1979123 SWITCH GP-SHUTDOWN Caterpillar parts
69D, AD30, AD45, AD45B, AD55, AD55B, AE40 II, R1300G II, R1600, R1600G, R1700G, R2900, R2900G, R3000H
Rating:
Alternative (cross code) number:
CA1979123
197-9123
1979123
CA1979123
197-9123
1979123
Weight: 0.50 pounds 0 kg.
LOAD HAUL DUMP, UNDERGROUND ART TRUCK,
This part in 2 request:
Show.
This information for suppliers only!
2022-11-09
2022-05-25
Compatible equipment models: 1979123:
Information:
Alarm Indicators
Yellow Warning Lamp (4) - A flashing yellow light indicates that there are active warnings that have not been acknowledged. A continuous yellow light indicates that there are acknowledged warnings that are active. If there are any active warnings, the yellow light will change from flashing yellow to continuous yellow after the "ACKNOWLEDGE" key is pressed. If there are no longer any active warnings, the yellow light will turn off after the "ACKNOWLEDGE" key is pressed.Red Shutdown Lamp (5) - A flashing red light indicates that there are active shutdowns that have not been acknowledged. A continuous red light indicates that there are active shutdowns that have been acknowledged. If there are any active shutdowns the red light will change from flashing red to continuous red after the "ACKNOWLEDGE" key is pressed. Any condition that has caused a shutdown must be manually reset. If there are no longer any active shutdowns, the red light will turn off.Digital Inputs
Note: There are 8 digital inputs on "EMCP 3.2" and "EMCP 3.3". There are 6 digital inputs on "EMCP 3.1".Digital Input 1 - Digital Input 1 is used for the emergency stop. This input should be wired to GROUND through an Emergency Stop switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). Activating the emergency stop input will cause the generator set to stop immediately. The emergency stop input will also prevent the generator set from starting. Once Digital Input 1 goes active, the engine will not start until the event has been cleared. Refer to System Operation, Troubleshooting, Testing and Adjusting, RENR7902, "Digital Input Resetting".Digital Input 2 - Digital Input 2 is used for remotely starting and stopping the generator set. This input should be wired to GROUND through a switch that can be initiated remotely. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the input is active and the engine is in AUTO, the engine will attempt to start. Once the input becomes inactive, the engine will enter into cooldown mode (if programmed) and then the engine will stop.The remainder of the inputs can be configured. The main purpose for the other "DIGITAL" inputs is to add additional monitoring capabilities of the parameters for the engine or generator. The inputs can be configured by going to the "EVENT I/P FUNCTIONS" parameter under the "SETPOINTS" menu. The "DIGITAL INPUTS" parameter can only be set to "ACTIVE HIGH" or "ACTIVE LOW" in order to initiate a High Warning, Low Warning, High Shutdown, Low Shutdown, or Status. The inputs can be programmed to monitor the following parameters or components. Refer to System Operation, Troubleshooting, Testing and Adjusting, RENR7902, "Digital Input Programming".Pressures
Air filter differential pressure
Engine oil pressure
Fire extinguisher pressure
Fuel filter differential pressure
Oil filter differential pressure
Starting air pressureTemperatures
Ambient air temperature
Engine coolant temperature
Engine oil temperature
Exhaust temperature
Rear bearing temperature
Right exhaust temperature
Left exhaust temperatureLevels
Engine coolant level
Engine oil level
Fuel level
External
Yellow Warning Lamp (4) - A flashing yellow light indicates that there are active warnings that have not been acknowledged. A continuous yellow light indicates that there are acknowledged warnings that are active. If there are any active warnings, the yellow light will change from flashing yellow to continuous yellow after the "ACKNOWLEDGE" key is pressed. If there are no longer any active warnings, the yellow light will turn off after the "ACKNOWLEDGE" key is pressed.Red Shutdown Lamp (5) - A flashing red light indicates that there are active shutdowns that have not been acknowledged. A continuous red light indicates that there are active shutdowns that have been acknowledged. If there are any active shutdowns the red light will change from flashing red to continuous red after the "ACKNOWLEDGE" key is pressed. Any condition that has caused a shutdown must be manually reset. If there are no longer any active shutdowns, the red light will turn off.Digital Inputs
