9W2150 SWITCH AS-NEUTRAL START Caterpillar parts
215C, 215D, 225D, 227, 229, 229D, 231D, 235B, 235C, 235D, 245, 245B, 245D, 307, 311, 312, 315, 317, 320 L, 320N, 322, 322 FM L, 322 LN, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080,...
Rating:
Alternative (cross code) number:
CA9W2150
9W-2150
9W2150
CA9W2150
9W-2150
9W2150
Weight: 0.12 pounds 0 kg.
Information:
AMPERAGE
4
CONNECTION TYPE
SCREW
NUMBER OF POLES
1
NUMBER OF POSITIONS
2
NUMBER OF THROWS
1
FUNCTIONALITY
START
EXCAVATOR, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 9W2150:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator's main stator winding. The frequency of this test is determined by the generator's environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every three months.
The generator set is not protected from the elements in an enclosed area. Test every three months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every twelve months (minimum).
The generator set has not been run under load for three months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above one megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester's Black lead to ground.
Connect the insulation tester's RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator's main stator winding. The frequency of this test is determined by the generator's environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every three months.
The generator set is not protected from the elements in an enclosed area. Test every three months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every twelve months (minimum).
The generator set has not been run under load for three months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above one megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester's Black lead to ground.
Connect the insulation tester's RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be
Cat SIS web machinery list:
Parts switch Caterpillar catalog:
3T5825
SWITCH AS
578, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D6H, D6H XL, D6H XR, D7H, D8L, D8N, D8R
578, D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II, D6H, D6H XL, D6H XR, D7H, D8L, D8N, D8R
3E9350
SWITCH AS-TEMPERATURE
2384C, 2484C, 515, 517, 525, 527, 559C, 561M, 579C, 583R, 587R, 789B, 826C, 836, CB-214D, CB-214E, D10R, D11R, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H XL, D6H XR, D6M, D7H, D8R,...
2384C, 2484C, 515, 517, 525, 527, 559C, 561M, 579C, 583R, 587R, 789B, 826C, 836, CB-214D, CB-214E, D10R, D11R, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, D5M, D6H, D6H XL, D6H XR, D6M, D7H, D8R,...
1070616
SWITCH AS-PRESSURE
12H ES, 12H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 517, 527, 611, 615C, 621F, 623E, 623F, 627F, 631E, 633E II, 637E, 824C, 980C, D250E, D350E, D400E, D5H, D5H XL, D5HTS...
12H ES, 12H NA, 140H ES, 140H NA, 143H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 517, 527, 611, 615C, 621F, 623E, 623F, 627F, 631E, 633E II, 637E, 824C, 980C, D250E, D350E, D400E, D5H, D5H XL, D5HTS...
3E2026
SWITCH AS-PRESSURE
120H, 120K, 120K 2, 12H, 12K, 130G, 135H, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 517, 527, 572R, 613C II, 615C, 621B, 627E, 627F, 627G, 637E, 973, 973C, D4H, D4H XL, D4HTSK III, D5H, D5...
120H, 120K, 120K 2, 12H, 12K, 130G, 135H, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 517, 527, 572R, 613C II, 615C, 621B, 627E, 627F, 627G, 637E, 973, 973C, D4H, D4H XL, D4HTSK III, D5H, D5...
9P4608
SWITCH AS
561D, 571G, 572G, 583K, 615, 941, 953, 953B, 953C, 955K, 955L, 977L, 983, 983B, D4E, D5B, D6D, D6E SR, D7G, D8K, D9H
561D, 571G, 572G, 583K, 615, 941, 953, 953B, 953C, 955K, 955L, 977L, 983, 983B, D4E, D5B, D6D, D6E SR, D7G, D8K, D9H
3E8769
SWITCH AS
24H, 5130, 5130B, 515, 5230B, 525, 525B, 533, 535B, 543, 545, 69D, 769D, 771D, 773D, 775D, 776D, 777D, 785C, 789C, 793C, 844, 854G, 953B, 953C, 963B, 963C, 973, 988F, 988F II, 990, 990 II, 992D, 992G,...
24H, 5130, 5130B, 515, 5230B, 525, 525B, 533, 535B, 543, 545, 69D, 769D, 771D, 773D, 775D, 776D, 777D, 785C, 789C, 793C, 844, 854G, 953B, 953C, 963B, 963C, 973, 988F, 988F II, 990, 990 II, 992D, 992G,...
