7V5217 TIRE Caterpillar parts
Rating:
Alternative (cross code) number:
CA7V5217
7V-5217
7V5217
CA7V5217
7V-5217
7V5217
Weight: 1 pounds 0 kg.
Information:
Settings of the Injectors for the Autolube System
The controller of the autolube system is preset from the factory. The lubrication is dispensed at 15 minute intervals, and all of the injectors are preset at the full flow setting. There may be an excessive buildup of grease around some of the joints. As a result, the grease reservoir may need filling more frequently. The injectors for selected joints can be adjusted in order to reduce the flow of grease without adversely affecting the life of the pin. The injectors are set by the factory at the full flow setting. This setting is equivalent to 8 turns open. When the injectors are adjusted, the injectors should first be closed. Then, the injectors should be opened by the number of specified turns. The recommended settings for the injectors at each pin location are listed in Table 1.
Table 1
Pins Qty (Injectors) Settings (Turns)
A 0 8
B 2
C 2
E 3 5
F 2 2
G 1 8
H 1 2
J 1
K 0 8
L 4 2
X 2 8
Y 0 8 Note: By using the above settings, the buildup of grease will be reduced. The interval between refills of the reservoir will be extended to approximately 250 hours. Grease levels in the reservoir must be checked in order to ensure an uninterrupted flow.Timer Operation
Autolube systems must be adjusted before being put into use to ensure each joint gets the appropriate amount of grease. Different applications require frequency, volume, and proportioning adjustments from the recommended or factory settings.Autolube settings must be monitored and adjusted as needed to account for changes in application, temperature, grease type, and NLGI grade.
Illustration 2 g01239276
(6) Access plug Remove access plug (6) on the front of the pump in order to access the timer control. The timer control group consists of the following:
Manual lubrication switch
OFF timer rotary switch
ON timer rotary switch
Power ON LED
Pump ON LED
Illustration 3 g01238978
Timer control
(7) OFF timer switch
(8) ON timer switch
(9) Power ON LED.
(10) Pump motor ON LED
(11) Push button for manual lubrication OFF timer switch (7) can be adjusted to 15 values. See Table 1 for the time interval for each value.ON timer switch (8) can be adjusted to 15 values. See Table 1 for the time interval for each value.LED (9) is marked "battery". This LED will illuminate when power is sent to the pump control.LED (10) is marked "motor". This LED will illuminate when the pump is pumping lubricant.Press push button (11) for 2 seconds. This process will initiate a manual lubrication cycle.The OFF position of the timer begins accumulating time when the ignition switch closes. When the OFF position of the timer reaches the preset value, the pump will turn ON. The pump remains activated for the time period that is preset on the ON timer.When the ignition is turned OFF, the used time is saved for an unlimited duration.Turn the ignition to the ON position. The automatic lubrication operation will finish the cycle time.Note: Do not use the zero setting that is located on the timer switches.Note: The factory setting
The controller of the autolube system is preset from the factory. The lubrication is dispensed at 15 minute intervals, and all of the injectors are preset at the full flow setting. There may be an excessive buildup of grease around some of the joints. As a result, the grease reservoir may need filling more frequently. The injectors for selected joints can be adjusted in order to reduce the flow of grease without adversely affecting the life of the pin. The injectors are set by the factory at the full flow setting. This setting is equivalent to 8 turns open. When the injectors are adjusted, the injectors should first be closed. Then, the injectors should be opened by the number of specified turns. The recommended settings for the injectors at each pin location are listed in Table 1.
Table 1
Pins Qty (Injectors) Settings (Turns)
A 0 8
B 2
C 2
E 3 5
F 2 2
G 1 8
H 1 2
J 1
K 0 8
L 4 2
X 2 8
Y 0 8 Note: By using the above settings, the buildup of grease will be reduced. The interval between refills of the reservoir will be extended to approximately 250 hours. Grease levels in the reservoir must be checked in order to ensure an uninterrupted flow.Timer Operation
Autolube systems must be adjusted before being put into use to ensure each joint gets the appropriate amount of grease. Different applications require frequency, volume, and proportioning adjustments from the recommended or factory settings.Autolube settings must be monitored and adjusted as needed to account for changes in application, temperature, grease type, and NLGI grade.
Illustration 2 g01239276
(6) Access plug Remove access plug (6) on the front of the pump in order to access the timer control. The timer control group consists of the following:
Manual lubrication switch
OFF timer rotary switch
ON timer rotary switch
Power ON LED
Pump ON LED
Illustration 3 g01238978
Timer control
(7) OFF timer switch
(8) ON timer switch
(9) Power ON LED.
(10) Pump motor ON LED
(11) Push button for manual lubrication OFF timer switch (7) can be adjusted to 15 values. See Table 1 for the time interval for each value.ON timer switch (8) can be adjusted to 15 values. See Table 1 for the time interval for each value.LED (9) is marked "battery". This LED will illuminate when power is sent to the pump control.LED (10) is marked "motor". This LED will illuminate when the pump is pumping lubricant.Press push button (11) for 2 seconds. This process will initiate a manual lubrication cycle.The OFF position of the timer begins accumulating time when the ignition switch closes. When the OFF position of the timer reaches the preset value, the pump will turn ON. The pump remains activated for the time period that is preset on the ON timer.When the ignition is turned OFF, the used time is saved for an unlimited duration.Turn the ignition to the ON position. The automatic lubrication operation will finish the cycle time.Note: Do not use the zero setting that is located on the timer switches.Note: The factory setting
Caterpillar parts catalog:
Parts tire Caterpillar catalog:
7K0226
TIRE
Caterpillar
Caterpillar
6K2305
TIRE
Caterpillar
Caterpillar
6C7711
TIRE
Caterpillar
Caterpillar
6C2390
TIRE
Caterpillar
Caterpillar
5V4216
TIRE
Caterpillar
Caterpillar
5V3136
TIRE
Caterpillar
Caterpillar
4187028
TIRE & RIM GP
Caterpillar
Caterpillar
4187020
TIRE & RIM GP
Caterpillar
Caterpillar
3990971
TIRE & RIM AR
Caterpillar
Caterpillar
3771324
TIRE & RIM AR
Caterpillar
Caterpillar
3771321
TIRE & RIM AR
Caterpillar
Caterpillar
8K8667
TIRE-23.5 X 25 ROCK TREAD TUBELESS
Caterpillar
Caterpillar