Note: There are 8 digital inputs on "EMCP 3.2" and "EMCP 3.3". There are 6 digital inputs on "EMCP 3.1".Digital Input 1 - Digital Input 1 is used for the emergency stop. This input should be wired to GROUND through an Emergency Stop switch. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). Activating the emergency stop input will cause the generator set to stop immediately. The emergency stop input will also prevent the generator set from starting. Once Digital Input 1 goes active, the engine will not start until the event has been cleared. Refer to System Operation, Troubleshooting, Testing and Adjusting, RENR7902, "Digital Input Resetting".Digital Input 2 - Digital Input 2 is used for remotely starting and stopping the generator set. This input should be wired to GROUND through a switch that can be initiated remotely. The input can be set to activate on an active high (normally closed contact) or an active low (normally open contact). If the input is active and the engine is in AUTO, the engine will attempt to start. Once the input becomes inactive, the engine will enter into cooldown mode (if programmed) and then the engine will stop.The remainder of the inputs can be configured. The main purpose for the other "DIGITAL" inputs is to add additional monitoring capabilities of the parameters for the engine or generator. The inputs can be configured by going to the "EVENT I/P FUNCTIONS" parameter under the "SETPOINTS" menu. The "DIGITAL INPUTS" parameter can only be set to "ACTIVE HIGH" or "ACTIVE LOW" in order to initiate a High Warning, Low Warning, High Shutdown, Low Shutdown, or Status. The inputs can be programmed to monitor the following parameters or components. Refer to System Operation, Troubleshooting, Testing and Adjusting, RENR7902, "Digital Input Programming".Pressures
Air filter differential pressure
Engine oil pressure
Fire extinguisher pressure
Fuel filter differential pressure
Oil filter differential pressure
Starting air pressureTemperatures
Ambient air temperature
Engine coolant temperature
Engine oil temperature
Exhaust temperature
Rear bearing temperature
Right exhaust temperature
Left exhaust temperatureLevels
Engine coolant level
Engine oil level
Fuel level
External
Caterpillar SIS machinery equipment:
Caterpillar SIS
R3000H Load Haul Dump RCY00001-UP (MACHINE) POWERED BY C15 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD55 Underground Articulated Truck GNW00001-UP (MACHINE) POWERED BY C18 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD55 Underground Articulated Truck DNW00001-UP (MACHINE) POWERED BY C18 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD45B Underground Articulated Truck CXM00001-UP (MACHINE) POWERED BY C18 Engine »
197-9123
SWITCH GP-SHUTDOWN
R1300G Series II Load Haul Dump RSL00001-UP (MACHINE) POWERED BY C6.6 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD30 Underground Articulated Truck DXR00001-UP (MACHINE) POWERED BY C15 Engine »
197-9123
SWITCH GP-SHUTDOWN
R2900G Load Haul Dump JLK00001-UP (MACHINE) POWERED BY C15 Engine »
197-9123
SWITCH GP-SHUTDOWN
R1700G Load Haul Dump SBR00001-UP (MACHINE) POWERED BY C11 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD55B Underground Articulated Truck JNW00001-UP (MACHINE) POWERED BY C27 Engine »
197-9123
SWITCH GP-SHUTDOWN
R1600G Load Haul Dump 9YZ00001-UP (MACHINE) POWERED BY 3176C Engine »
197-9123
SWITCH GP-SHUTDOWN
R3000H Load Haul Dump RCM00001-UP (MACHINE) POWERED BY C15 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD30 Underground Articulated Truck GXR00001-UP (MACHINE) POWERED BY C15 Engine »
197-9123
SWITCH GP-SHUTDOWN
R1700G Load Haul Dump XBR00001-UP (MACHINE) POWERED BY C11 Engine »
197-9123
SWITCH GP-SHUTDOWN
Command for Underground MXY00001-UP (MACHINE) »
197-9123
SWITCH GP-SHUTDOWN
AD45B Underground Articulated Truck GXM00001-UP (MACHINE) POWERED BY C18 Engine »
197-9123
SWITCH GP-SHUTDOWN
AD60 Underground Articulated Truck NNW00001-UP (MACHINE) POWERED BY C27 Engine »
197-9123
SWITCH GP-SHUTDOWN
Caterpillar parts catalog:
Parts switch Caterpillar catalog:
1727071
SWITCH GP-PRESSURE
725, 730, 735, 740, AD40, AD45, AE40, AE40 II, C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35-C18I, R1700G, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
725, 730, 735, 740, AD40, AD45, AE40, AE40 II, C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35-C18I, R1700G, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
3553148
SWITCH AS-PRESSURE
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 24M, 525D, 535D, 545D, 555D, 583T, 587T, 621...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 24M, 525D, 535D, 545D, 555D, 583T, 587T, 621...
