4W8735 SWITCH-STOP Caterpillar parts
3208, 3304, 3304B, 3306, 3406, 3406B, 3408, 3408C, 3412, 3412C, 3508, 3512, 3516, 3516B, C15, C18, G3306, G3406, G3408, G3408B, G3412, G3508, G3512, G3516, PM3412, SR4
Rating:
Alternative (cross code) number:
CA4W8735
4W-8735
4W8735
CA4W8735
4W-8735
4W8735
Weight: 0.50 pounds 0 kg.
GAS ENGINE, POWER MODULE,
Information:
Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. When each phase carries the same load, the engine can work at the rated capacity. If one phase current exceeds the nameplate amperage, an electrical unbalance can result in an electrical overload and overheating.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
Block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load (power factor for the load)
The percentage of load before the application of the block loadIf derating for the block load is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor represents the efficiency of the load. Power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. For example, a 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. A higher power factor will result in full engine load at less than the rated amperage of the generator. A lower power factor increases the possibility of overloading the generator.Note: If no other power factor is specified, Caterpillar generators are designed for a 0.8 lagging power factor. Excitation Systems
Permanent Magnet Pilot Excited Generators
Permanent Magnet Pilot Excited (PMPE) generators receive power for the voltage regulator from a pilot exciter, rather than the main armature. The pilot exciter consists of a permanent magnet rotor and a permanent magnet stator. The pilot exciter operates independently from the generator output voltage. Constant excitation during a large
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. When each phase carries the same load, the engine can work at the rated capacity. If one phase current exceeds the nameplate amperage, an electrical unbalance can result in an electrical overload and overheating.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
Block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load (power factor for the load)
The percentage of load before the application of the block loadIf derating for the block load is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor represents the efficiency of the load. Power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. For example, a 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. A higher power factor will result in full engine load at less than the rated amperage of the generator. A lower power factor increases the possibility of overloading the generator.Note: If no other power factor is specified, Caterpillar generators are designed for a 0.8 lagging power factor. Excitation Systems
Permanent Magnet Pilot Excited Generators
Permanent Magnet Pilot Excited (PMPE) generators receive power for the voltage regulator from a pilot exciter, rather than the main armature. The pilot exciter consists of a permanent magnet rotor and a permanent magnet stator. The pilot exciter operates independently from the generator output voltage. Constant excitation during a large
Cat SIS web machinery list:
Parts switch Caterpillar catalog:
3012980
SWITCH AS-TOGGLE
236D, 242D, 257D, 259D, 272D, 272D XHP, 299D, 299D XHP, 3126B, 3512C, 3516B, 621G, 623G, 627G, 631G, 637G, 657G, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, 938H, 95...
236D, 242D, 257D, 259D, 272D, 272D XHP, 299D, 299D XHP, 3126B, 3512C, 3516B, 621G, 623G, 627G, 631G, 637G, 657G, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, 938H, 95...
6T4949
SWITCH AS
225, 225D, 229, 229D, 231D, 3306, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 426, 428, 578, 589, D10N, D11N, D5B, D8L, D8N, D8R, D9L, D9N, G3408, G3412
225, 225D, 229, 229D, 231D, 3306, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 426, 428, 578, 589, D10N, D11N, D5B, D8L, D8N, D8R, D9L, D9N, G3408, G3412
3L6306
SWITCH AS
12G, 140G, 14G, 16G, 3306, 3306B, 627, 627B, 637B, 637D, 657B, 666, 768C, 769C, 772B, 773B, 777, 777B, 784B, 785, 785B, 789, 789B, 793B, 977K, 983, D250B, D25C, D300B, D30C, D320A, D330A, D333A, D350C...
12G, 140G, 14G, 16G, 3306, 3306B, 627, 627B, 637B, 637D, 657B, 666, 768C, 769C, 772B, 773B, 777, 777B, 784B, 785, 785B, 789, 789B, 793B, 977K, 983, D250B, D25C, D300B, D30C, D320A, D330A, D333A, D350C...
