7E5602 SWITCH AS-PRESSURE Caterpillar parts
3114, 3116, 3126
Rating:
Alternative (cross code) number:
CA7E5602
7E-5602
7E5602
CA7E5602
7E-5602
7E5602
Weight: 0.13 pounds 0 kg.
Information:
ACTUATION PRESSURE
241 KPA
kPa
CONNECTOR TYPE
PACKARD
DEACTUATION PRESSURE
241 KPA
kPa
THREAD SIZE
.25-18NPTF
AMP.[RESISTIVE]
10A
CONTACT PRESSURE-MAX.
1034 KPA
CONATCT POSITION
NO
OPEN CYCLE LIFE
500000
SENSED MEDIA
OIL-VAC-AIR
SUPPLY VOLTAGE
14.5V
MARINE ENGINE, TRUCK ENGINE,
This part in 5 request:
Show.
This information for suppliers only!
2025-05-07
2023-10-08
2020-08-16
2019-12-17
2017-01-02
Information:
Problem-Remote CAN Network receives no data from Local CAN Network
Probable Cause
Confirm the PL1000T Communications ECM is properly connected to system power. Confirm that Batt+ is applied to the key switch circuit.
Confirm all devices on the CAN networks that are connected to the PL1000T are functioning properly. Confirm all devices on the CAN networks that are connected to the PL1000T are configured for 250K baud rate.
Confirm the CAN "Extension Bridge Function Enable Status", that is displayed on the PL1000T "Configuration" screen, is configured to "Enabled".
Connect to Caterpillar Communication Adapter. Confirm that each device is detected that is on the logical CAN network and that is connected to the "CAN Port 1" of each PL1000T.
If no devices are detected, connect the Comm Adapter II to one of the physical CAN networks connected to either of the PL1000T ECMs.
Confirm that the devices are detected that are connected to that network. If no devices are detected, then the harnessing must be analyzed and repaired.
If devices are detected, then connect the Comm Adapter II to the other physical CAN network of the other PL1000T. Confirm that the devices are detected that are on that physical network. If no devices are detected, then the harnessing must be analyzed and repaired.
If all devices are detected in both previous connections, then the RS-485 harnessing should be analyzed and repaired.Problem-Remote CAN Network receives partial data from Local CAN Network
Probable Cause
Confirm all devices on the CAN networks that are connected to the PL1000T are functioning properly. Confirm all devices on the CAN networks that are connected to the PL1000T are configured for 250K baud rate.
Using the Communication Adapter, start the service tool and confirm that the devices connected to "CAN Port 1" of each PL1000T ECM are detected. If some of the devices are not detected, the harnessing that is on that CAN port must be analyzed and repaired.
Use Cat service tool in order to monitor the "CAN Extension Bridge Statistics" screen. The number of messages received on "CAN Port 1" should increment at approximately the same rate as the number of messages transmitted on "CAN Port 2". A potential cause of receiving partial data is an intermittent harness failure. An intermittent harness failure will cause the two messaging counters to become dissimilar over a short time.Problem-Excessive data latency from Local to Remote CAN Network
Probable Cause
Disable all other PL1000T ECM features. Observe the data flow. If the data flow has improved, the CAN buss loading is excessive. An additional PL1000T ECM must be used in the system in order to implement the other desired features. If the PL1000T ECM is used in order to connect two separate CAN busses, data flow could be improved with separate PL1000T ECMs. Separate PL1000T ECMs would provide the "CAN Extension Bridge" for each network.
The possibility exists that high CAN buss loading may exceed the processing ability of the PL1000T ECM. The CAN buss loading must be analyzed and reduced if possible.
Probable Cause
Confirm the PL1000T Communications ECM is properly connected to system power. Confirm that Batt+ is applied to the key switch circuit.
Confirm all devices on the CAN networks that are connected to the PL1000T are functioning properly. Confirm all devices on the CAN networks that are connected to the PL1000T are configured for 250K baud rate.
Confirm the CAN "Extension Bridge Function Enable Status", that is displayed on the PL1000T "Configuration" screen, is configured to "Enabled".
Connect to Caterpillar Communication Adapter. Confirm that each device is detected that is on the logical CAN network and that is connected to the "CAN Port 1" of each PL1000T.
If no devices are detected, connect the Comm Adapter II to one of the physical CAN networks connected to either of the PL1000T ECMs.
Confirm that the devices are detected that are connected to that network. If no devices are detected, then the harnessing must be analyzed and repaired.
If devices are detected, then connect the Comm Adapter II to the other physical CAN network of the other PL1000T. Confirm that the devices are detected that are on that physical network. If no devices are detected, then the harnessing must be analyzed and repaired.
If all devices are detected in both previous connections, then the RS-485 harnessing should be analyzed and repaired.Problem-Remote CAN Network receives partial data from Local CAN Network
Probable Cause
Confirm all devices on the CAN networks that are connected to the PL1000T are functioning properly. Confirm all devices on the CAN networks that are connected to the PL1000T are configured for 250K baud rate.
Using the Communication Adapter, start the service tool and confirm that the devices connected to "CAN Port 1" of each PL1000T ECM are detected. If some of the devices are not detected, the harnessing that is on that CAN port must be analyzed and repaired.