3E7692
SWITCH AS-PRESSURE
525B, 535B, 725, 730, 735, 740, 924G, 924GZ, 953C, 963B, 963C, D5M, D6M, IT28G, R1600, R1600G, R1700 II, R1700G, R2900G, R3000H
525B, 535B, 725, 730, 735, 740, 924G, 924GZ, 953C, 963B, 963C, D5M, D6M, IT28G, R1600, R1600G, R1700 II, R1700G, R2900G, R3000H
3E6451
SWITCH GP-TEMPERATURE
140G, 517, 527, 561M, 631E, 633E II, 637E, 735, 735B, 740, 740B, 777C, 777D, 824C, 918F, 924F, 928F, 950F II, 953B, 963B, 980C, CB-634, CB-634C, CS-531C, CS-531D, CS-533C, CS-533D, CS-563C, CS-563D, C...
140G, 517, 527, 561M, 631E, 633E II, 637E, 735, 735B, 740, 740B, 777C, 777D, 824C, 918F, 924F, 928F, 950F II, 953B, 963B, 980C, CB-634, CB-634C, CS-531C, CS-531D, CS-533C, CS-533D, CS-563C, CS-563D, C...
3E8769
SWITCH AS
24H, 5130, 5130B, 515, 5230B, 525, 525B, 533, 535B, 543, 545, 69D, 769D, 771D, 773D, 775D, 776D, 777D, 785C, 789C, 793C, 844, 854G, 953B, 953C, 963B, 963C, 973, 988F, 988F II, 990, 990 II, 992D, 992G,...
24H, 5130, 5130B, 515, 5230B, 525, 525B, 533, 535B, 543, 545, 69D, 769D, 771D, 773D, 775D, 776D, 777D, 785C, 789C, 793C, 844, 854G, 953B, 953C, 963B, 963C, 973, 988F, 988F II, 990, 990 II, 992D, 992G,...
2M9346
SWITCH AS-PRESSURE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 613C, 613C II, 615, 61...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 613C, 613C II, 615, 61...
7V5647
SWITCH AS-LIMIT
613C, 69D, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777B, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 814B, 815B, 824C, 825C, 826C, 916...
613C, 69D, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777B, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 814B, 815B, 824C, 825C, 826C, 916...
3E2034
SWITCH AS-PRESSURE
621G, 623G, 627G, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, ...
621G, 623G, 627G, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 768C, 769C, 769D, 771C, 771D, 772B, 773B, 773D, 773E, 775B, 775D, 775E, 776C, 776D, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, ...
1056117
SWITCH AS-LIMIT
621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725C, 730C, 735B, 740B, 814F, 814F II, 815F, 815F II, 816F, 816F II, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, ...
621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725C, 730C, 735B, 740B, 814F, 814F II, 815F, 815F II, 816F, 816F II, 824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, ...
1056118
SWITCH AS-LIMIT
621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 814F, 815F, 816F, 824G, 825G, 826G, 918F, 924F, 938F, 950F, 950F II, 950G, 960F, 962G, 966F, 966F II, 966G, 970F, 972G, 980G, IT18F, IT24F, IT28...
621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 814F, 815F, 816F, 824G, 825G, 826G, 918F, 924F, 938F, 950F, 950F II, 950G, 960F, 962G, 966F, 966F II, 966G, 970F, 972G, 980G, IT18F, IT24F, IT28...
1701326
SWITCH AS-ROCKER
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785C, 789C, 793C, AD30, AD45B, AD55, AD55B, AD60
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785C, 789C, 793C, AD30, AD45B, AD55, AD55B, AD60
1701301
SWITCH AS-ROCKER
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785C, 789C, 793C, 797, 797B
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776D, 777D, 784C, 785C, 789C, 793C, 797, 797B
2071321
SWITCH GP-SIGNAL
938G II, IT38G II
938G II, IT38G II
1525279
SWITCH GP-TOGGLE
30/30, DEUCE
30/30, DEUCE
2038489
SWITCH GP-LIMIT
DEUCE
DEUCE
2750929
SWITCH GP-PRESS & TEMP
3013C, 3024, 3024C, C0.5, C1.5, C1.6, C2.2, CB-334E
3013C, 3024, 3024C, C0.5, C1.5, C1.6, C2.2, CB-334E
1294143
SWITCH GP-PRESSURE
988F, 988F II, 992D
988F, 988F II, 992D
2W8957
SWITCH GP
3406B, 3408, 3412
3406B, 3408, 3412
1701329
SWITCH GP-TOGGLE
5110B
5110B