9X8081 TERMINAL-RING Caterpillar parts
312D, 312D L, 315D L, 319D L, 319D LN, 320D, 320D L, 323D LN, 323D SA, 324D L, 325, 329D, 329D L, 329D LN, 336D, 336D L, 336D LN, 345B L, 345C L, 345D, 345D L, 345D L VG, 349D, 349D L, 350, 374D L, 37...
Rating:
Alternative (cross code) number:
CA9X8081
9X-8081
9X8081
CA9X8081
9X-8081
9X8081
Weight: 0.24 pounds 0 kg.
EXCAVATOR, WHEEL LOADER,
Compatible equipment models: 9X8081:
Information:
Full Load Setting:
Number representing fuel system adjustment made at the factory to "fine tune" the fuel system. Correct value for this parameter is stamped on the engine information ratings plate.Full Torque Setting:
Similar to Full Load Setting.Personality Module Code:
Code which prevents use of incorrect personality module for this engine. Each power rating family and emission certification has a different code associated with it. This code (stored in ECM) MUST match that in the personality module or a Diagnostic Code 56 will be generated. When rerating or installing a new ECM, programming this code to "0" will prompt the ECM to read and match its stored code to the personality module. Note that this code DOES NOT need to be programmed when a personality module is replaced, as long as the new module is of the same family. If the Personality Module is of a different family, then pistons, nozzles, etc. may need to be changed and the engine information plate should also be changed to reflect the rerate.Engine Serial Number:
Should be programmed to match the engine serial number stamped on the ratings plate. A new ECM is delivered with the engine serial number programmed to 0XX00000.Customer Specified Parameters
Customer Specified Parameters allow a customer to program some engine/system related parameters.Customer parameters may be changed repeatedly. Customer Passwords are required to change these parameters. Figure 2. on page 28 is an example of the ECAP screen displaying Customer Specified Parameters. The following is a brief description of the Customer Specified Parameters. Along with each are the minimum and maximum values for the parameter and the default value. The parameter value shown in bold is the setting which should be programmed if the feature is not used.Low Idle Engine Speed:
Minimum engine speed which may be programmed to any value between 600 rpm to 750 rpm range. Engine Location:
Used to program engine location (PORT or STBD). This parameter does not affect engine operation. However, it does affect CMS (Computerized Monitoring System) display panel. This parameter is used to display engine synchronization status, i.e. synchronized to PORT or STBD throttle on the CMS display.Trolling Speed:
Trolling speed can be programmed to any value from 900 to 1200 rpm. Passwords
Factory Passwords
Factory passwords are required to perform the following functions:1. Read Customer Passwords If the owner loses his customer passwords, he will not be able to program customer parameters. Using factory passwords, one can read customer passwords, then use those customer passwords to program customer parameters.2. Clear Certain Diagnostic Codes Only Diagnostic Codes 190-00 (Engine Overspeed Warning) and 23-02 (Excessive Engine Power) require factory passwords to clear once they are logged. Certain other codes require customer passwords. The majority of logged codes require no passwords to clear.To obtain factory passwords, proceed as if you already had the password. At some point, if factory passwords are truly needed, the ECAP will request factory passwords and will provide on its screen most of the information required to obtain the passwords.Customer Passwords
Customer passwords are required to change ANY customer
Number representing fuel system adjustment made at the factory to "fine tune" the fuel system. Correct value for this parameter is stamped on the engine information ratings plate.Full Torque Setting:
Similar to Full Load Setting.Personality Module Code:
