3689989 TOOL-MOIL POINT Caterpillar parts
Rating:
Alternative (cross code) number:
CA3689989
368-9989
3689989
CA3689989
368-9989
3689989
Weight: 253 pounds 114 kg.
Information:
Illustration 1 g01158925
This diagnostic code is associated with the solenoid valve for for raising the left end of the blade. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of this diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2160 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active the hydraulic control system will default to the "Auto Not Allowed" state.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-67 (wire K813-BU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-67 (K813-BU) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 2160 FMI 03 is active.Expected Result:The CID 2160 FMI 03 is active.Results:
YES - The CID 2160 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Module - Replace".STOP
NO - The CID 2160 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Caterpillar parts catalog:
Parts tool Caterpillar catalog:
3689988
TOOL-BLUNT
Caterpillar
Caterpillar
4533209
TOOL GP
Caterpillar
Caterpillar
4533208
TOOL GP
Caterpillar
Caterpillar
5172263
TOOL GP-WHEEL INSTALLATION
Caterpillar
Caterpillar
5110252
TOOL-CHISEL
Caterpillar
Caterpillar
5110250
TOOL-MOIL POINT
Caterpillar
Caterpillar
5233115
TOOL GP
Caterpillar
Caterpillar
5233114
TOOL GP
Caterpillar
Caterpillar
5107391
TOOL
Caterpillar
Caterpillar
4603603
TOOL AS
Caterpillar
Caterpillar
4164398
TOOL-MOIL POINT
Caterpillar
Caterpillar
3747055
TOOL-MOIL POINT
Caterpillar
Caterpillar