3876527 SWITCH AS-ROCKER Caterpillar parts
Rating:
Alternative (cross code) number:
CA3876527
387-6527
3876527
CA3876527
387-6527
3876527
Weight: 0.06 pounds 0 kg.
Information:
Illustration 1 g01375375
Schematic for the Right Station Decel Pedal Sensor
Illustration 2 g00931873
This diagnostic code is associated with the Right Station Decel Pedal Sensor. The FMI 03 means that the ECM has determined that the voltage of the circuit for the sensor is above normal. Note: The RH Operator ECM is located under the RH Operator Platform.The output frequency of the position sensor is approximately 500 hertz. The duty cycle of the signal changes as the position sensor moves. The duty cycle varies from 5 to 95 percent.A - Approximate position of 10 percent duty cycleB - Approximate position of 50 percent duty cycleC - Approximate position of 90 percent duty cycleThe possible causes of this diagnostic code are listed below:
The signal circuit for the sensor is open.
The signal circuit for the sensor is shorted to the +battery circuit.
The sensor has failed.
The power circuit or the ground circuit has failed.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1726 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the following occurs:
Decel pedal setting will remain at pre-fault setting until the propel lever returns to neutral.
When the propel lever returns to neutral, decel pedal setting will be 50%.
Operator station fault lamp is active.Test Step 1. CHECK FOR POWER AT THE SENSOR.
Do not disconnect the harness connector from the sensor.
Turn the key start switch and the disconnect switch to the ON position.
At the back of the harness connector for the sensor, insert a 7X-1710 Multimeter Probe along the voltage supply wire (contact A).
Measure the voltage from contact A to frame ground.Expected Result:The voltage is 8.0 0.5 DCV.Results:
OK - The voltage is 8.0 0.5 DCV. Proceed to Test Step 2.
NOT OK - The voltage is not 8.0 0.5 DCV. The + battery circuit in
Caterpillar parts catalog:
Parts switch Caterpillar catalog:
3876524
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876523
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876522
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876519
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876518
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3648173
SWITCH GP-PRESSURE
Caterpillar
Caterpillar
3876542
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876539
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876538
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876537
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876533
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876528
SWITCH AS-ROCKER
Caterpillar
Caterpillar