1070613
SWITCH AS-PRESSURE
611, 615C, D6E, D6G, D6G SR, D6G2 LGP, D6G2 XL, D7G, D7G2
611, 615C, D6E, D6G, D6G SR, D6G2 LGP, D6G2 XL, D7G, D7G2
9P9520
SWITCH AS
910, 931, 931B, 931C II, D3, D3B, D4C, D4E, D4E SR, D4H, D5C III, D5H, D6D, D6D SR, D6H, D7H
910, 931, 931B, 931C II, D3, D3B, D4C, D4E, D4E SR, D4H, D5C III, D5H, D6D, D6D SR, D6H, D7H
9X4959
SWITCH AS-PUSH BUTTON
320 L, 910E, 918F, 924F, 928F, 936F, 938F, 950F, 950F II, 960F, 966F II, 970F, 980F, 980F II, 994, 994D, IT12B, IT18F, IT24F, IT28F, IT38F
320 L, 910E, 918F, 924F, 928F, 936F, 938F, 950F, 950F II, 960F, 966F II, 970F, 980F, 980F II, 994, 994D, IT12B, IT18F, IT24F, IT28F, IT38F
1169933
SWITCH AS-PRESSURE
5130, 5130B, 5230, 5230B, 651E, 657E, 776C, 776D, 777D, 784B, 785, 785B, 789B, 793B, 793C, 854G, 992G, 994F, 994H, D11N
5130, 5130B, 5230, 5230B, 651E, 657E, 776C, 776D, 777D, 784B, 785, 785B, 789B, 793B, 793C, 854G, 992G, 994F, 994H, D11N
3E5181
SWITCH AS-LIMIT
322B L, 325B, 325B L, 330B L, 345B, 345B II, 345B L, 365B L, 385B, 385C, 385C L, 5130, 5130B, 5230, 854G, 988F, 992D, 992G, 993K, 994F
322B L, 325B, 325B L, 330B L, 345B, 345B II, 345B L, 365B L, 385B, 385C, 385C L, 5130, 5130B, 5230, 854G, 988F, 992D, 992G, 993K, 994F
1717085
SWITCH AS-LIMIT
365B, 365B II, 365C, 365C L, 374D L, 385B, 385C, 385C L, 390D, 390D L, 5090B, 5230B, 844, 844H, 854K, 988F, 988F II, 990, 990 II, 990H, 992D, 992K, 993K, 994H
365B, 365B II, 365C, 365C L, 374D L, 385B, 385C, 385C L, 390D, 390D L, 5090B, 5230B, 844, 844H, 854K, 988F, 988F II, 990, 990 II, 990H, 992D, 992K, 993K, 994H
1060096
SWITCH AS-PRESSURE
311, 312, 315, 317, 322, 322 FM L, 322 LN, 325 L, 330 L
311, 312, 315, 317, 322, 322 FM L, 322 LN, 325 L, 330 L
7X6387
SWITCH AS-ROCKER
307, 312, 315, 317, 320, 320 L, 322, 322 FM L, 322 LN, 325, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080
307, 312, 315, 317, 320, 320 L, 322, 322 FM L, 322 LN, 325, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080
8J9236
SWITCH
215, 215B, 235, 245, 307, 307B, 311D LRR, 312, 312B L, 312C, 312D, 312D L, 314D LCR, 315, 315B L, 315C, 315D L, 317, 317B LN, 318B, 318C, 319C, 319D, 320B, 320C, 320D, 320D FM, 320D L, 320D LN, 322B L...
215, 215B, 235, 245, 307, 307B, 311D LRR, 312, 312B L, 312C, 312D, 312D L, 314D LCR, 315, 315B L, 315C, 315D L, 317, 317B LN, 318B, 318C, 319C, 319D, 320B, 320C, 320D, 320D FM, 320D L, 320D LN, 322B L...
6C6806
SWITCH AS
307, 312, 315, 317, 320 L, 322 LN, 325 L, 330 L, 350
307, 312, 315, 317, 320 L, 322 LN, 325 L, 330 L, 350
1132375
SWITCH AS-MAGNETIC
312, 315, 317
312, 315, 317
1070611
SWITCH AS-PRESSURE
12H, 140H, 160H, 307, 315, 317, CB-434C, CB-534B, CB-534C, CB-535B, CB-544, CB-545, CB-634C, CP-433C, CP-433E, CP-533E, CS-323C, CS-423E, CS-431C, CS-433C, CS-433E, CS-531C, CS-531D, CS-533C, CS-533D,...
12H, 140H, 160H, 307, 315, 317, CB-434C, CB-534B, CB-534C, CB-535B, CB-544, CB-545, CB-634C, CP-433C, CP-433E, CP-533E, CS-323C, CS-423E, CS-431C, CS-433C, CS-433E, CS-531C, CS-531D, CS-533C, CS-533D,...
1145334
SWITCH AS-PRESSURE
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 307, 312, 315, 317, 320 L, 322 FM L, 322 LN, 325, 325 FM L, 330, 330 L, 3...
120H, 120H ES, 120H NA, 12H ES, 12H NA, 135H, 135H NA, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H ES, 160H NA, 163H NA, 16H NA, 307, 312, 315, 317, 320 L, 322 FM L, 322 LN, 325, 325 FM L, 330, 330 L, 3...
1088161
SWITCH AS-ROTARY
307, 307B, 312, 312B L, 315, 315B L, 317, 317B LN, 318B
307, 307B, 312, 312B L, 315, 315B L, 317, 317B LN, 318B
5I8314
SWITCH AS
312, 315, 317, 320 L, 325, 325 L, 325 LN, 330, 350, 350 L, 375, 375 L, 5080
312, 315, 317, 320 L, 325, 325 L, 325 LN, 330, 350, 350 L, 375, 375 L, 5080
6I5088
SWITCH AS
312, 315, 317, 322 FM L, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5130, 5230
312, 315, 317, 322 FM L, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5130, 5230
1262938
SWITCH AS
311, 312, 315, 317, 320 L, 320N, 322, 322 FM L, 322 LN, 325, 330, 330 L
311, 312, 315, 317, 320 L, 320N, 322, 322 FM L, 322 LN, 325, 330, 330 L