2058384 TAG Caterpillar parts
325B L, 330B L
Rating:
Alternative (cross code) number:
CA2058384
205-8384
2058384
CA2058384
205-8384
2058384
EXCAVATOR,
Information:
Parameter Descriptions
"Equipment ID"
The "Equipment ID" parameter allows the customer to enter a description into the Electronic Control Module (ECM) in order to identify the machine. A maximum of 17 characters can be entered in the field."Engine Serial Number"
Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM."Rating Number"
The "Rating Number" is a reference number that corresponds to the rating map that resides in the personality module. Flash files may contain more than one rating."FLS" (Full Load Setting)
"FLS" is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."FTS" (Full Torque Setting)
"FTS" is similar to "FLS". Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."Engine Fan Control"
The "Engine Fan Control" parameter allows the operation of this feature to be enabled or disabled."Top Engine Fan Speed"
The fan speed is limited between the maximum and minimum limits."Max Deceleration Pedal Pos Eng Spd"
The programmed value is the lowest engine speed that can be obtained with the decelerator pedal. "Engine Security System Status"
This parameter allows the "Engine Security System" to be disabled or removed. If the "Engine Security System" is removed from the machine and this parameter is not programmed to "Disabled", the engine will not start. Factory passwords are required."Engine Oil Weight"
The "Engine Oil Weight" parameter defaults to "Automatic Detection". Do not program this parameter.System Configuration Parameters
Table 1
System Configuration Parameters
Parameter Available Range or Options Default Required Password
"Equipment ID" 17 alphanumeric characters None
"Engine Serial Number" XXX00000 None
"Full Load Setting (FLS)" "Factory Programmed" Factory
"Full Torque Setting (FTS)" "Factory Programmed" Factory
"Engine Fan Control" "On"
"Off" "Off" None
"Top Engine Fan Speed" Unavailable
"Max Deceleration Pedal Pos Eng Spd" 1000 to 1100 rpm "1100 rpm" None
"Engine Security System Status" "Enabled"
"Disabled" "Enabled" Factory
"Engine Oil Weight" "Automatic Detection" "Automatic Detection" None Parameters Worksheet
Note: A mistake in recording this information will result in incorrect passwords.
Table 2
Engine Parameters
"Equipment ID"
"Engine Serial Number"
"ECM Serial Number"
"Personality Module Part Number"
"Personality Module Description"
"FLS"
"FTS"
"Engine Fan Control"
"Top Engine Fan Speed"
"Max Deceleration Pedal Pos Eng Spd"
"Engine Security System Status"
"Engine Oil Weight"
"Total Tattletale"
Table 3
Information from Engine Information Plate
"Engine Serial Number"
"FTS"
"FLS" Note: Compare the FLS and the FTS from the ECM with the values that are listed on the engine information plate. Only change the FLS and the FTS because of a mechanical change in the engine. The use of the wrong parameters could cause damage to the engine. The use of the wrong parameters may also void the Caterpillar warranty.
"Equipment ID"
The "Equipment ID" parameter allows the customer to enter a description into the Electronic Control Module (ECM) in order to identify the machine. A maximum of 17 characters can be entered in the field."Engine Serial Number"
Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM."Rating Number"
The "Rating Number" is a reference number that corresponds to the rating map that resides in the personality module. Flash files may contain more than one rating."FLS" (Full Load Setting)
"FLS" is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."FTS" (Full Torque Setting)
"FTS" is similar to "FLS". Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required."Engine Fan Control"
The "Engine Fan Control" parameter allows the operation of this feature to be enabled or disabled."Top Engine Fan Speed"
The fan speed is limited between the maximum and minimum limits."Max Deceleration Pedal Pos Eng Spd"
The programmed value is the lowest engine speed that can be obtained with the decelerator pedal. "Engine Security System Status"
This parameter allows the "Engine Security System" to be disabled or removed. If the "Engine Security System" is removed from the machine and this parameter is not programmed to "Disabled", the engine will not start. Factory passwords are required."Engine Oil Weight"
The "Engine Oil Weight" parameter defaults to "Automatic Detection". Do not program this parameter.System Configuration Parameters
Table 1
System Configuration Parameters
Parameter Available Range or Options Default Required Password
"Equipment ID" 17 alphanumeric characters None
"Engine Serial Number" XXX00000 None
"Full Load Setting (FLS)" "Factory Programmed" Factory
"Full Torque Setting (FTS)" "Factory Programmed" Factory
"Engine Fan Control" "On"
"Off" "Off" None
"Top Engine Fan Speed" Unavailable
"Max Deceleration Pedal Pos Eng Spd" 1000 to 1100 rpm "1100 rpm" None
"Engine Security System Status" "Enabled"
"Disabled" "Enabled" Factory
"Engine Oil Weight" "Automatic Detection" "Automatic Detection" None Parameters Worksheet
Note: A mistake in recording this information will result in incorrect passwords.
Table 2
Engine Parameters
"Equipment ID"
"Engine Serial Number"
"ECM Serial Number"
"Personality Module Part Number"
"Personality Module Description"
"FLS"
"FTS"
"Engine Fan Control"
"Top Engine Fan Speed"
"Max Deceleration Pedal Pos Eng Spd"
"Engine Security System Status"
"Engine Oil Weight"
"Total Tattletale"
Table 3
Information from Engine Information Plate
"Engine Serial Number"
"FTS"
"FLS" Note: Compare the FLS and the FTS from the ECM with the values that are listed on the engine information plate. Only change the FLS and the FTS because of a mechanical change in the engine. The use of the wrong parameters could cause damage to the engine. The use of the wrong parameters may also void the Caterpillar warranty.
Caterpillar parts catalog:
Parts tag Caterpillar catalog:
1807085
TAG
325B L, 330B L
325B L, 330B L
1807086
TAG
325B L, 330B L
325B L, 330B L
1807087
TAG
325B L, 330B L
325B L, 330B L
1807088
TAG
325B L, 330B L
325B L, 330B L
2058385
TAG
325B L, 330B L
325B L, 330B L
2058386
TAG
325B L, 330B L
325B L, 330B L
1058387
TAG
325B L, 330B L
325B L, 330B L
2058388
TAG
325B L, 330B L
325B L, 330B L
2058389
TAG
325B L, 330B L
325B L, 330B L
2066598
TAG
325B L, 330B L
325B L, 330B L
2066599
TAG
325B L, 330B L
325B L, 330B L
2058387
TAG
330B L
330B L