Information:
Illustration 1 g01365346
Schematic of the R Conveyor Rev Pump SolenoidThis diagnostic code is associated with the R Conveyor Rev Pump Solenoid. The FMI 05 means that the RH Operator ECM has detected that the current for the solenoid circuit is below normal.Note: The RH Operator ECM is located under the RH Operator platform.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. System Response:When this diagnostic code is active, the following occurs:
Right conveyor reverse is disabled.
Operator station fault lamp is active.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).Test Step 1. CHECK THE SOLENOID
Disconnect the machine harness from the solenoid at the R Conveyor Rev Pump hydraulic valve.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire A971-BU) to contact 2 (H863-BU).
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the CID 2550 FMI 05 diagnostic code.Expected Result:The CID 2550 FMI 05 diagnostic code is no longer active. A CID 2550 FMI 06 diagnostic code becomes active when the jumper wire is connected.Results:
YES - The CID 2550 FMI 05 diagnostic code is no longer active. A CID 2550 FMI 06 diagnostic code becomes active when the jumper wire is connected. The solenoid has failed.Repair: Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F). Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The CID 2550 FMI 05 diagnostic code remains active. The jumper wire does not affect the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE CIRCUIT FOR AN OPENThe jumper wire that was installed in the previous Test Step remains in place.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness ECM connector J1 from the ECM.
At the machine harness connector J1 for the ECM, measure the resistance from contact J1-49 (wire A971-BU) to J1-50 (H863-BU).
While observing the multimeter resistance measurement, wiggle the machine harness connectors for the ECM and wiggle the machine harness connector for the solenoid. Gently
Caterpillar parts catalog:
Parts support Caterpillar catalog:
2P3882
SUPPORT ASSEMBLY
824B, 825B, 834, 988
824B, 825B, 834, 988
6M1561
SUPPORT
824, 824B, 834, 988, 992
824, 824B, 834, 988, 992
1S9987
SUPPORT
824, 824B, 988
824, 824B, 988
8M2259
SUPPORT ASSEM.
824B, 988
824B, 988
7K4343
SUPPORT
824B, 825B, 826B, 834, 988, 992
824B, 825B, 826B, 834, 988, 992
1S4869
SUPPORT ASSEM.
824B, 988
824B, 988
7K3100
SUPPORT ASSEM.
824B, 826B, 988, 992
824B, 826B, 988, 992
9K0364
SUPPORT ASSEM.
824B, 988
824B, 988
9K0364
SUPPORT ASSEM.
824B, 988
824B, 988
6K1762
SUPPORT
980, 980B
980, 980B
7K8461
SUPPORT ASSEM.
814, 816, 950, 966C
814, 816, 950, 966C
9K5555
SUPPORT ASSEM.
814, 815, 816, 966C
814, 815, 816, 966C
6K6474
SUPPORT ASSEM.
814, 815, 966C
814, 815, 966C
7K0904
SUPPORT ASSEM
814, 815, 816, 966C, 966R
814, 815, 816, 966C, 966R
8J4975
SUPPORT
992
992