Use Cat service tool in order to monitor the "CAN Extension Bridge Statistics" screen. The number of messages received on "CAN Port 1" should increment at approximately the same rate as the number of messages transmitted on "CAN Port 2". A potential cause of receiving partial data is an intermittent harness failure. An intermittent harness failure will cause the two messaging counters to become dissimilar over a short time.Problem-Excessive data latency from Local to Remote CAN Network
Probable Cause
Disable all other PL1000T ECM features. Observe the data flow. If the data flow has improved, the CAN buss loading is excessive. An additional PL1000T ECM must be used in the system in order to implement the other desired features. If the PL1000T ECM is used in order to connect two separate CAN busses, data flow could be improved with separate PL1000T ECMs. Separate PL1000T ECMs would provide the "CAN Extension Bridge" for each network.
The possibility exists that high CAN buss loading may exceed the processing ability of the PL1000T ECM. The CAN buss loading must be analyzed and reduced if possible.
Caterpillar parts catalog:
Parts switch Caterpillar catalog:
1183534
SWITCH GP-MAGNETIC
120H, 120K, 120K 2, 12H, 12K, 135H, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 16M, 24M, 30/30, 3126, 5110B, 5130B, 533, 539, 543, 550B, 554, 560B, 574, 69D, 725, 730, 735, 740, 769D, 770, ...
120H, 120K, 120K 2, 12H, 12K, 135H, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 16M, 24M, 30/30, 3126, 5110B, 5130B, 533, 539, 543, 550B, 554, 560B, 574, 69D, 725, 730, 735, 740, 769D, 770, ...
1125475
SWITCH-WATER TEMPERATURE
3114, 3116, 3126
3114, 3116, 3126
1076250
SWITCH AS-TEMPERATURE
3114, 3116
3114, 3116
1487411
SWITCH GP
3116, 3126, 3126B
3116, 3126, 3126B
1436715
SWITCH
3116, 3126, 3126B
3116, 3126, 3126B
1546417
SWITCH
3116, 3126, 3126B
3116, 3126, 3126B
1546419
SWITCH AS-TEMPERATURE
3116, 3126, 3126B
3116, 3126, 3126B
1578764
SWITCH
3116, 3126, 3126B
3116, 3126, 3126B
1376604
SWITCH AS-PRESSURE
3116, 3126, 3126B, 3126E
3116, 3126, 3126B, 3126E
1442569
SWITCH AS
3116
3116
1442593
SWITCH AS
3116
3116
1125475
SWITCH-WATER TEMPERATURE
3114, 3116, 3126
3114, 3116, 3126
1179081
SWITCH AS-MAGNETIC
120H, 120K, 120K 2, 12K, 135H, 140H, 140K, 140K 2, 143H, 160H, 160K, 163H, 16H, 16M, 24M, 3126, 554, 574, 725, 730, 735, 740, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773D, 773E, 773F, 77...
120H, 120K, 120K 2, 12K, 135H, 140H, 140K, 140K 2, 143H, 160H, 160K, 163H, 16H, 16M, 24M, 3126, 554, 574, 725, 730, 735, 740, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773D, 773E, 773F, 77...
3E7789
SWITCH AS-STOP
3408B, 3412
3408B, 3412
4D3662
SWITCH-MAGNETIC
12E, 16, 3408B, 3412, 3412E, 621, 641, 651, 657, 666, 824, 834, 955K, 977H, 977K, 980, 988, D4D
12E, 16, 3408B, 3412, 3412E, 621, 641, 651, 657, 666, 824, 834, 955K, 977H, 977K, 980, 988, D4D
9G8011
SWITCH AS
130G, 14G, 16G, 3208, 615, 651E, 657E, 776, 777, 814B, 815B, 824C, 826C, 920, 930, 936, 943, 950B, 950B/950E, 953, 963, 966D, 973, 980C, 988B, 992C, D10, D250B, D300B, D6H, D7H, D8L, D9L
130G, 14G, 16G, 3208, 615, 651E, 657E, 776, 777, 814B, 815B, 824C, 826C, 920, 930, 936, 943, 950B, 950B/950E, 953, 963, 966D, 973, 980C, 988B, 992C, D10, D250B, D300B, D6H, D7H, D8L, D9L
3E7389
SWITCH-PUSH BUTTON
3116, 3126, 3208, 320D, 320D FM, 320D L, 320D LN, 320D2, 320D2 L, 320E, 320E L, 320E LN, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 324D L, 324D LN, 324E L, 324E LN, 325B, 325D, 325D L, 329D, 32...
3116, 3126, 3208, 320D, 320D FM, 320D L, 320D LN, 320D2, 320D2 L, 320E, 320E L, 320E LN, 323D L, 323D LN, 323D SA, 323D2 L, 323E L, 324D, 324D L, 324D LN, 324E L, 324E LN, 325B, 325D, 325D L, 329D, 32...
1272331
SWITCH AS-ROTARY
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C18
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C18
6T1767
SWITCH GP-TOGGLE
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 980C, AD40, AD45, AE40, AE40 II, AP-1000B, AP-1055B, AP-1055D, AP-650B, AP-655C, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, PM-201, PM-5...
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 980C, AD40, AD45, AE40, AE40 II, AP-1000B, AP-1055B, AP-1055D, AP-650B, AP-655C, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, PM-201, PM-5...
8T9637
SWITCH AS-TOGGLE
3304B, 3408, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C7.1, RM-350B
3304B, 3408, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C7.1, RM-350B
1157846
SWITCH-ROTARY
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
2632905
SWITCH AS-LIMIT
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C27, C32, SPF343, SPS343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C27, C32, SPF343, SPS343, SPT343
2277483
SWITCH AS-LIMIT
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, SPF343, SPS343, SPT343
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, SPF343, SPS343, SPT343