4511408 TERMINAL AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4511408
451-1408
4511408
CA4511408
451-1408
4511408
Weight: 0.01 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Personal injury can result from hot coolant. Any contact with hot coolant or with steam can cause severe burns. Allow cooling system components to cool before the cooling system is drained.
Never weld or solder any charged components.
Note: A performance check of the air conditioning system must be made with a manifold gauge set. Refer to Testing and Adjusting, "Manifold Gauge Set (Refrigerant) - Install".Note: Before you conduct a performance test, refer to Testing and Adjusting, "Visual Inspection".Note: Refer to Testing and Adjusting, "Machine Preparation for Troubleshooting" before service work is performed on the air conditioning system.Note: The ambient temperature must be at least 21 °C (70 °F) in order to conduct the following test.
Install the manifold gauge set. Refer to Testing and Adjusting, "Manifold Gauge Set (Refrigerant) - Install" section.
Start the engine and operate the engine at 1000 rpm on LOW idle.
Push the main power switch on the climate control panel to ON.
Push the refrigerant compressor switch on the climate control panel to ON.
Set the air conditioner temperature control switch on the climate control panel to the maximum cooling position.
Set the fan switch on the climate control panel to the Hi position for maximum air flow.
In order to stabilize the system, continue to operate the system at 1000 rpm for a minimum of 10 minutes.
Adjust the engine speed to approximately 1300 to 1400 rpm. Record the readings on the gauge for discharge (high pressure), and on the gauge for suction (low pressure).
Compare the discharge and suction pressures on the manifold gauge set to the pressure ranges in Table 1. Use the pressure readings to determine if the system is functioning correctly for the current ambient temperature.
Table 1
Pressure Range (1)
Ambient Air Temperature
°C (°F) High Pressure Test Fitting
kPa (psi)(2) Low Pressure Test Fitting
kPa (psi)(3)
21 °C (70
Cat SIS web machinery list:
Parts terminal Caterpillar catalog:
4414831
TERMINAL
Caterpillar
Caterpillar
4414830
TERMINAL
Caterpillar
Caterpillar
4414822
TERMINAL
Caterpillar
Caterpillar
3603819
TERMINAL
Caterpillar
Caterpillar
3562508
TERMINAL-BATTERY
Caterpillar
Caterpillar
3503483
TERMINAL
Caterpillar
Caterpillar
4750707
TERMINAL AS
Caterpillar
Caterpillar
4750704
TERMINAL AS
Caterpillar
Caterpillar
4750701
TERMINAL AS
Caterpillar
Caterpillar
4750700
TERMINAL AS
Caterpillar
Caterpillar
4750699
TERMINAL AS
Caterpillar
Caterpillar
4641942
TERMINAL AS
Caterpillar
Caterpillar