Information:


Illustration 1 g01343159
Connections for the 10 volt sensor supply
The sensor supply is a power supply that is internal to the ECM. The sensor supply provides 10 VDC in order to operate the sensors.This diagnostic code will be recorded when the Transmission ECM reads the voltage for the circuit of the sensor supply as being below normal.The possible causes of the diagnostic code are listed:
10 VDC is shorted to ground between the sensor and the ECM.
The ECM has failed. This is unlikely.System Response:The results of this diagnostic code are listed:
All of the associated sensors will also log diagnostic codes.Test Step 1. CHECK THE SENSOR.
Ensure that the diagnostic code of SPN 1542 FMI 1 is present. The diagnostic code should be active.
Disconnect the machine harness from all of the sensors in the circuit. Expected Result:The diagnostic code is NO longer active.Results:
OK - The diagnostic code is NO longer active. One of the sensors have failed.Repair: Reconnect the sensors one at a time until the diagnostic code becomes active. Replace the sensor that causes the active diagnostic code.STOP
NOT OK - The diagnostic code remains active. The sensors are NOT causing the diagnostic code. Proceed to Test Step 2.Test Step 2. CHECK FOR A SHORT TO GROUND.
The sensors remain disconnected from the machine harness.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness from the ECM.
At the ECM, measure the resistance between the contact of the sensor supply voltage (J1-13) and frame ground. Expected Result:The resistance is greater than 5000 ohms. Results:
OK - The resistance that is measured is greater than 5000 ohms. The harness circuit is correct. The ECM has failed.Repair: It is unlikely that the ECM has failed. Exit this procedure. Perform the diagnostic code procedure for SPN 1542 FMI 1 again. If the cause of the diagnostic code is NOT found, replace the ECM . See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NOT OK - The resistance that is measured is less than 5000 ohms. The machine harness has failed. There is a short between frame ground and the contact for the sensor supply voltage in the machine harness.Repair: Repair the machine harness or replace the machine harness.STOP

Caterpillar parts catalog:

Caterpillar parts catalog
D6E Track-Type Tractor SR 8FJ00001-UP (MACHINE) POWERED BY 3306 Engine
D6G Track-Type Tractor Super Rural 3SR00001-UP (MACHINE) POWERED BY 3306 Engine


Parts tachometer Caterpillar catalog:

2Y9927 TACHOMETER GP-ELECTRIC
D4E, D4E SR, D6D, D6D SR
3T2159 TACHOMETER
3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 3508, 3512, 3516, D348, D379B, D4E, D4E SR, D6D, G3304, G3306, G3406, G3408, G3412, G342C, G3512, G3516, G379, PR-1000
5Y0375 TACHOMETER GP-ELECTRIC
D4E, D4E SR, D6D, D6D SR
8N7902 TACHOMETER AS
615, 621, 621B, 627B, 633D, 637D, 641B, 657B
5Y0375 TACHOMETER GP-ELECTRIC
D4E, D4E SR, D6D, D6D SR
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.