1635673 SWITCH AS- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1635673
163-5673
1635673
CA1635673
163-5673
1635673
Weight: 0.94 pounds 0 kg.
Information:
Table 1
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
4212-5 291-5 Engine Cooling Fan Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
4212-6 291-6 Engine Cooling Fan Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
N/A 1076-5 Engine Cooling Fan Bypass Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
N/A 1076-6 Engine Cooling Fan Bypass Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan bypass solenoid. The code is logged. The ECM monitors engine coolant temperature, intake manifold air temperature, and hydraulic oil temperature. The ECM monitors the sensors in order to determine the correct speed for the engine cooling fan.The ECM controls the speed of the fan by controlling the current to the engine fan control solenoid. The engine fan control solenoid controls the amount of pressure to the fan pump by allowing oil to bypass the fan pump. The fan pump drives the fan. When the ECM outputs minimum current to the engine fan control solenoid, less oil is bypassed. The fan pump will now drive the fan at a higher rpm. When the ECM outputs maximum current to the engine fan control solenoid, more oil is bypassed. The fan pump will now drive the fan at a lower rpm.If the ECM detects a system fault, the ECM provides minimum current to the solenoid. Minimum current ensures a maximum fan speed while the fault condition exists.An override is available with Cat® Electronic Technician (ET). An override allows the fan to be manually changed from the minimum to the maximum rpm.Refer to the machine specific Schematic for the location of the component pinouts for electrical connectors and ECM.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Active Codes
A. Remove the electrical power from the ECM.
B. Verify that the solenoid connector is free of debris and connected securely.
C. Connect Cat ET to the service tool connector.
D. Restore the electrical power to the ECM.
E. Select diagnostic tests from Cat ET.
F. Select the "Override Parameters" screen on Cat ET.
G. Activate the fan override.
H. Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes.
Wait at least 30 seconds in order for the code to become active.
I. Disable the fan override.
Active Diagnosti Codes
Result: No codes are active.
The problem may have been related to a faulty connection in the harness. Carefully inspect the connectors and wiring. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Result: A short
Parts switch Caterpillar catalog:
1632657
SWITCH AS-
Caterpillar
Caterpillar
1632653
SWITCH AS-
Caterpillar
Caterpillar
1632652
SWITCH AS-
Caterpillar
Caterpillar
1632651
SWITCH AS-
Caterpillar
Caterpillar
1632650
SWITCH AS-
Caterpillar
Caterpillar
1632649
SWITCH AS-
Caterpillar
Caterpillar
1648435
SWITCH AS-
Caterpillar
Caterpillar
1648434
SWITCH AS-
Caterpillar
Caterpillar
1648433
SWITCH AS-
Caterpillar
Caterpillar
1648431
SWITCH AS-
Caterpillar
Caterpillar
1648430
SWITCH AS-
Caterpillar
Caterpillar
1648429
SWITCH AS-
Caterpillar
Caterpillar