Code which prevents use of incorrect personality module for this engine. Each power rating family and emission certification has a different code associated with it. This code (stored in ECM) MUST match that in the personality module or a Diagnostic Code 56 will be generated. When rerating or installing a new ECM, programming this code to "0" will prompt the ECM to read and match its stored code to the personality module. Note that this code DOES NOT need to be programmed when a personality module is replaced, as long as the new module is of the same family. If the Personality Module is of a different family, then pistons, nozzles, etc. may need to be changed and the engine information plate should also be changed to reflect the rerate.Engine Serial Number:
Should be programmed to match the engine serial number stamped on the ratings plate. A new ECM is delivered with the engine serial number programmed to 0XX00000.Customer Specified Parameters
Customer Specified Parameters allow a customer to program some engine/system related parameters.Customer parameters may be changed repeatedly. Customer Passwords are required to change these parameters. Figure 2. on page 28 is an example of the ECAP screen displaying Customer Specified Parameters. The following is a brief description of the Customer Specified Parameters. Along with each are the minimum and maximum values for the parameter and the default value. The parameter value shown in bold is the setting which should be programmed if the feature is not used.Low Idle Engine Speed:
Minimum engine speed which may be programmed to any value between 600 rpm to 750 rpm range. Engine Location:
Used to program engine location (PORT or STBD). This parameter does not affect engine operation. However, it does affect CMS (Computerized Monitoring System) display panel. This parameter is used to display engine synchronization status, i.e. synchronized to PORT or STBD throttle on the CMS display.Trolling Speed:
Trolling speed can be programmed to any value from 900 to 1200 rpm. Passwords
Factory Passwords
Factory passwords are required to perform the following functions:1. Read Customer Passwords If the owner loses his customer passwords, he will not be able to program customer parameters. Using factory passwords, one can read customer passwords, then use those customer passwords to program customer parameters.2. Clear Certain Diagnostic Codes Only Diagnostic Codes 190-00 (Engine Overspeed Warning) and 23-02 (Excessive Engine Power) require factory passwords to clear once they are logged. Certain other codes require customer passwords. The majority of logged codes require no passwords to clear.To obtain factory passwords, proceed as if you already had the password. At some point, if factory passwords are truly needed, the ECAP will request factory passwords and will provide on its screen most of the information required to obtain the passwords.Customer Passwords
Customer passwords are required to change ANY customer
Cat SIS web machinery list:
Parts terminal Caterpillar catalog:
1311470
TERMINAL AS
314D LCR, 321D LCR, 390D L, 587T, AP-1055D, AS3301C, BG-2455D, BG-260D, CP-44, CP-56, CP-64, CP-76, CS-44, CS-54, CS-56, CS-64, CS-74, PL83, PS-150C, RM-300
314D LCR, 321D LCR, 390D L, 587T, AP-1055D, AS3301C, BG-2455D, BG-260D, CP-44, CP-56, CP-64, CP-76, CS-44, CS-54, CS-56, CS-64, CS-74, PL83, PS-150C, RM-300
1385193
TERMINAL-BLADE
314C, 314D CR, 314D LCR, 315B, 345B L
314C, 314D CR, 314D LCR, 315B, 345B L
7Y5496
TERMINAL-BLADE
307, 307B, 311B, 312B, 314C, 314D CR, 314D LCR, 315, 315B FM L, 320B, 320B FM LL, 320N, 321B, 322, 325B, 325B L, 330, 345B L, 350, 5080
307, 307B, 311B, 312B, 314C, 314D CR, 314D LCR, 315, 315B FM L, 320B, 320B FM LL, 320N, 321B, 322, 325B, 325B L, 330, 345B L, 350, 5080
3408301
TERMINAL-BLADE
M318D MH, M322D MH
M318D MH, M322D MH
3408300
TERMINAL-BLADE
M318D MH, M322D MH
M318D MH, M322D MH
3408299
TERMINAL-BLADE
M318D MH, M322D MH
M318D MH, M322D MH
3727334
TERMINAL-RING
300.9D, 301.4C, 301.7D, 301.7D CR, 302.2D, 302.4D, 302.7D
300.9D, 301.4C, 301.7D, 301.7D CR, 302.2D, 302.4D, 302.7D
3727347
TERMINAL-RING
300.9D, 301.7D, 301.7D CR, 302.2D, 302.4D, 302.7D
300.9D, 301.7D, 301.7D CR, 302.2D, 302.4D, 302.7D
3725919
TERMINAL
300.9D, 301.4C, 301.7D CR, 302.7D
300.9D, 301.4C, 301.7D CR, 302.7D
3740677
TERMINAL AS-BATTERY
300.9D
300.9D
3757724
TERMINAL
300.9D, 301.4C, 301.7D, 302.2D, 302.4D, 302.7D
300.9D, 301.4C, 301.7D, 302.2D, 302.4D, 302.7D
3642790
TERMINAL AS
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH
M313D, M315D, M315D 2, M316D, M317D 2, M318D, M318D MH, M322D, M322D MH