3876559 SWITCH AS-ROCKER Caterpillar parts
Rating:
Alternative (cross code) number:
CA3876559
387-6559
3876559
CA3876559
387-6559
3876559
Weight: 0.06 pounds 0 kg.
Information:
Illustration 1 g02076242
Schematic of the R Conveyor Rev Pump SolenoidThis diagnostic code is associated with the R Conveyor Rev Pump Solenoid. The FMI 06 means that the RH Operator ECM has detected that the current for the solenoid circuit is above normal. Note: The RH Operator ECM is located under the RH Operator platform.Conditions that could cause this diagnostic code to be activated are:
The energize circuit of the solenoid is shorted to a ground source.
The solenoid has failed.
The ECM has failed. This is unlikely. System Response:When this diagnostic code is active, the following occurs:
Right conveyor reverse is disabled.
Operator station fault lamp is active.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the machine harness at the solenoid for the R Conveyor Rev Pump hydraulic valve. Expected Result:The active CID 2550 FMI 06 diagnostic code changes to a CID 2550 FMI 05 diagnostic code when the solenoid is disconnected.Results:
YES - The active CID 2550 FMI 06 diagnostic code changes to a CID 2550 FMI 05 diagnostic code when the solenoid is disconnected. The solenoid circuit in the machine harness is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. The resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F). Replace the solenoid.STOP
NO - The CID 2550 FMI 06 diagnostic code remains active. Disconnecting the solenoid did not change the status of the active diagnostic code. The solenoid is not causing the problem. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUNDThe solenoid remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness ECM connectors J1 and J2 from the ECM.
At the machine harness ECM connectors, measure the resistance from the signal contact J1-49 (wire A971-BU) to frame ground. Measure the resistance from the signal contact J1-49 (wire A971-BU) to all of the other contacts that are used in J1 and J2 ECM connectors.
While observing the multimeter resistance measurements, wiggle the machine harness connectors for the ECM and the solenoid. Gently pull on the wires and move the wires around.Expected Result:Each resistance measurement is
Cat SIS web machinery list:
Parts switch Caterpillar catalog:
3876558
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876557
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876556
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876555
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876554
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876553
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876583
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876582
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876579
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876578
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876577
SWITCH AS-ROCKER
Caterpillar
Caterpillar
3876569
SWITCH AS-ROCKER
Caterpillar
Caterpillar