7N5946
SWITCH
3304, 3304B, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3412, 3508, 3512, 3516, AP-1000B, AP-1055B, AP-800C, BG-225B, BG-225C, BG-2455C, BG-245C, CB-534
3304, 3304B, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3412, 3508, 3512, 3516, AP-1000B, AP-1055B, AP-800C, BG-225B, BG-225C, BG-2455C, BG-245C, CB-534
2N9768
SWITCH-LIQUID LEVEL
3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 3618, C12, C18, C280-12...
3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 3618, C12, C18, C280-12...
9X8124
SWITCH AS-MAGNETIC
311, 311B, 3126B, 312B, 312C, 312C L, 313B, 314C, 315, 315B, 315B FM L, 315C, 317B LN, 318B, 318C, 319C, 320 L, 3208, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320N, 321B, 322, 322 FM L, 325, 325 L, 32...
311, 311B, 3126B, 312B, 312C, 312C L, 313B, 314C, 315, 315B, 315B FM L, 315C, 317B LN, 318B, 318C, 319C, 320 L, 3208, 320B, 320B FM LL, 320B L, 320C, 320C FM, 320N, 321B, 322, 322 FM L, 325, 325 L, 32...
5N0612
SWITCH-ROTARY
3208, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, G3306, G3306B, G3406, G3408, G3412, G3508, G3512, G3512E, G3516, G35...
3208, 3306, 3306B, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, G3306, G3306B, G3406, G3408, G3412, G3508, G3512, G3512E, G3516, G35...
2266446
SWITCH AS-PUSH BUTTON
3054, 3056, 3306B, 3406C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C1.5, C13, C15, C18, C2.2, C27, C3.3, C4.4, C6.6, C7.1, C9
3054, 3056, 3306B, 3406C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C1.5, C13, C15, C18, C2.2, C27, C3.3, C4.4, C6.6, C7.1, C9
2S2342
SWITCH ASSEM. (Heat and Start)
12E, 14E, 16, 1673C, 1674, 1676, 1693, 3304, 3306, 561B, 561C, 621, 627, 631C, 637, 641, 641B, 650B, 657, 657B, 666, 666B, 769, 824B, 834, 941, 950, 951B, 955K, 955L, 966C, 977H, 977K, 980, 988, 992, ...
12E, 14E, 16, 1673C, 1674, 1676, 1693, 3304, 3306, 561B, 561C, 621, 627, 631C, 637, 641, 641B, 650B, 657, 657B, 666, 666B, 769, 824B, 834, 941, 950, 951B, 955K, 955L, 966C, 977H, 977K, 980, 988, 992, ...
2P4749
SWITCH ASSEM.
225, 3160, 3208, 3304, 3306, 613, 613B, D342C, D346, D399, G343
225, 3160, 3208, 3304, 3306, 613, 613B, D342C, D346, D399, G343
3N9596
SWITCH (speed)
3406, 3408, D348, D353C, D379B, D399, G399
3406, 3408, D348, D353C, D379B, D399, G399
9W3187
SWITCH AS-PRESSURE
120G, 12G, 12H ES, 12H NA, 130G, 140G, 140H ES, 140H NA, 143H, 14G, 160G, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 578, 589, 613C, 615C, 621E, 621F, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 768C, 769C...
120G, 12G, 12H ES, 12H NA, 130G, 140G, 140H ES, 140H NA, 143H, 14G, 160G, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 578, 589, 613C, 615C, 621E, 621F, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 768C, 769C...
3N5976
SWITCH
3054, 3056, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3512, 3516, 3516B, 3606, 3608, 3612, 3616, C15, C18, C32, G3306, G3406, G3408, G3408B, G3412, G3508, G35...
3054, 3056, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3512, 3516, 3516B, 3606, 3608, 3612, 3616, C15, C18, C32, G3306, G3406, G3408, G3408B, G3412, G3508, G35...
9G8010
SWITCH AS-PRESSURE
120B, 120G, 12G, 130G, 140B, 140G, 14G, 16G, 227, 235, 235C, 245, 245B, 245D, 3304, 3306, 3306B, 3406, 3406B, 3408, 3408C, 3412, 3412D, 3508, 3508C, 3512, 3516, 561D, 571G, 572G, 583K, 594H, 615, 651E...
