, 3408, 3412, G3406
5N4656
SUPPORT AS
3406, 3406B, 3406C, 3408, 3412, G3406
3406, 3406B, 3406C, 3408, 3412, G3406