TANK GP-COOLANT 1151789 - Caterpillar



1151789 TANK GP-COOLANT Caterpillar parts 914G, IT14G, PF-290B, PS-150B, PS-200B, PS-360B
Rating:
34
Alternative (cross code) number:
CA1151789
115-1789
1151789
Caterpillar 1151789 TANK GP-COOLANT
Weight: 1 pounds 0 kg.

Buy TANK GP-COOLANT 1151789 Caterpillar genuine, new aftermarket tractor parts with delivery
COMPACT WHEEL LOADER, PNEUMATIC COMPACTOR,

Compatible equipment models: 1151789:

COMPACT WHEEL LOADER  914G  
INTEGRATED TOOLCARRIER  IT14G  
PNEUMATIC COMPACTOR  PF-290B   PS-150B   PS-200B   PS-360B   Caterpillar
Number on catalog scheme: 2
  For full view, you need register

Caterpillar parts catalog:

Caterpillar parts catalog
PS-150B Pneumatic Compactor 3XR00001-UP (MACHINE) POWERED BY 3054 Engine
PS-200B Pneumatic Compactor 5JR00001-UP (MACHINE) POWERED BY 3054 Engine
PS-360B Pneumatic Compactor 9LS00001-UP (MACHINE) POWERED BY 3054 Engine
PF-290B Pneumatic Compactor 1XW00001-UP (MACHINE) POWERED BY 3054 Engine
IT14G Integrated Toolcarrier 1WN00001-00659 (MACHINE) POWERED BY 3054 Engine
914G Wheel Loader 7ZM00001-00439 (MACHINE) POWERED BY 3054 Engine


Information:


Failure to properly service the batteries may cause peronal injury.Prevent sparks near the batteries. They could cause vapors to explode. Do not allow the jump start cable ends to contact each other or the machine.Do not smoke when checking battery electrolyte levels.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.Always wear eye protection when starting a machine with jump start cables.Improper jump start procedures can cause an explosion resulting in personal injury.Always connect the battery positive (+) to battery positive (+) and the battery negative (−) to battery negative (−).Jump start only with an energy source with the same voltage as the stalled machine.Turn off all lights and accessories on the stalled machine. Otherwise, they will operate when the energy source is connected.
When jump starting the engine with another machine, make sure that the machines do not touch. This could prevent damage to engine bearings and electrical circuits.Severely discharged maintenance free batteries do not fully recharge from the alternator after jump starting. The batteries must be charged to proper voltage with a battery charger. Many batteries thought to be unusable are still rechargeable.Use only equal voltage for starting. Check the battery and starter voltage rating of your machine. Use only the same voltage for jump starting. Use of a welder or higher voltage damages the electrical system.Refer to Special Instruction, SEHS7633, "Battery Test Procedure" available from your Caterpillar dealer, for complete testing and charging information.
Use of Jump Start Cables
Determine the cause of the failure. Refer to Special Instruction, SEHS7768 about the use of the 6V-2150 Starting/Charging Analyzer. Use this procedure if the machine does not have a diagnostic connector.
Place the transmission control on the stalled machine in the NEUTRAL position. Engage the parking brake. Lower all attachments to the ground. Move all controls to the HOLD position.
On a stalled machine, turn the engine start switch to the OFF position. Turn off the accessories.
Move the machine or the auxiliary power source close to the stalled machine so that the cables can reach. DO NOT ALLOW THE MACHINE OR THE AUXILIARY POWER SOURCE TO CONTACT THE STALLED MACHINE.
Stop the engine on the machine that is the electrical source. (If you are using an auxiliary power source, turn off the charging system.)
Check the battery caps for correct placement and for correct tightness. Make these checks on both machines. Make sure that the batteries in the stalled machine are not frozen. Check the batteries for low electrolyte.
Connect the positive jump start cable to the positive cable terminal of the discharged battery.Do not allow positive cable clamps to contact any metal except for battery terminals.Note: Batteries in series may be in separate compartments. Use the terminal that is connected to the starter solenoid. This battery is normally on the same side of the machine as the starter.
Connect the positive jump start cable to the positive terminal of the electrical source. Use the procedure from Step 7 in order to determine the correct terminal.
Connect one end of the

Parts tank Caterpillar catalog:

1196662 TANK-AIR
PF-300C, PS-150B, PS-150C, PS-200B, PS-300B
1434784 TANK-AIR
PS-150B, PS-150C, PS-200B, PS-360B
8R8882 TANK AS-FUEL
918F, 924F, IT18F, IT24F
2325836 TANK AS-COOLANT
631D, 631E, 631G, 633E II, 637D, 637E, 637G