120B, 120G, 12G, 130G, 140B, 140G, 14G, 16G, 227, 235, 235C, 245, 245B, 245D, 3304, 3306, 3306B, 3406, 3406B, 3408, 3408C, 3412, 3412D, 3508, 3508C, 3512, 3516, 561D, 571G, 572G, 583K, 594H, 615, 651E...
2L3402
SWITCH AS
120, 12F, 12G, 140, 140G, 14E, 14G, 16, 16G, 225, 225D, 227, 229, 3160, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3512, 3516, 594, 613, 621, 623...
120, 12F, 12G, 140, 140G, 14E, 14G, 16, 16G, 225, 225D, 227, 229, 3160, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3512, 3516, 594, 613, 621, 623...
8N1693
SWITCH AS-TEMPERATURE
120G, 12G, 130G, 140G, 14G, 16G, 16H NA, 231D, 245D, 307, 312, 315, 317, 3208, 3304, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3508, 3512, 3516, 375, 375 L, 428, 436, 508, 5080, 578, 589, 611, 613...
120G, 12G, 130G, 140G, 14G, 16G, 16H NA, 231D, 245D, 307, 312, 315, 317, 3208, 3304, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3508, 3512, 3516, 375, 375 L, 428, 436, 508, 5080, 578, 589, 611, 613...
9D3721
SWITCH-TOGGLE
120G, 130G, 16G, 225D, 227, 231D, 235C, 235D, 245B, 245D, 30/30, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516...
120G, 130G, 16G, 225D, 227, 231D, 235C, 235D, 245B, 245D, 30/30, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516...
4N9072
SWITCH AS-FLOW
120G, 12G, 16G, 3306, 627B, 920, D6C
120G, 12G, 16G, 3306, 627B, 920, D6C
1296465
SWITCH AS-ROLLER
416B, 426B, 428B, 438B, CS-531C, CS-533C, CS-563C, CS-573C, CS-583C
416B, 426B, 428B, 438B, CS-531C, CS-533C, CS-563C, CS-573C, CS-583C
1107883
SWITCH GP-START
307, 312, 315, 317, 320B, 322B LN, 325B L, 416B, 416C, 426B, 426C, 428B, 428C, 436C, 438B, 438C, 446B, TH63, TH82, TH83
307, 312, 315, 317, 320B, 322B LN, 325B L, 416B, 416C, 426B, 426C, 428B, 428C, 436C, 438B, 438C, 446B, TH63, TH82, TH83
9X9589
SWITCH AS
416B, 426B, 428B, 438B, 446B
416B, 426B, 428B, 438B, 446B
6T5925
SWITCH AS-LIMIT
302.5, 303.5, 304.5, 416, 416B, 426B, 428, 428B, 436, 446, 446B, 611, 613C II, 615C, 953C, IT18F, PF-290B, PR-1000, PR-450C
302.5, 303.5, 304.5, 416, 416B, 426B, 428, 428B, 436, 446, 446B, 611, 613C II, 615C, 953C, IT18F, PF-290B, PR-1000, PR-450C
7W1238
SWITCH AS-PRESSURE
206, 214, 216, 224, 228, 236, 247, 248, 267, 287, 3054, 3056, 416, 416B, 416D, 424B, 424B HD, 424D, 426B, 428B, 438B, 446, 446B, 906, 914G, 924G, 924GZ, 928G, 938G, CB-434B, CB-434C, CB-534B, CB-534C,...
206, 214, 216, 224, 228, 236, 247, 248, 267, 287, 3054, 3056, 416, 416B, 416D, 424B, 424B HD, 424D, 426B, 428B, 438B, 446, 446B, 906, 914G, 924G, 924GZ, 928G, 938G, CB-434B, CB-434C, CB-534B, CB-534C,...
7W6614
SWITCH-ROTARY
3126, 3208, 3306, 3406B, 3406C, 3408, 3412, 3508, 3512, 3516
3126, 3208, 3306, 3406B, 3406C, 3408, 3412, 3508, 3512, 3516