3876543 SWITCH AS-ROCKER Caterpillar parts
Rating:
Alternative (cross code) number:
CA3876543
387-6543
3876543
CA3876543
387-6543
3876543
Weight: 0.05 pounds 0 kg.
Information:
Illustration 1 g02166675
Schematic of the R Conveyor FWD Pump SolenoidThis diagnostic code is associated with the R Conveyor FWD Pump Solenoid. The FMI 03 means that the RH Operator ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.Note: The RH Operator ECM is located under the RH Operator platform.Conditions that could cause this diagnostic code to be active are:
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. This situation is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. System Response:When this diagnostic code is active, the following occurs:
Right conveyor will run at full forward speed.
Operator station fault lamp is active.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness at the solenoid for the R Conveyor FWD Pump hydraulic valve. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from contact J1-48 (wire C733-OR) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire C733-OR and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Troubleshooting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J1 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire C733-OR and socket at contact J1-48 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active CID 1738 FMI 03 diagnostic code.Expected Result:The CID 1738 FMI 03 diagnostic code is no longer active. A CID 1738 FMI 05 diagnostic
Caterpillar parts catalog:
Parts switch Caterpillar catalog:
3876542
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876539
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876538
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876537
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876533
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876528
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876553
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876552
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876549
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876548
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876547
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876544
SWITCH AS-ROCKER
Caterpillar
Caterpillar